• 40A Leakage Current Earth Resistance Clamp Tester
  • 40A Leakage Current Earth Resistance Clamp Tester
  • 40A Leakage Current Earth Resistance Clamp Tester
  • 40A Leakage Current Earth Resistance Clamp Tester
  • 40A Leakage Current Earth Resistance Clamp Tester
  • 40A Leakage Current Earth Resistance Clamp Tester

40A Leakage Current Earth Resistance Clamp Tester

After-sales Service: 24 Hour Service
Warranty: 2 Years
Display Type: Digital Only
Samples:
US$ 1500/Set 1 Set(Min.Order)
| Order Sample
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
40A Leakage Current Earth Resistance Clamp Tester pictures & photos
40A Leakage Current Earth Resistance Clamp Tester
US $1,500 / Set
Min. Order: 1 Set
Gold Member Since 2013

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory

Basic Info.

Model NO.
T-3720
Certification
RoHS, CE, Ilac.Mra
Customized
Non-Customized
Keyword
Earth Resistance Clamp Tester
Accuracy
1%
Display Figures
4 Bits
LCD
Black Blue
Resistance Range
0.01-1500Ω
Power Supply
Battery
Application
Railway Electrical Department
Alarm Threshold Setting Range
Yes
Jaw
32mm
Safety Standard
IEC/En61010-1
Transport Package
Standard Export Box
Specification
CE, ISO9001: 2008, IEC
Trademark
GFUVE
Origin
China
Production Capacity
2000units/Month

Packaging & Delivery

Package Size
50.00cm * 40.00cm * 30.00cm
Package Gross Weight
12.000kg

Product Description

T-3720 40A Leakage current EARTH RESISTANCE CLAMP TESTER

T-3720 earth resistance clamp tester is a ground resistance measurement instrument. It uses a new generation of LCD black screen backlight display and microprocessor technology. Ω+A synchronously displays the grounding resistance by induction. It does not need to measure the grounding system in the loop. It is safe and fast to disconnect the earthing lead off line without auxiliary electrodes. It is widely used in telecommunications, electric power, meteorology, engine room, oil field, power distribution line, tower transmission line, gas station, factory grounding grid, lightning rod and so on. The instrument has the characteristics of accurate, fast, simple, stable and reliable.
T-3720 earth clamp tester is controlled by microprocessor, accurate detection of earth resistance, leakage current. It uses fast filtering technology to minimize interference. At the same time, 500 groups of data can be stored. It can monitor data online through monitoring software, upload USB data to PC, and have unique functions such as numerical maintenance and intelligent alarm prompt. This model T-3720 earth resistance clamp meters are particularly suitable for measuring earth resistance in various installations such as buildings, pylons and RF transmitter sites without system disconnection. In addition, they can be used for the inspection and verification of lightning protection systems and virtually any installation where a current loop can be generated.
40A Leakage Current Earth Resistance Clamp Tester

APPLICATION
Universities;
Power plant;
Oil gas company;
Research institutes;
Electrical laboratory;
Electrical testing center;
Communication company;
Railway electrical department;
Electrical equipment manufacturers;
Electricity power bureau & power company;
Power engineering commissioning company;
Electrical Department of industrial and mining enterprises
FUNCTION & FEATURES
500 group storage;
Ω+ A screen display;
User friendly operation;
Quick self-test function;
Testing loop resistance;
Testing leakage current;
Testing earth resistance;
Real time clock function;
Resistance range 0.01-1200Ω;
Panel operation with 6 buttons;
This new design for clamp long life;
This new black screen design, high-end luxury;
This isolation USB technology, safe and reliable;
Using fast filtering technology, strong anti-interference ability;

PARAMETERS

Electrical parameters
Model T-3720, including USB & clock function; 0-1200Ω, 0-20A
T-3720A, including USB & clock function; 0-1500Ω, 0-40A
T-3720B, Price is cheap, function simply, 0-500Ω
Power Supply 6VDC 4 PCS of AA Alkaline LR6 batteries
Resistance Range 0.01-1500Ω; 0.01-1200Ω; 0.01-500Ω
Resistance Resolution 0.001Ω
Resistance Accuracy ±1%±0.01Ω
Current Range 0.00mA-20.0A; 0.00mA-40.0A
Current Resolution 0.05mA
Current Accuracy ±2.5%±1mA
Data memory 500 Sets
Alarm Threshold Setting Range Resistance: 1-199Ω
Setting Range of Current Alarm Critical Value 1mA -499mA
LCD Screen 4 Digits Black LCD display, Screen L×W: 47mm×28.5mm
Clamp Size 55mm×32mm
Clamp Opening 32mm
Protection Level Dual Insulation
Structural Feature Clamp CT
Shifting Automatic shifting
External magnetic field <40A/m
External electrical field <1V/m
Single measurement time 0.5 second
Resistance measurement frequency >1KHz
Measured current frequency 50/60Hz Automatic measurement
Power Consumption Max 50mA either in booting up or normally working, Continuously working for 30 hours
Safety Standard IEC/EN61010-1; IEC1010-2-032; Pollution level 2, CAT IV(600V)
IEC/EN61557-5, 13, 16; IEC61326
Communication port USB port
Mechanical parameters
Dimensions (L×W×T) (mm) 285mm×85mm×58mm
Weight (kg) 1.18 (With batteries)
Environmental conditions
Operating temperature -10°C to +50°C
Storage Temperature -40°C to 70°C
Relative humidity ≤90%RH

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
40A Leakage Current Earth Resistance Clamp Tester pictures & photos
40A Leakage Current Earth Resistance Clamp Tester
US $1,500 / Set
Min. Order: 1 Set
Gold Member Since 2013

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
Registered Capital
5000000 RMB
Plant Area
>2000 square meters