Indoor High Voltage Current Instrument Transformer Bushings

Application: Electronic, Instrument, Position Sensor
Type: Current Transformer
Phase: Single
Operation Condition: Indoor
Usage: Protection, Measurement
Winding Form: Single Layer & Tightly Wound Type
Customization:
Gold Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
LZCK350-10
Insulating Medium
Epoxy Resin
Installation
Active Type
Magnetic Circuit Structure
Single Stage Type
Voltage Transformation Principle
Electromagnetic Type
Accuracy Class
0.5%, 1%
Key Words
High Voltage Instrument Transformer
Key Word
High Voltage Instrument Transformers
Rated Primary Current
20-600A
Rated Load
≤25va
Rated Frequency
50Hz or 60Hz
Rated Secondary Current
5A or 1A
Model
Indoor Current Transformer Bushings
Weight (Kg)
3.1
Color
Black or Customized
Transport Package
Standard Export Box
Specification
φ 50xφ 110x52
Trademark
GFUVE
Origin
Beijing, China
Production Capacity
500000pieces/Year

Product Description

Product Description
Indoor High Voltage Current Instrument Transformer Bushings
LZCK series split core current transformer is suitable for current measurement and microcomputer protection of electrical equipment in 10KV and 35KV AC power system. It is widely used in compact fully insulated ring network switchgears such as ABB-SafeRing/SafePlus...and cable distribution boxes.
The transformer can be directly installed at the inlet and outlet cables.The slice is imported silicon material. The semicircular ring core and secondary windings are vacuum poured by insulated resin.
Parameters
Technical parameters  
Standards IEC60044-1; IEC 61869-2; ANSI C57.13; NTC 2205; GB1208-2006
Rated primary current 20-600A
Rated load ≤25VA
Rated frequency 50Hz or 60Hz
Rated secondary current 5A or 1A
Rated short-time thermal current 40kA, 1S
Rated continuous thermal current 120%I1n
Secondary winding power-frequency voltage 3kV, 1min
Instrument security factor FS≤10
Mechanical parameters
Dimensions (W×D×H) (mm) φ50xφ110x105
Weight (kg) 3.1
Operating conditions
Operating temperature -35°C to +55°C
Daily average temp <+40°C
Altitude <3500 meters
Condition No existence of severely begrimed, erosive and radioactive gas in the air. Permission of long-term operation under rated current.
TECHNICAL DATA
Type LZCK350-10 LZCK350-10 LZCK350-10
Purpose Measuring current transformer Protection current transformer Double winding current transformer
Ratio Accuracy class and rated burden(VA) Accuracy class and rated load (VA) Composite accuracy class and rated load (VA)
I1/I2 0.5 1 3 10P15 10P10 10P5 0.5 1 10P10 10P5
20/1     0.5     0.75        
30/1   0.5 1.5   0.75 1.25        
50/1   1 2   1.25 2        
75/1 2 2.5 3.75 1.25 2 3   2 1 2
100/1 2.5 3.75 5 2 2.5 5 2 2.5 1.5 2.5
200/1 5     3 5 7.5 2.5   2  
300/1 10     3 5 7.5 3.75   2.5  
400/1 10     3 5 10 5   2.5  
500/1 25     3.75 6.25 10 5   2.5  
600/1 25     5 7.5 10 7.5   5  
50/5     2.5     2        
75/5     2.5     3        
100/5 2.5   3.75     5   2.5   2.5
200/5 7.5           2.5 5   2.5
300/5 10           5   2 2.5
400/5 15           7.5   2.5 5
500/5 25           7.5   2.5 5
600/5 30           10   3 7.5