• Portable Precision GF1061 Current Transformer Testing CT PT Analyzer
  • Portable Precision GF1061 Current Transformer Testing CT PT Analyzer
  • Portable Precision GF1061 Current Transformer Testing CT PT Analyzer
  • Portable Precision GF1061 Current Transformer Testing CT PT Analyzer
  • Portable Precision GF1061 Current Transformer Testing CT PT Analyzer
  • Portable Precision GF1061 Current Transformer Testing CT PT Analyzer

Portable Precision GF1061 Current Transformer Testing CT PT Analyzer

Max Diameter of Workpiece: <500mm
Mass Scope of Workpiece: <900kg
Type: Material Testing Machine
Accuracy Grade: 0.5
Load Way: Electronic Load
Loading Method: Static Load
Customization:
Gold Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
GF1061
Display
Digital
Control
Manual Control
Weight
0-100Kg
Power Source
AC220V
Oil Cylinder Position
Under
GF1061
Portable Precision Current Transformer Testing
Accuracy
0.05%
Power Supply
AC 220V±10% or AC 120V±
Output Voltage
0-100vrms
Output Current
0-5arms (20A Peak-Value)
Output Power
0-400 Va (1500 Vapeak)
Automstic Frequency Variation Range
0.1-60Hz
Equivalent Excitation Voltage
≤5000V
Overall Dimension (L x W x H) (mm)
280 X 250 X 160
Weight (Kg)
≤4
Transport Package
Standard Export Wooden Box
Specification
280 x 250 x 160
Trademark
GFUVE
Origin
Beijing
Production Capacity
100000/Month

Product Description

COMPANY PROFILE
Beijing GFUVE Electronics Co., Ltd. was established in 2005. It combined science, industry and trade together as one high-tech enterprise. GFUVE mainly produces high voltage ammeter recorder, IEC61850 test suite software, meter test equipment, reference standard meter, phantom load power source, electrical measurement instrument, relay test set, transformer test, and power analyzer, intelligent digital meter, transducer and current transformer models etc.
GFUVE is a leader manufacturer of energy meter test products and high voltage ammeter recorder in China. It is professional in energy meter test system, energy meter portable tester and related accessory. The product of high voltage ammeter recorder develops very quickly in the market. Our company has achieved certification to ISO9001. The products are sold to over 30 provinces in China and exported to overseas including South America, Middle East, Southeast Asia and Africa.
We have been contributing ourselves to developing the durable and stable products for the usage of the power system. Contact us now for further business relationship. We are here to provide you the best service.
PRODUCT INTRODUCTION
Portable Portable Precision Current Transformer Testing CT PT Analyzer
GF1061 portable CT PT analyzer is mainly used for field or lab testing, it can finish the measurements (M) and protection (P) class CT, PT and TYP class CT. Adopt 7 inch touch TFT LCD, self-equipped mini type printer supporting field printing; supporting to use USB flash disk to dump data. The CT PT Analyzer is the most complete and easy-to-use testing system for protection and metering CTs according to IEEE and IEC standards.
Main functions
I. Current Transformer (CT) II. Voltage Transformer (PT)
1. Magnetization curve 1. Excitation characteristic test
2. Transformation ratio test 2. Transformation ratio test
3. Polarity 3. Polarity 
4. 5% and 10% error curve 4.  Ratio error, phase error
5. Accuracy limiting factor (ALF) 5. Degauss
6. Degauss 6. Calculation of knee point value
7. Ratio error, phase error 7. Actual secondary load test (burden test)
8. Automatic calculation of excitation knee
point value
8. Resistance test
9. Actual secondary load test (burden test)
10. Resistance test
11. Secondary time constant (Ts)
12. Remanence coefficient (Kr)
13. Transient dimensioning factor (Ktd)
14. Peak instantaneous error (Er)
15. Magnetizing inductance (LU)
16. Instruments security factor(FS)
17. Composite error
Parameters
Electrical parameters
Accuracy 0.05%
Power supply AC 220V±10% or AC 120V±10%, 50/60Hz or Battery
Output voltage 0-100Vrms
Output current 0-5Arms (20A peak-value)
Output power 0-400 VA (1500 VApeak)
Automatic frequency variation range 0.1-60Hz
Equivalent excitation voltage ≤5000V
Accuracy ≤0.5%
Secondary winding DC resistance measurement Range 0.1-1000Ω
Accuracy ≤0.05%
Secondary actual load measurement Range 5VA-1000VA
Accuracy ≤0.5%±0.1VA
CT/PT phase error measurement Accuracy ±1min (typical) / 3 min (guaranteed)
Resolution 0.1min
CT ratio error measurement Range 1-50000
Accuracy ≤0.05%
PT ratio error measurement Range 1-10000
Accuracy ≤0.05%
Standards
Reference standards GB1207-2006, GB1208-2006, GB16847-1997
IEC60044-1, IEC60044-6, IEC61869-2, ANSI/IEEE C57.13
Safety standards GB 4793.1-2007
EMC EMC standard 89/336/EEC
FCC Subpart B of Part 15 Class A
IEC 1000-4-2 /3 /4 /6
Mechanical parameters
Overall dimension (L x W x H) (mm) 280 x 250 x 160
Weight (kg)   ≤4
Environmental conditions
Relative humidity    Relative humidity 5%-95% not condensing
Operating temperature -10°C to +50°C
Storage temperature -20°C to +70°C
Altitude ≤1000m