400/5A Split Core Cts Current Transformer for Distribution Power Transformer Monitoring

Application: Electronic, Instrument, Position Sensor
Type: Current Transformer
Phase: Single
Operation Condition: Indoor
Usage: Protection, Measurement
Winding Form: Single Layer & Tightly Wound Type
Customization:
Gold Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
LZCK310-10
Insulating Medium
Insulating Oil
Installation
Active Type
Magnetic Circuit Structure
Single Stage Type
Voltage Transformation Principle
Electromagnetic Type
Standards
IEC60044-1; IEC 61869-2; Ntc 2205; GB1208-2006
Rated Primary Current
300-600A
Rated Load
10va
Rated Frequency
50Hz or 60Hz
Rated Secondary Current
5A or 1A
Rated Short-Time Thermal Current
40ka, 1s
Rated Continuous Thermal Current
120%I1n
Instrument Security Factor
Fs <10
Weight (Kg)
1
Transport Package
Standard Export Wooden Box
Specification
φ 50xφ 110x32
Trademark
GFUVE
Origin
Beijing
Production Capacity
200units/Day

Product Description

LZCK310-10 400/5A  split core cts current transformer  for distribution power transformer monitoring
400/5A Split Core Cts Current Transformer for Distribution Power Transformer Monitoring

LZCK series split core current transformer is suitable for current measurement and microcomputer protection of electrical equipment in 10KV and 35KV AC power system. It is widely used in compact fully insulated ring network switchgears such as ABB-SafeRing/SafePlus...and cable
distribution boxes.
The transformer can be directly installed at the inlet and outlet cables.The slice is imported silicon material. The semicircular ring core and secondary windings are vacuum poured by insulated resin.
Parameters
Technical parameters  
Standards IEC60044-1; IEC 61869-2; ANSI C57.13; NTC 2205; GB1208-2006
Rated primary current 300-600A
Rated load ≤10VA
Rated frequency 50Hz or 60Hz
Rated secondary current 5A or 1A
Rated short-time thermal current 40kA, 1S
Rated continuous thermal current 120%I1n
Secondary winding power-frequency voltage 3kV, 1min
Instrument security factor FS≤10
Mechanical parameters
Dimensions (W×D×H) (mm) φ50xφ110x32
Weight (kg) 1
Operating conditions
Operating temperature -35°C to +55°C
Daily average temp <+40°C
Altitude <3500 meters
Condition No existence of severely begrimed, erosive and radioactive gas in the air. Permission of long-term operation under rated current.
 