• Current Transformer Turns Ratio Test Analyzer Set
  • Current Transformer Turns Ratio Test Analyzer Set
  • Current Transformer Turns Ratio Test Analyzer Set
  • Current Transformer Turns Ratio Test Analyzer Set
  • Current Transformer Turns Ratio Test Analyzer Set

Current Transformer Turns Ratio Test Analyzer Set

Application: Thermal Power, Mechanical Instrument, Time Frequency Instrument, Electromagnetic Instrument
Power: Electricity
Certification: FDA, CE, IAF, CCC
Voltage Output: 100V
Current Output: 5A
LCD Display: With LCD Display
Customization:
Gold Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
GF1061
Customized
Customized
Accuracy Class
0.05%, 0.1%
Key Words
11kv Current Transformer Test Set
Key Word
11kv Current Transformer Test
Model
1000A CT Testing
Output Voltage
0-100vrms
Output Current
0-5arms (20A Peak-Value)
Output Power
0-400 Va (1500 Vapeak)
Equivalent Excitation Voltage
≤5000V
Resistance Measurement
0.1-300Ω
Weight (Kg)
10
Transport Package
Standard Export Wooden Box
Trademark
GFUVE
Origin
Beijing, China
Production Capacity
200pieces/Day

Product Description

Current Transformer Turns Ratio Test Analyzer Set
Product description
GF1061 portable CT PT analyzer is mainly used for field or lab testing, it can finish the measurements (M) and protection (P) class CT, PT and TYP class CT. Adopt 7 inch touch TFT LCD, self-equipped mini type printer supporting field printing; supporting to use USB flash disk to dump data. The CT PT Analyzer is the most complete and easy-to-use testing system for protection and metering CTs according to IEEE and IEC standards.
Features
1. Steady and transient state characteristic tests of various types of CT/PT
2. The use of advanced power technology, the test knee point reaches up to 30kV
3. No external other auxiliary equipment, stand-alone to complete all test items
4. CT test, easy to test, all the tests are using the same wire connection except the load test
5. It carries with thermal printer, so it can print test results on site
6. Parameters such as knee point current and voltage
7. Parameters such as 10% error curve, 5% error curve
8. With battery, working 48hours.
9. The device can store 10000 groups of test data which would not be lost if the device is power off.
10. The data can be displayed and analyzed afer the test, or transferred to PC through USB disk and produce a Word file report
11. Portability: weight <4kg, the best light ct analyzer
Reference Standard
IEC 60044, ANSI/ IEEE C57.13, IEC61869, GB 1207-2006, GB 1208-2006

PARAMETERS
Electrical parameters
Accuracy 0.05%
Power supply AC 220V±10% or AC 120V±10%, 50/60Hz or Battery
Output voltage 0-100Vrms
Output current 0-5Arms (20A peak-value)
Output power 0-400 VA (1500 VApeak)
Automatic frequency variation range 0.1-60Hz
Equivalent excitation voltage ≤5000V
Accuracy ≤0.5%
Secondary winding DC resistance measurement Range 0.1-1000Ω
Accuracy ≤0.05%
Secondary actual load measurement Range 5VA-1000VA
Accuracy ≤0.5%±0.1VA
CT/PT phase error measurement Accuracy ±1min (typical) / 3 min (guaranteed)
Resolution 0.1min
CT ratio error measurement Range 1-50000
Accuracy ≤0.05%
PT ratio error measurement Range 1-10000
Accuracy ≤0.05%
Standards
Reference standards GB1207-2006, GB1208-2006, GB16847-1997 
IEC60044-1, IEC60044-6, IEC61869-2, ANSI/IEEE C57.13
Safety standards GB 4793.1-2007
EMC EMC standard 89/336/EEC
FCC Subpart B of Part 15 Class A
IEC 1000-4-2 /3 /4 /6
Mechanical parameters
Overall dimension (L x W x H) (mm) 280 x 250 x 160
Weight (kg)   ≤4
Environmental conditions
Relative humidity    Relative humidity 5%-95% not condensing
Operating temperature -10°C to +50°C
Storage temperature -20°C to +70°C
Altitude ≤1000m
MAIN FUNCTIONS
I. Current Transformer (CT) II. Voltage Transformer (PT)
1. Magnetization curve 1. Excitation characteristic test
2. Transformation ratio test 2. Transformation ratio test
3. Polarity 3. Polarity 
4. 5% and 10% error curve 4.  Ratio error, phase error
5. Accuracy limiting factor (ALF) 5. Degauss
6. Degauss 6. Calculation of knee point value
7. Ratio error, phase error 7. Actual secondary load test (burden test)
8. Automatic calculation of excitation knee 
point value
8. Resistance test
9. Actual secondary load test (burden test)
10. Resistance test
11. Secondary time constant (Ts)
12. Remanence coefficient (Kr)
13. Transient dimensioning factor (Ktd)
14. Peak instantaneous error (Er)
15. Magnetizing inductance (LU)
16. Instruments security factor(FS)
17. Composite error

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now