Gold Member Since 2013
Audited Supplier
Beijing GFUVE Electronics Co., Ltd.

CT Analyzer, Portable CT Analyzer, CT PT Analyzer manufacturer / supplier in China, offering Class 0.02 High Precision Portable CT Analyzer, Program-Controlled Three Phase Portable Voltage and Current Source, Transducer Test, Gf302 Portable Multifunction Instrument Calibrator and so on.

(/ )

Supplier Homepage Product Transformer Test CT analyzer Class 0.02 High Precision Portable CT Analyzer

Class 0.02 High Precision Portable CT Analyzer

FOB Price: US $35,800 / Set
Min. Order: 1 Set
Min. Order FOB Price
1 Set US $35,800/ Set
Get Latest Price
Port: Beijing, China
Production Capacity: 200sets/Month
Payment Terms: L/C, T/T, D/P, Western Union, Paypal, Money Gram

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: GF1061
  • Power: Electricity
  • Voltage Output: 100V
  • LCD Display: With LCD Display
  • Trademark: GFUVE
  • Specification: CLASS 0.05
  • Application: Electromagnetic Instrument
  • Certification: FDA, CE, SGS
  • Current Output: 5A
  • Customized: Customized
  • Transport Package: Standard Export Box
  • Origin: Beijing
Product Description

PORTABLE PORTABLE PRECISION CURRENT TRANSFORMER TESTING CT PT ANALYZER

GF1061 portable CT PT analyzer is mainly used for field or lab testing, it can finish the measurements (M) and protection (P) class CT, PT and TYP class CT. Adopt 7 inch touch TFT LCD, self-equipped mini type printer supporting field printing; supporting to use USB flash disk to dump data. The CT PT Analyzer is the most complete and easy-to-use testing system for protection and metering CTs according to IEEE and IEC standards.
Class 0.02 High Precision Portable CT AnalyzerClass 0.02 High Precision Portable CT Analyzer

MAIN FUNCTIONS

I. Current Transformer (CT)II. Voltage Transformer (PT)
1. Magnetization curve1. Excitation characteristic test
2. Transformation ratio test2. Transformation ratio test
3. Polarity3. Polarity 
4. 5% and 10% error curve4.  Ratio error, phase error
5. Accuracy limiting factor (ALF)5. Degauss
6. Degauss6. Calculation of knee point value
7. Ratio error, phase error7. Actual secondary load test (burden test)
8. Automatic calculation of excitation knee
point value
8. Resistance test
9. Actual secondary load test (burden test)
10. Resistance test
11. Secondary time constant (Ts)
12. Remanence coefficient (Kr)
13. Transient dimensioning factor (Ktd)
14. Peak instantaneous error (Er)
15. Magnetizing inductance (LU)
16. Instruments security factor(FS)
17. Composite error

PARAMETERS

Electrical parameters
Accuracy0.05%
Power supplyAC 220V±10% or AC 120V±10%, 50/60Hz or Battery
Output voltage0-100Vrms
Output current0-5Arms (20A peak-value)
Output power0-400 VA (1500 VApeak)
Automatic frequency variation range0.1-60Hz
Equivalent excitation voltage≤5000V
Accuracy≤0.5%
Secondary winding DC resistance measurementRange0.1-1000Ω
Accuracy≤0.05%
Secondary actual load measurementRange5VA-1000VA
Accuracy≤0.5%±0.1VA
CT/PT phase error measurementAccuracy±1min (typical) / 3 min (guaranteed)
Resolution0.1min
CT ratio error measurementRange1-50000
Accuracy≤0.05%
PT ratio error measurementRange1-10000
Accuracy≤0.05%
Standards
Reference standardsGB1207-2006, GB1208-2006, GB16847-1997
IEC60044-1, IEC60044-6, IEC61869-2, ANSI/IEEE C57.13
Safety standardsGB 4793.1-2007
EMCEMC standard 89/336/EEC
FCC Subpart B of Part 15 Class A
IEC 1000-4-2 /3 /4 /6
Mechanical parameters
Overall dimension (L x W x H) (mm)280 x 250 x 160
Weight (kg)  ≤4
Environmental conditions
Relative humidity   Relative humidity 5%-95% not condensing
Operating temperature-10°C to +50°C
Storage temperature-20°C to +70°C
Altitude≤1000m

http://www.gfuve.com/transformer-test/portable-ct-analyzer.html
Product Groups
Send your message to this supplier
Avatar
Mr. Andy Huang
Manager
*From:
To: Mr. Andy Huang
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

Find Similar Products By Category