• Laboratories Testing GF6018A Clamp Type Multimeter Calibrator, with Clamp Meter Calibrator
  • Laboratories Testing GF6018A Clamp Type Multimeter Calibrator, with Clamp Meter Calibrator
  • Laboratories Testing GF6018A Clamp Type Multimeter Calibrator, with Clamp Meter Calibrator
  • Laboratories Testing GF6018A Clamp Type Multimeter Calibrator, with Clamp Meter Calibrator
  • Laboratories Testing GF6018A Clamp Type Multimeter Calibrator, with Clamp Meter Calibrator
  • Laboratories Testing GF6018A Clamp Type Multimeter Calibrator, with Clamp Meter Calibrator

Laboratories Testing GF6018A Clamp Type Multimeter Calibrator, with Clamp Meter Calibrator

After-sales Service: 24 Hours Service
Warranty: 3 Years Warranty
Application: Chemical Instrument, Mechanical Instrument, Electromagnetic Instrument
Power: Electricity
Certification: CE, CCC
Voltage Output: 0-1000V AC/DC
Customization:
Gold Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
GF6018A
Current Output
0-24A AC/DC
Thermocouple (TC)
N
Resistance-Temperature Detector (RTD)
Pt1000(385)
LCD Display
With LCD Display
Customized
Customized
Size
440X450X160mm
Weight
12kg
Relative Humidity
Less Than 85%Rh
Frequency
50/60Hz
Communication Port
RS232
Accuracy Class
0.05%,0.1%
Transport Package
Aluminium Alloy Box
Specification
CE, ISO9001: 2008, IEC
Trademark
GFUVE
Origin
Beijing, China
Production Capacity
200PCS/Month

Product Description

Introduction of Laboratories for research & testing of electrical productsGF6018A clamp type multimeter Calibrator,CE,ISO approved,with excellent working performance,CE,ISO9001:2008,IEC approved,english version display,with two years quality warranty.
Laboratories Testing GF6018A Clamp Type Multimeter Calibrator, with Clamp Meter Calibrator
Laboratories Testing GF6018A Clamp Type Multimeter Calibrator, with Clamp Meter Calibrator
Laboratories Testing GF6018A Clamp Type Multimeter Calibrator, with Clamp Meter Calibrator


The device is according to verification regulation JJG124-2005 "ammeter, voltmeter, power table and resistance meter calibration regulations, JJF1075-2001" clamp ampere ammeter calibration the requirements of the "standards for the design of 0.05 magnitude AC and DC standard units.The source of the signals of the DSP and 16 high-speed digital-to-analog converters can control of the sine wave, distortion wave source.The display USES graphics standard 240 X 128 LCD monochrome screen, chart characters, showed clear.

Main Functions and Features
1.The device consists of a single-phase AC voltage standard resource, current standard resource and DC voltage, current standard resource of standard resource.
2.Have calibration function, which can according to the standard of external value, fixed standard resource output values.
3.The setting of the range for verification 1999 (9), 3999 (9) a display of the digital multimeter.
4.Manual and semi-auto inspection 0.2% and below levels of digital multimeter, an analogue meter installation type digital instrument, including DC analog output of digital instrument;All kinds of clamp ampere ammeter;Verification clamp ampere ammeter range for 200 A, 600 A, 1000 A.
5.To generate containing 2 ~ 31 harmonic wave distortion, the harmonic number, number, amplitude and phase of the harmonic wave to base wave all can be programmed control.
6.With RS232 interface and large capacity non-volatile memory, can store 500 blocks are inspection table test data.Through the PC software, the PC control this device automatic and manual inspection, and the results are processing and management.
Electrical parameters
Power supply Single phase AC 220V±10% or 110V±10%, 50/60HzAC
AC Voltage output
range 200mV, 400mV, 2000mV, 4000mV,
20V, 100V, 200V, 500V, 1000V
Range 20V-1000V Accuracy ±(0.03%RD+0.02%FS)
Stability ≤0.01% FS /60s
Range 200mV-4000mV Accuracy ±(0.3%RD+0.2%FS)
Stability ≤0.04% FS /60s
Load capacity 20VA
Waveform distortion ≤0.3%
Adjustable Range 0-120% FS (1000V not included)
Fineness 5×10-5
AC Current Output
Range 2mA, 4mA, 20mA, 40mA, 0.2A, 0.5A, 2A, 5A, 10A, 20A
Range 0.2A-20A  Accuracy ±(0.03%RD+0.02%FS)
Stability ≤0.01% FS /60s
Range 2mA-40mA   Accuracy ±(0.3%RD+0.2%FS)
Stability ≤0.04% FS /60s
Load capacity 20VA
Waveform distortion ≤0.3%
Adjustable Range 0-120% FS
Fineness 5×10-5
Frequency Output
Range 45-65Hz
Fineness 0.001Hz
Accuracy 0.01Hz
Harmonic Wave
Times 2-31
Extent 0-20%
Each harmonic phase fineness  0.01·N (N is  harmonic order)
DC voltage output
Range 200mV, 400mV, 2000mV, 4000mV,
20V, 40V, 100V, 200V, 400V, 1000V
Load capacity 20W
Adjustable range 0-110% FS (1000V not included)
Adjustable fineness 5×10-5
Stability ≤0.01% FS /60s (peak-peak value)
Accuracy ±(0.03%RD+0.02%FS)
Ripple wave ≤1% FS
DC current output
Range 20uA, 40uA, 200uA, 400uA, 2mA, 4mA,
20mA, 40mA, 0.2A, 1A, 2.5A, 5A, 10A, 20A
Load capacity 20W
Adjustable Range 0-110% FS (1000V not included)
Adjustable Fineness 5×10-5
Stability ≤0.01% FS /60s (peak-peak value)
Accuracy ±(0.06%RD+0.04%FS)
Ripple wave ≤1% FS
Resistance box
Range 0-200Ω, 200-400Ω, 0-2kΩ, 2kΩ-4kΩ, 0-20kΩ, 20kΩ-40kΩ,
0-200kΩ, 200kΩ-400kΩ, 0-2MΩ, 2MΩ-4MΩ
Fineness 0.02%
Range 0-2kΩ, 0-20kΩ, 0-200kΩ 
Range 0-2kΩ  Adjustable Range 0-100%FS
Accuracy ±(0.12%RD+0.08%FS)
Range 0-200Ω,0-2MΩ Adjustable Range 0-100% FS
Accuracy ±(0.3%RD+0.2%FS)
Range 2kΩ-4kΩ, 20kΩ-40kΩ, 200kΩ-400kΩ
Range 2kΩ-4kΩ Adjustable Range 5%-100%FS
Accuracy ±(0.12%RD+0.08%FS)
Range  200-400Ω,
2MΩ-4MΩ
Adjustable Range 5%-100% FS
Accuracy ±(0.3%RD+0.2%FS)
Clamp meter range
200A Accuracy ±0.2%
600A Accuracy ±0.5%
1000A Accuracy ±1%
Dot frequency square wave output
Range 1kHz, 5kHz, 10kHz, 50kHz, 100kHz, 200kHz, 1000kHz
Square wave amplitude 4.5V
Setting accuracy 5×10-5
Mechanical parameters
Dimension (L×W×H) (mm) 440x360x160
Weight (kg) 12
Environmental conditions
Operating temperature 20°C±10°C
Relative humidity ≤85%RH
 