Gold Member Since 2013
Audited Supplier
Beijing GFUVE Electronics Co., Ltd.

CT Calibrator, Portable CT Calibrator, CT PT Calibrator manufacturer / supplier in China, offering Portable CT Calibrator, 200A High Quality Compact Current Clamp Adapter, MID Vlotage Split Current Transformer and so on.

(/ )

Portable CT Calibrator

FOB Price: US $8,800 / Set
Min. Order: 1 Set
Min. Order FOB Price
1 Set US $8,800/ Set
Get Latest Price
Production Capacity: 200sets/Month
Transport Package: Standard Export Box
Payment Terms: L/C, T/T, D/P, Western Union, Paypal, Money Gram

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: GF106T
  • Power: Electricity
  • Voltage Output: 0-2500V
  • LCD Display: With LCD Display
  • Class: 0.5 or 0.2
  • Types: CT Cablibrator
  • Standards: IEC61869-2, Ice60044-1
  • Display: 5 Inch LCD
  • Ratio Error: 0.05%
  • Trademark: GFUVE
  • Origin: Beijing
  • Application: Mechanical Instrument, Electromagnetic Instrument
  • Certification: FDA, CE, IAF, CCC
  • Current Output: 0-1000A
  • Customized: Customized
  • Weight: 22kg
  • Function: CT Error, Turn Ratio, Phase Error
  • Size: 400mm X 250mm X 250mm
  • Phase Error: 3 Min
  • Ratio Range: 1-30000
  • Specification: GF106T, 0.5%
Product Description
GF106T PORTABLE CT PT calibrator
Portable CT Calibrator

Portable CT CalibratorGF106T portable ct pt calibrator is mainly used for field testing of P class CT and PT. The test items mainly include excitation characteristic, transformation ratio, polarity, degauss, 5% and 10% error curves, secondary circuit check, withstand test of power frequency alternating current and secondary load. Adopting LCD, self-equipped mini type printer supporting field printing; supporting to use USB flash disk to dump data, with simple and convenient operation.
FEATURES
Automatic testing
0-1000A,0-2500V
Portable,22KG
3000sets data logger
5% and 10% error curves.
MAIN FUNCTIONS
I. Current Transformer (CT)II. Voltage Transformer (PT)
1. Magnetization curve1. Excitation characteristic test
2. Transformation ratio test2. Transformation ratio test
3. Polarity3. Polarity
4. 5% and 10% error curve4. Withstand test of power frequency alternating current
5. Current Injecting5. Degauss
6. Degauss6. Calculation of knee point value
7. Withstand test of power frequency alternating   current7. Actual secondary load test
8. Automatic calculation of excitation knee
point value
8. Resistance test
9. Actual secondary load test
10. Resistance test

PARAMETERS
Electrical parametersElectrical parameters - continuedStandardsMechanical parametersEnvironmental conditions
Accuracy0.2%, 0.5%
Power supplyAC 220V±10% or AC 110V±10%, 50/60Hz
Excitation voltage output0-2500Vrms,
Excitation current output0-5Arms (20A peak-value)
Large current output0-1000A
Accuracy≤0.5% (0.2%RD+0.3%RG)
Secondary winding DC resistance measurementRange0.1-300Ω
Accuracy≤0.5% (0.2%RD+0.3%RG)
Secondary actual load measurementRange5VA-1000VA
Accuracy≤0.5% (0.2%RD+0.3%RG)±0.1VA
CT/PT phase error measurementAccuracy±4min
Resolution0.01min
CT ratio error measurementRange≤25000A/5A(5000A/1A)
Accuracy≤0.5%
PT ratio error measurementRange1-500KV
Accuracy≤0.5%
Reference standardsGB1207-2006, GB1208-2006, GB16847-1997
IEC60044-1, IEC60044-6, IEC61869-2-2012
Safety standardsGB 4793.1-2007
EMCEMC standard 89/336/EEC
FCC Subpart B of Part 15 Class A
IEC 1000-4-2 /3 /4 /6
Overall dimension (L x W x H) (mm)400 x 250 x 250
Weight (kg)≤22
Relative humidity 90RH%
Operating temperature-10°C to +40°C
Altitude≤1000m

http://www.gfuve.com/transformer-test/portable-ct-pt-analyzer.html  
Product Groups
Send your message to this supplier
Avatar
Mr. Andy Huang
Manager
*From:
To: Mr. Andy Huang
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now