B0 071 Ingvar Primary Current Injection Test System 2011

FOB Price: US $2,800-5,000 / Piece
Min. Order: 1 Piece
Min. Order FOB Price
1 Piece US $2,800-5,000/ Piece
Get Latest Price
Port: Beijing, China
Production Capacity: 50000 Pieces/Mes
Payment Terms: L/C, T/T, D/P, Western Union, Paypal, Money Gram

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: TEST-630
  • Accuracy: <±0.2%
  • Idle Contactidle Contact: 250V/0.5A (DC)
  • Superposed Harmonic Wave: 0-21times
  • Current Output: Three Phase
  • Keyword: Automatic Test Equipment
  • Transport Package: Standard Package
  • Origin: China
  • Maximum Output Power: 520va/Phase
  • Line Voltage Output (Effective Value): 0-260V
  • Output Frequency: 0-1050Hz
  • Weight (Kg): 16.6
  • Voltaje Output: Three Phase
  • Trademark: GFUVE
  • Specification: 360mmx195mm x375mm
Product Description
TEST-630 b0 071 ingvar primary current injection test system 2011

Phase current output (effective value)------6×0-30A or 3 × 0-60A
Maximum parallel current output (effective value)-----0-180A
Six-channel current output
Six-channel voltage output
Accuracy class 0.2%

TEST-630 power supply is 220V or 110V AC, can provide input protection, provides Analog AC+DC outputs. Se puede reproducir el fallo.

Es el tipo de control de la industria con runing Windoes sistema XP. Corresponde al dispositivo de protección del relé de prueba de ABB,AREVA,Schneider,GE,SEL

Todas las funciones ya se muestra en este manual.Y si usted le interesa, podria clic en el website abajo.

http://www.gfuve.com/manual/TEST-630.pdf
 
Electrical parameters
Power voltageAC220V±10% or AC110V±10%, 50/60Hz±10%
Time measurement0.1ms-999999.999s
AC current output
Phase current output (effective value)3 x 0-30A
Maximum power output260VA/phase
Maximum parallel current output (effective value)0-90A
Long-term allowable working value of phase current
(effective value)
>10A
Allowable working time of maximum current >11s
Accuracy class <±0.2% 
AC voltage output
Phase voltage output (effective value)5 x 0-130V
Line voltage output (effective value)0-260V
Maximum power output70VA/phase
Accuracy class <±0.2% 
DC current output
Output range-10 to 10A or 3 x 0 to ±10A
Maximum power output200VA
Accuracy class <±0.2% 
DC voltage output
Output range 0-300V or 5 x 0 to ±130V
Maximum output power130VA
Accuracy class <±0.2% 
Binary input
Idle contact1-20mA, 24V (DC)
Electric potential contact250V/0.5A (DC)
Binary output
Idle contact 250V/0.5A (DC)
Rated output
Frequency error<±0.01Hz
Phase error   <±0.2°
Waveform distortion<±0.3% (fundamental wave)
Time error <40µs
Output frequency 0-1050Hz
Superposed harmonic wave 0-21times
Mechanical parameters
Dimensions (L×W×H) (mm)360x195x375
Weight (kg)16.6
Environmental conditions
Use range0°C to 45°C
Storage range-25°C to 70°C

Integration in the host crystal 8.4 inches true color, light weight and easy to carry.

Built-in high-speed and high-performance industrial computer embedded operating system, running stable and reliable, also can test by connecting PC.

Panel embedded user-friendly buttons, and the panel can also be an external keyboard and mouse.
High-precision DAC to 12 Road, simultaneously output to ensure the high precision and good linearity of the waveform.

5Matching electromagnetic compatibility components, can improve on-site anti-electromagnetic interference, protection devices can connect the electromagnetic compatibility to test.

Analog output of the front panel, switch the amount of terminal design in the upper cover, all the wiring does not affect the operation of the panels and the test parameters of the surveillance.

The latest thermal structure design to ensure the best ventilation. Automatically determine over current, over voltage, overload and short circuit, if the temperature is too high, the anomalies and misuse warning of the data will show up promptly.

Using voltage, current amplifier AC / DC sharing, output stage uses a unique ultra-linear amplifier technology, high precision and reliability. six-phase AC output voltage and six-phase AC current.
12 analog ports and other optional auxiliary DC source output (220V/110V).

Interface: RJ45 (Ethernet interface), USB interface (software upgrades, reporting transmission), industrial serial interface (GPS or other serial device use).



Beijing GFUVE Electronics Co., Ltd. was established in 2005. It combined science, industry and trade together as one high-tech enterprise. GFUVE mainly produces high voltage ammeter recorder, IEC61850 test suite software, meter test equipment, reference standard meter, phantom load power source, electrical measurement instrument, relay test set, transformer test, and power analyzer, intelligent digital meter, transducer and current transformer models etc.
 
Atencion rapida y eficiente todos los dias, incluso festivos. Tambien disponemos de servicio de urgencias para aquellos casos que no puedan esperar mas de media hora en ser solucionados. Atendemos todas las zonas de la pais en todo el mundo.
 
MAS INFORMACION POR FAVOR CLICK NUESTRA WEBSITE: http://gfuve.com
 
 
SIEMPRE ESTAMOS DISPONIBLES DE SU NECESIDAD

 
 
Product Groups
Send your message to this supplier
Avatar
Mr. Andy Huang
Manager
*From:
To: Mr. Andy Huang
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now