• High Precision Electrical Three Phase Harmonic Power Source Calibrator
  • High Precision Electrical Three Phase Harmonic Power Source Calibrator
  • High Precision Electrical Three Phase Harmonic Power Source Calibrator
  • High Precision Electrical Three Phase Harmonic Power Source Calibrator
  • High Precision Electrical Three Phase Harmonic Power Source Calibrator
  • High Precision Electrical Three Phase Harmonic Power Source Calibrator

High Precision Electrical Three Phase Harmonic Power Source Calibrator

After-sales Service: 24 Hour Service
Warranty: 3 Years
Application: Electromagnetic Instrument, Electrical Test Equipment
Power: Electricity
Certification: FDA, CE, IAF, CCC
Voltage Output: 0-600V AC
Samples:
US$ 29868/Set 1 Set(Min.Order)
| Request Sample
Customization:
Gold Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
GF303D
Current Output
0-120A AC
LCD Display
With LCD Display
Customized
Customized
AC Voltage Output
57.7 V, 100 V, 220 V, 380 V; Range Switch Automati
AC Current Output
0.1, 0.25A, 0.5, 1A, 5A, 10A, 20A, 100A
Frequency
40 Hz ~ 70 Hz
Power Factor
-1 ~ 0 ~ + 1
Harmonic Times
2~128
Weight
18 Kg
Volume and Weight
450 mm X 380 mm X 160 mm
Working Temperature
0~50′c
Types
Three Phase Phantom Load Power Source
Accuracy
0.05%
Key Word
Electrical Power Calibrator
Name
High Precision Power Source
Transport Package
Standard Export Carton
Specification
CE, ISO9001: 2008, IEC
Trademark
GFUVE
Origin
Beijing China
HS Code
9030849000
Production Capacity
200sets/Month

Product Description

GF303D High Precision Electrical Three Phase Harmonic Power Source Calibrator

The GF303D electrical power calibrator can also be used to type test 0.1% to 2% energy meters. Choose the GF303D electrical power calibrator when you need the highest accuracy available for calibrating secondary standard meters, energy revenue meters and type test applications. The model GF303D three phase power source is electric AC voltage, current and power calibrator for calibration of power meters, power transducers, current meter, voltage meter and generally all kinds of power measuring devices. AC voltage, current, power functions have calibrated phase shift in frequency range from 40 Hz to 70Hz with resolution as good as 0.001 Hz. It have three channel voltage and three phase current independent output, any programmable setting, low phase shift, high stability 0.01%/1min, as standard three phase voltage source, three phase current source and three phase power source , is a high precision portable calibration tool in electrical laboratory.
FEATURES
To set up and take the load regulation of voltage, current, phase angle, frequency and power factor, also can be used as AC current source, AC voltage source or power source.
To set 2-128 times of the amplitude and phase harmonics, and it can be added to the base wave in every harmonic output.
Frequency value is adjustable (AB and phase C).
Voltage, current output a wide range, big power, high stability, waveform distortion degree is small.
Strong with load ability, but it can take capacitive, sensibility, resistance of composite type load or load and load regulation is higher than 0.01%.
To apply the 32 bit MPU + DSP + FPGA, powerful flexible.
To use hardware PID, fast response, the change of load will not cause output volatility.
Industrial frequency waves as high as 50000 points a week of the wave kneading, signal output without filter, precise output waveform, the harmonic output precision, harmonic distortion degree is small.
Range switching automatically
To use software calibration, simple operation, stable and reliable.
To have big screen, 320 x 240 LCD display, Chinese or English interface, operating simply.
To have perfect over-current, over-voltage, heat, a shorts-and-opens, overload protection, failure detection automatically.
With RS232 interface, and PC connection
To take place machine software, it can be output through the PC software program.
PARAMETERS

Electrical parameters
Accuracy class  0.05%, 0.1%
Power supply Single phase AC 85V-265V, 50/60 Hz
AC Voltage output
Range (U1, U2, U3 phase) 57.7V/100V/220V/380V, switch automatically (max 420V)
Adjustment resolution 0.01%, 0.1%, 1%, 10%,
Accuracy 0.05% RG
Stability 0.005% RG/1min
Distortion degree better than 0.1% (not capacitive load)
Load Capacity 25VA
Full load regulation rate Less than 0.01% RG
Full load regulation time Less than 1mS
Temperature drift 8 PPM / °C
Long-term stability 60 PPM/year
AC Current output
Range (I1, I2, I3 phase) 0.1/0.25A/0.5A/1A/5A/10A/20A, switch automatically
Adjustment resolution 0.01%, 0.1%, 1%, 10%, 
Accuracy 0.05% RG
Stability 0.005% RG/1min
Distortion degree better than 0.1% (not capacitive load)
Load capacity 25VA
Full load regulation rate Less than 0.01% RG
Full load regulation time Less than 1mS
Temperature drift 8 PPM/°C
Long-term stability 60 PPM/year
Power output
Active power accuracy 0.05%
Reactive power accuracy 0.1%
Stability 0.005% RG/1min
Phase
Range 0°-359.99°
Adjustment resolution 0.01°, 0.1°, 1°, 10°
Accuracy 0.03°
Power factor  
Adjusting range -1 to 0 to +1
Resolution 0.0001
Accuracy 0.0005
Frequency
Range 40-65Hz or 40-400Hz (option)
Adjustment resolution 0.001Hz, 0.01Hz, 0.1Hz, 1Hz
Accuracy 0.002Hz
Temperature drift 0.5PPM/°C
Long-term stability 4 PPM/year
Harmonic
Harmonic times 2-128
Adjustment resolution 0.1% (compared with fundamental wave)
Harmonic content (compared with fundamental wave)
Voltage ≤40%
Current ≤40%
Phase 0°-360°
Capacitive load capacity
0 - 280 V 1uF 
280 - 420 V 0.6uF
Mechanical parameters
Dimensions (W×D×H) (mm) 450x380x160
Weight (kg) 18
Environmental conditions
Working temperature 0°C to 40°C
Storage conditions -30°C to 60°C
Relative humidity ≤85%
SELECTION GUIDE

No.
Accuracy Voltage range Current range Weight Remark
3030601 0.10% 0-264V 0-6A 12KG
3030605 0.05% 0-264V 0-6A 12KG
3031201 0.10% 0-420V 0-12A 13.5KG
3031205 0.05% 0-420V 0-12A 13.5KG
3032001 0.10% 0-420V 0-20A 18KG
3032005 0.05% 0-420V 0-20A 18KG
303H0601 0.10% 0-300V 0-6A 15KG XP system
303H0605 0.05% 0-300V 0-6A 15KG XP system
303H1201 0.10% 0-420V 0-12A 18KG XP system
303H1205 0.05% 0-420V 0-12A 18KG XP system
303H2001 0.10% 0-420V 0-20A 20KG XP system
303H2005 0.05% 0-420V 0-20A 20KG XP system
 