• Epoxy Resin Three Phase Protection 5p20 Zero Phase Current Transformer
  • Epoxy Resin Three Phase Protection 5p20 Zero Phase Current Transformer
  • Epoxy Resin Three Phase Protection 5p20 Zero Phase Current Transformer
  • Epoxy Resin Three Phase Protection 5p20 Zero Phase Current Transformer

Epoxy Resin Three Phase Protection 5p20 Zero Phase Current Transformer

Application: Instrument
Type: Current Transformer
Phase: Three
Operation Condition: Indoor
Usage: Protection, Measurement
Winding Form: Multilayer Honeycomb Type
Samples:
US$ 200/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
LZCK2502-10
Insulating Medium
Epoxy Resin
Installation
Active Type
Magnetic Circuit Structure
Combined Type
Voltage Transformation Principle
Electromagnetic Type
Names
5p20 Zero Phase Current Transformer
Applications
Substation Protection Device
Weights
7.5kg
Material
Epoxy Resin
Diameter
160mm, 140mm, 120mm
Burden
2.5va-30va
Color
Red and Black
Transport Package
Standard Export Carton Packaging
Specification
100/1A 5P20
Trademark
GFUVE
Origin
Beijing, China
HS Code
8470501000
Production Capacity
50000sets/Month

Product Description

LZCK2502-10 Epoxy resin three phase protection 5P20 zero phase current transformer For protection device

LZCK2502-10 protection 5P20 zero phase current transformer is suitable for current measurement and microcomputer protection of electrical equipment in 10KV and 35KV AC power system. It is widely used in compact fully insulated ring network switchgears such as ABB-Safe Ring/Safe Plus...and cable distribution boxes. The current transformer can be directly installed at the inlet andoutlet cables.The slice is imported silicon material. Thesemicircular ring core and secondary windings arevacuum poured by insulated resin.

100A Zero Phase Current Transformer The 100A zero phase current transformer is applied to small current monitoredcircuit. When the monitored circuit fails, it can turn 100A input current into zero phase current ranging from 10mA to 1,000A and control theswitching of circuits.

Zero phase current transformer which detects the difference between the currents flowing in anumber of conductors. The current flowing to a load must equal the current flowing back from theload. If this is not the case, a potentially dangerous residual current will be flowing somewhere in theinstallation.
 

WIRING DIAGRAMS

Epoxy Resin Three Phase Protection 5p20 Zero Phase Current Transformer
 

P1, P2 is primary polarity terminal, S1, S2 is secondary polarity terminal.
P2, S2 is homonymous terminals (subtractive polarity).

PARAMETERS

Technical parameters
Standards IEC60044-1; IEC 61869-2; NTC 2205; ANSI C57.13; GB1208-2006
Rated primary current 50-3000A
Rated load ≤30VA
Rated frequency 50Hz or 60Hz
Rated secondary current 5A or 1A
Rated short-time thermal current 40kA, 1S
Rated continuous thermal current 120%I1n
Secondary winding power-frequency voltage 3kV, 1min
Instrument security factor FS≤10
Mechanical parameters
Dimensions (W×D×H) (mm) φ160xφ225x100
Weight (kg) 7
Operating conditions
Operating temperature -35°C to +55°C
Daily average temp <+40°C
Storage temperature -40°C to +70°C
Altitude <3500 meters
Condition No existence of severely begrimed, erosive and radioactive gas in the air. Permission of long-term operation under rated current.

SELECTION GUIDE

Type LZCK2500-10 LZCK2500-10
Purpose Measuring current transformer Protection current transformer
Ratio Accuracy class and rated load(VA) Accuracy class and rated load(VA)
I1/I2 0.5 1 3 10P15 10P10 10P5
300/5 5 5 5 2.5 5 7.5
400/5 5 5 5 2.5 5 7.5
500/5 5 7.5 7.5 5 7.5 10
600/5 5 7.5 7.5 5 7.5 10
800/5 10 10 10 5 10 15
1000/5 10 15 15 5 10 15
1200/5 15 20 20 10 15 20
1500/5 15 20 20 10 15 20

SELECTION GUIDE

 Model Primary rated current Rated load Aperture (mm) Description (mm) Weight (kg) Material Water-proof
LZCK-55 100-1500A ≤10VA φ55 180×138×52 2 ABS+Resin  IP65
LMCK185-10 300-3000A ≤25VA φ185 350×283×55 4.5 ABS+Resin  IP65
LZCK310-10 300-600A ≤10VA φ50 φ50 x φ110 x 32 1 Resin silicon case (option)
LZCK322-10 30-600A ≤10VA φ50 φ50 x φ110 x 52 1.6 Resin silicon case (option)
LZCK350-10 20-600A ≤25VA φ50 φ50 x φ110 x 105 3.1 Resin silicon case (option)
LZCK720-10 20-1000A ≤25VA φ60 φ80 x φ110 x 50 2.1 Resin silicon case (option)
LZCK2500-10 50-5000A ≤20VA φ160 φ160 x φ225 x 100 7 Resin silicon case (option)
LZCG530-10 30-600A ≤20VA φ45 φ45 x φ120 x 65 2.1 Resin silicon case (option)
LZCG930-10 100-1500A ≤25VA φ60 φ60 x φ155 x 60 3.6 Resin silicon case (option)
LZCT722-10 20-600A ≤10VA φ82 φ82 x φ130 x 55 2.3 Resin silicon case (option)

ORDERING INFORMATION

Be sure to the type, current ratio, accuracy class, rated load and use of the products when you plan to make a order. Special specifications could be customized.All kinds of different specifications and parameters current transformers can be made according to your needs.

PHOTOS

Epoxy Resin Three Phase Protection 5p20 Zero Phase Current Transformer




 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now