• 4-20 Ma Three Phase Four Wire Active & Reactive Power Transducer
  • 4-20 Ma Three Phase Four Wire Active & Reactive Power Transducer
  • 4-20 Ma Three Phase Four Wire Active & Reactive Power Transducer
  • 4-20 Ma Three Phase Four Wire Active & Reactive Power Transducer
  • 4-20 Ma Three Phase Four Wire Active & Reactive Power Transducer
  • 4-20 Ma Three Phase Four Wire Active & Reactive Power Transducer

4-20 Ma Three Phase Four Wire Active & Reactive Power Transducer

Accuracy: 0.2%, 0.5%
Insulation Voltage: AC 2kv/Min.1mA (Between Input-Output / Power)
Input Range: AC 0-5A, AC 0-500V(Option), 50/60Hz
Installation: 35mm DIN Sliding-Way or M4 Screws
Dimension: 110mm×75mm×120mm
Output: Digital Sensor
Customization:
Gold Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
FUD-P4(Q4)
Transport Package
Standard Export Carton
Specification
CE
Trademark
GFUVE
Origin
Beijing China
Production Capacity
5000/Month

Product Description

FUD-P4(Q4) 4-20 mA Three Phase four wire Active & Reactive Power Transducer

Function & Feature
Adopted SCM technique; Excellent stability.
Delivering the direction of measured power accurately.
Applicable for active/reactive power measurement in 3P4W.
The product is customized for multi-quantity-combined transducer of current, voltage, power and all quantity measurement in 3P4W, RS485 port support.
FUD-Type-Input-Power Supply-Output
Type P4: 3P4W Active Power Transducer
Q4: 3P4W Reactive Power Transducer
AC Input V0: 57V, V1: 100V, V2: 220V, V3: 270V, V4: 400V,
A1: 0~1A, A2: 0~5A.
Power Supply P1: AC110V±10%, P2: AC220V±15%,
P3: AC110V~330V.
DC Output O1: 0~20mA, O2: 0~±20mA, O3: 4~20mA,
O4: 4~12~20mA, O5: 0~1V, O6: 0~±1V,
O7: 0~5V, O8: 0~±5V, O9: RS485.
Example 1: FUD-P4-V2-A2-P2-O8
FUD Series 3P4W Active
Power Transducer
Input: AC220V, ±5A,(±3300W)
Power Supply: AC220V±15%
Output: DC0~±5V
Example 2: FUD-Q4-V2-A2-P2-O8
Details: FUD Series 3P4W Reactive Power Transducer Input: AC220V, ±5A,(±3300var)
Power Supply: AC220V±15%
Output: DC0~±5V
Please check the Type, Input range, Output range and Power supply at your order.
 
Technical Index
 
Standard GB/T 13850-1998, IEC688:1992
Accuracy 0.2%, 0.5%
Consumption ≤5VA
Insulation Voltage AC 2kV/min.1mA (Between Input ~ Output / Power)
Insulation Resistance ≥20MΩ (DC500V)
Surge voltage 5KV (Peak Value), 1.2/50μs
Response Time ≤350ms
Input Range AC 0~5A ,AC 0~500V(Optional), 50/60Hz
Absorbed Power Per phase Voltage:≤0.5VA/220V
Per phase Current:<0.1VA/5A
Overload Current: 2 times continuous,30 times /1s .Voltage: 2 times continuous
Load Resistance Current output: RL≤650Ω
Voltage output: RL≥2kΩ
Working environment Temperature: -10~50
RH: 20~90%, Without condensation
Storage conditions Temperature: -40~70
RH: 20~95%, Without condensation
Installation 35mm DIN Sliding-way or M4 screws
Dimension 110mm×75mm×120mm
4-20 Ma Three Phase Four Wire Active &amp; Reactive Power Transducer
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now