• Test Bench Three Phase Multifunction Calibrator
  • Test Bench Three Phase Multifunction Calibrator
  • Test Bench Three Phase Multifunction Calibrator
  • Test Bench Three Phase Multifunction Calibrator
  • Test Bench Three Phase Multifunction Calibrator
  • Test Bench Three Phase Multifunction Calibrator

Test Bench Three Phase Multifunction Calibrator

After-sales Service: 24 Hours Service
Warranty: 3 Years
Max Diameter of Workpiece: No
Mass Scope of Workpiece: No
Type: Electrical Calibration
Maxcapacity: No
Customization:
Gold Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
GF302C
Accuracy Grade
0.05
Load Way
Electronic Load
Loading Method
Dynamic Load
Display
Digital
Control
Computer Control
Weight
20kg
Power Source
AC380V
Oil Cylinder Position
No
GF302c
Multifunction Instrument Test Equipment
AC Voltage Signal Output
50V--800V
AC Current Signal Output
0.5A--20A
Voltage / Current Harmonic Output
2--31st
Operating Temperature
0 ~ 40°
Dimensions
460 mm X 430 mm X 185 mm
Frequency
45--65Hz
Adjust Fineness
5 X 10-5
Transport Package
Aluminium Alloy Box
Specification
EN 61010-1, CE, ISO9001: 2008, IEC
Trademark
GUFVE
Origin
Beijing, China
Production Capacity
200PCS/ Month

Product Description

GF302C multifunction instrument test equipment
Test Bench Three Phase Multifunction Calibrator
Test Bench Three Phase Multifunction Calibrator
Test Bench Three Phase Multifunction Calibrator

1. Function: Measure Voltage, Current, Vector, Waveform Distortion, Harmonic, Power, Phase, Power Factor, Frequency, Energy Error.
2. Wide range: Voltage 60V-480V, Current 1A, 10A, Auto switching range/Manual switching range.
3. Complete software calibration, to eliminate the drawback of hardware calibration.
AC power output
Accuracy: 0.05% RG Stability: 0.01% / 1 min
Frequency
Frequency range: 45.000 ~ 65.000 Hz Resolution: 0.001 Hz Accuracy: 0.01 Hz
Power factor output
Adjusting range: -1~0~1 Adjust fineness: 0.0001 Accuracy: 0.0005
Phase angle
Scope: 0.00 ° ~ 359.99 ° Resolution: 0.01 ° Accuracy: 0.05 °
Voltage/Current harmonic output
2~31st
DC measurements
DC voltage measurement range: 0 ~ ± 24V DC current measurement range: 0 ~ ± 24mA
Measurement accuracy: 0.01% RG
Watt-hour meter measuring the integrated error
Active power: 0.05% Reactive power: 0.1%
Environmental conditions
Working temperature: 0 ~ 40° Relative humidity: ≤ 85%
Work power
Single phase AC 220 V± 10%, Frequency 50/60 Hz
Volume and weight
Size: 460 mm x 430 mm x 185 mm
Weight: About 20 Kg
Our Service
We are able to provide Complete set of scan head according to your detailed requirements, please contact me directly by skype or send inquiries to me at any time! We are always in a position to quote you the most advantageous price for higher quality merchandise. ^_^

 
  AC voltage output  AC current output  DC voltage output  DC current output 
Range 50V---600V 0.5A---20A 75V---1000V 0.5A---20A
Adjusting range  (0-120) % RG  (0-120) % RG   (0-120) % RG   (0-120) % RG 
Adjust fineness 0.01% RG  0.01% RG  0.005% RG 0.005% RG
Accuracy 0.05% RG  0.05% RG  0.05% RG 0.05% RG
Stability 0.01% / 1 min  0.01% / 1 min   0.01% / 1 min  0.01% / 1 min 
Load capacity 25 VA   25 VA   25 VA   25 VA 
Output distortion degree ≤0.3% or (linear load)  ≤0.3% or (linear load)     

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now