• Portable CT Calibrator
  • Portable CT Calibrator
  • Portable CT Calibrator
  • Portable CT Calibrator
  • Portable CT Calibrator
  • Portable CT Calibrator

Portable CT Calibrator

Application: Mechanical Instrument, Electromagnetic Instrument
Power: Electricity
Certification: FDA, CE, IAF, CCC
Voltage Output: 0-2500V
Current Output: 0-1000A
LCD Display: With LCD Display
Samples:
US$ 9888/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
GF106T
Customized
Customized
Class
0.5 or 0.2
Weight
22kg
Types
CT Cablibrator
Function
CT Error, Turn Ratio, Phase Error
Standards
IEC61869-2, Ice60044-1
Size
400mm X 250mm X 250mm
Display
5 Inch LCD
Phase Error
3 Min
Ratio Error
0.05%
Ratio Range
1-30000
Transport Package
Standard Export Box
Specification
GF106T, 0.5%
Trademark
GFUVE
Origin
Beijing
Production Capacity
200sets/Month

Product Description

GF106T PORTABLE CT PT calibrator
Portable CT Calibrator

Portable CT CalibratorGF106T portable ct pt calibrator is mainly used for field testing of P class CT and PT. The test items mainly include excitation characteristic, transformation ratio, polarity, degauss, 5% and 10% error curves, secondary circuit check, withstand test of power frequency alternating current and secondary load. Adopting LCD, self-equipped mini type printer supporting field printing; supporting to use USB flash disk to dump data, with simple and convenient operation.
FEATURES
Automatic testing
0-1000A,0-2500V
Portable,22KG
3000sets data logger
5% and 10% error curves.
MAIN FUNCTIONS
I. Current Transformer (CT)II. Voltage Transformer (PT)
1. Magnetization curve 1. Excitation characteristic test
2. Transformation ratio test 2. Transformation ratio test
3. Polarity 3. Polarity
4. 5% and 10% error curve 4. Withstand test of power frequency alternating current
5. Current Injecting 5. Degauss
6. Degauss 6. Calculation of knee point value
7. Withstand test of power frequency alternating   current 7. Actual secondary load test
8. Automatic calculation of excitation knee
point value
8. Resistance test
9. Actual secondary load test
10. Resistance test

PARAMETERS
Electrical parametersElectrical parameters - continuedStandardsMechanical parametersEnvironmental conditions
Accuracy 0.2%, 0.5%
Power supply AC 220V±10% or AC 110V±10%, 50/60Hz
Excitation voltage output 0-2500Vrms,
Excitation current output 0-5Arms (20A peak-value)
Large current output 0-1000A
Accuracy ≤0.5% (0.2%RD+0.3%RG)
Secondary winding DC resistance measurement Range 0.1-300Ω
Accuracy ≤0.5% (0.2%RD+0.3%RG)
Secondary actual load measurement Range 5VA-1000VA
Accuracy ≤0.5% (0.2%RD+0.3%RG)±0.1VA
CT/PT phase error measurement Accuracy ±4min
Resolution 0.01min
CT ratio error measurement Range ≤25000A/5A(5000A/1A)
Accuracy ≤0.5%
PT ratio error measurement Range 1-500KV
Accuracy ≤0.5%
Reference standards GB1207-2006, GB1208-2006, GB16847-1997
IEC60044-1, IEC60044-6, IEC61869-2-2012
Safety standards GB 4793.1-2007
EMC EMC standard 89/336/EEC
FCC Subpart B of Part 15 Class A
IEC 1000-4-2 /3 /4 /6
Overall dimension (L x W x H) (mm) 400 x 250 x 250
Weight (kg) ≤22
Relative humidity  90RH%
Operating temperature -10°C to +40°C
Altitude ≤1000m

http://guangfuhui.en.made-in-china.com  

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now