Phantom Load, Single Phase Phantom Load, Single Phase Source manufacturer / supplier in China, offering Program-Controlled Single-Phase Standard Phantom Load Source, Program-Controlled Three Phase Portable Voltage and Current Source, Transducer Test, Gf302 Portable Multifunction Instrument Calibrator and so on.

(/ )

Supplier Homepage Product Power Sources single phase source Program-Controlled Single-Phase Standard Phantom Load Source

Program-Controlled Single-Phase Standard Phantom Load Source

FOB Price: US $125,858 / Piece
Min. Order: 1 Set
Min. Order FOB Price
1 Set US $125,858/ Piece
Get Latest Price
Production Capacity: 200PCS/Month
Transport Package: Standard Export Carton
Payment Terms: L/C, T/T, D/P, Paypal, Money Gram, Western Union

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: GF101
  • AC Current Output: 0.1/ 0.25A / 0.5A / 1A / 5A / 10A / 20A / 50A / 10
  • Frequency: 40Hz ~ 65Hz
  • Working Temperature: 0 ~ 40′c
  • Type: Single Phase Phantom Load
  • Trademark: GFUVE
  • Origin: Beijing China
  • AC Voltage Output: 57.7V / 100V / 220V / 380V / 750V, Range Switch Au
  • Phase Angle: 0 ~ 359.99°
  • Size: 420mmx320mmx155mm
  • Weight: 12kg
  • Certificate: CE, ISO9001:2008,IEC
  • Specification: CE, ISO9001: 2008, IEC
  • HS Code: 9030849000
Product Description
Application of Electrical and electronic test equipment GF101 program-controlled single-phase standard source, with excellent working performance, CE, ISO9001: 2008, IEC approved, with three years quality warranty
It is suitable for power department, measuring department, quality control department, research units, and institutions of higher learning, and electric energy meter, power distribution terminals, power supply management, load control, power quality, reactive power compensation device and production of the enterprise and so on. It can be as single phase voltage source, current source and power source.
Main Functions and Features
To set up and take the load regulation of voltage, current, phase and frequency of the power factor;
To be set to 2 ~ 128 times of the amplitude and phase harmonics, and it can be added to the base wave in every harmonic output;
Voltage, current output a wide range, big power, high stability, waveform distortion degree is very small;
To have strong with load ability, and take capacitive, sensibility, resistance of composite type load or load and load regulation is higher than 0.01%;
To apply the 32 bit MPU + DSP + FPGA, powerful flexible;
To use hardware PID, fast response, the change of load will not cause output volatility;
Industrial frequency waves as high as 50000 points a week of the wave kneading, signal output without filter, precise output waveform, the harmonic output precision, harmonic distortion degree is small;
Range switching automatically;
To use software calibration, simple operation, stable and reliable;
To have the big screen, 320 X 240 LCD display, Chinese or English interface, operating simplely;
To have perfect over-current, over-voltage, heat, a shorts-and-opens, overload protection, automatic failure detection;
With RS232 interface, and PC connection;
To take place machine software, it can be output through the PC software of program.
Technical Data
Electrical parameters
Accuracy class 0.05%, 0.1%
Power supplySingle phase AC 85-265V, 50/60 Hz
AC Voltage output
Range57.7V / 100 V / 220V / 380V, Switch automatically (max 500V)
Adjustment resolution0.01%, 0.1%, 1%, 10%,
Accuracy0.05% RG
StabilityBetter than 0.01% RG/1min
Distortion degreeBetter than 0.1% (not capacitive load)
Load capacity40VA
Full load regulation rateLess than 0.01% RG
Full load regulation timeLess than 1ms
Temperature drift8 PPM/°C
Long-term stability60 PPM/year
AC Current output
Range0.1A / 0.25A / 0.5A / 1A / 5A / 10A / 20A / 50A / 100A, 
Switch automatically
Adjustment resolution0.01%, 0.1%, 1%, 10%, 
Accuracy0.05% RG
StabilityBetter than 0.01% RG/1min
Distortion degreeBetter than 0.1% (not capacitive load)
Load capacity40VA
Full load regulation rateLess than 0.01% RG
Full load regulation timeLess than 1mS
Temperature drift8 PPM/°C
Long-term stability60 PPM/year
Power output
Active power accuracy0.05% or 0.1%
Reactive power accuracy0.1% or 0.2%
StabilityBetter than 0.01% RG/1min
Phase
Range0°-359.99°
Adjustment resolution0.01°, 0.1°, 1°, 10°
Accuracy0.03°
Frequency
Range40-65 Hz
Adjustment resolution0.001 Hz, 0.01 Hz, 0.1 Hz, 1Hz
Accuracy0.002 Hz
Temperature drift0.5 PPM/°C
Long-term stability4 PPM/year
Harmonic
Harmonic times2nd-63th
Adjustment resolution0.1% (Compared with fundamental wave)
Harmonic content (Compared with fundamental wave)
Voltage≤40%
Current≤40%
Phase0°-360°
Mechanical parameters
Dimensions (W×D×H) (mm)420x320x155
Weight (kg)12
Environmental conditions
Operating temperature0°C to 40°C
Storage conditions-30°C to 60°C
Relative humidity≤85%