• 500/5A Measurement and Protection Level Clamp Current Transformers Production
  • 500/5A Measurement and Protection Level Clamp Current Transformers Production
  • 500/5A Measurement and Protection Level Clamp Current Transformers Production
  • 500/5A Measurement and Protection Level Clamp Current Transformers Production
  • 500/5A Measurement and Protection Level Clamp Current Transformers Production
  • 500/5A Measurement and Protection Level Clamp Current Transformers Production

500/5A Measurement and Protection Level Clamp Current Transformers Production

Application: Electronic, Instrument, Position Sensor, Audio, Lighting
Type: Current Transformer
Phase: Single
Operation Condition: Indoor
Usage: M & P
Winding Form: Multilayer Honeycomb Type
Customization:
Gold Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
LZCK530-10
Insulating Medium
Epoxy Resin
Installation
Busbar Type
Magnetic Circuit Structure
Combined Type
Voltage Transformation Principle
Electromagnetic Type
Class
0.2s, 0.2, 0.5s, 0.5
Types
M & P Current Transformers Production
Raito
500/5A
Color
Red
Diameter
50mm
Weight
2.1kg
Design Lifes
30years
Standard
IEC60044-1; IEC 61869-2; ANSI C57.13; Ntc 2205; GB
Fs
<10
Burden
<20va
Transport Package
Standard Export Box
Specification
LZCK530-10
Trademark
GFUVE
Origin
Beijing China
Production Capacity
20000PCS/Month

Product Description

GFUVE China manufacturer supply 500/5a measurement and protection level clamp current transformers production
500/5A Measurement and Protection Level Clamp Current Transformers Production
LZCK series Cast Resin Straight-Through Current Transformer is suitable for current measurement and microcomputer protection of electrical equipment in 10KV and 35KV AC power system. It is widely used in not only compact fully insulated ring network switchgears such as ABB-Safe Ring/Safe Plus, Unstitch, Schneider RM6, SM6, Siemens 8DJ10/8DH10, Simosec, FBX, Fluokit, Omar Garbo GA, GAE; SEL TPS(Q); VEI Unifluorc; Eaton SVS/12 ring network, but also cable distribution boxes because of its small size, light weight, operable and convenient installation. It is very convenient that the transformer can be directly installed at the inlet and outlet cables. This 500/5a current transformers production is supplied by China manufacturer GFUVE ELECTRONIC MADING.
New magnetic material is taken to be the core of the current transformer, which has high magnetic permeability, low saturation magnetization and good stability. Therefore, the measuring accuracy is higher and the instrument security factor is lower. Since the high quality silicon processed by advanced technology is taken to be the core of the protection windings, which assured the accuracy limit factor is higher.
The semicircular ring core and secondary windings are vacuum poured by high quality epoxide resin in the fire retardant plastic casing, which has the characteristic of moisture proof, stable performance and dispensing with maintenance.Small size, light weight, small footprint, fixed in the ring network switchgear cable.The cable can cross the current transformer through its internal poles quickly and uniformly.
The Cast Resin Straight-Through Current Transformer can be divided several kinds according to the various current ratio, accuracy and rated loads. The specific parameters are showed in the corresponding to each model parameter tables.
MODEL MEANING
WIRING DIAGRAMS
P1, P2 is primary polarity terminal, S1, S2 is secondary polarity terminal.
P2, S2 is homonymous terminals (subtractive polarity).
PARAMETERS
Technical parameters  
Standards IEC60044-1; IEC 61869-2; NTC 2205; GB1208-2006;ANSI C57.13
Rated primary current 30-600A
Rated load ≤20VA
Rated frequency 50Hz or 60Hz
Rated secondary current 5A or 1A
Rated short-time thermal current 40kA, 1S
Rated continuous thermal current 120%I1n
Secondary winding power-frequency voltage 3kV, 1min
Instrument security factor FS ≤10
Mechanical parameters  
Dimensions (W×D×H) (mm) φ45xφ120x65
Weight (kg) 2.1
Operating conditions  
Operating temperature -35°C to +55°C
Daily average temp <+40°C
Storage temperature -40°C to +70°C
Altitude <3500 meters
Operating conditions - continued  
Condition No existence of severely begrimed, erosive and radioactive gas in the air. Permission of long-term operation under rated current.
TYPE SELECTION 
Type LZCK530-10 LZCK530-10 LZCK530-10
Purpose Measuring current transformer Protection current transformer Double winding current transformer
Rated primary current (AMP) Accuracy class and rated load(VA) Accuracy class and rated load(VA) Composite accuracy class and rated load(VA)
0.2S 0.2 0.5 10P20 10P15 10P10 0.2S 0.5 10P15 10P10
30     2              
40     2.5              
50     3.75     2        
75   3.75 5   2 3.75        
100 2.5 5 7.5   2.5 3.75        
150 5 7.5 10 2.5 3.75 6.25 2.5 3.75   2.5
200 7.5 10 15 3.75 5 7.5 5 7.5   3.75
300 10 15 20 5 7.5 10 7.5 10 2.5 5
400 15 20 25 6.25 7.5 15 10 12.5 3.75 5
500 20 25 25 6.25 7.5 15 15 15 3.75 5
600 20 30 30 7.5 10 20 15 20 3.75 7.5
http://guangfuhui.en.made-in-china.com