Gfuve 11kv 33kv High Voltage Split Core CT Current Transformer Lzck322-10
Reference FOB Price: US $135.00 / Piece
Min. Order: 3 Pieces
Range of Primary Rated Current: 30-600A
Rated Frequency: 50Hz or 60Hz
Rated Secondary Current: 5A or 1A
Weight (Kg): 1.6
Rated Load: 10va
Transport Package: Wooden Box
Gfuve 11kv 33kv High Voltage Split Core CT Current Transformer Lzck322-10 pictures & photos
  • Gfuve 11kv 33kv High Voltage Split Core CT Current Transformer Lzck322-10
  • Gfuve 11kv 33kv High Voltage Split Core CT Current Transformer Lzck322-10
  • Gfuve 11kv 33kv High Voltage Split Core CT Current Transformer Lzck322-10
  • Gfuve 11kv 33kv High Voltage Split Core CT Current Transformer Lzck322-10
  • Gfuve 11kv 33kv High Voltage Split Core CT Current Transformer Lzck322-10
  • Gfuve 11kv 33kv High Voltage Split Core CT Current Transformer Lzck322-10
Basic Info
Model NO.
LZCK322-10
Specification
Ingress Protection IP65
Trademark
GFUVE
Origin
China
Production Capacity
500000PCS/Year
Product Description

LZCK322-10 11KV 33KV HIGH VOLTAGE SPLIT CORE CT CURRENT TRANSFORMER

LZCK series split core current transformer is suitable forcurrent measurement and microcomputer protection of electrical equipment in 10KV and 35KV AC power system.It is widely used in compact fully insulated ring network switchgears such as ABB-Safe Ring/Safe Plus...and cable distribution boxes.The transformer can be directly installed at the inlet andoutlet cables.The slice is imported silicon material. Thesemicircular ring core and secondary windings arevacuum poured by insulated resin.

 

Gfuve 11kv 33kv High Voltage Split Core CT Current Transformer Lzck322-10

PARAMETERS

Technical parameters
StandardsIEC60044-1; IEC 61869-2; ANSI C57.13; NTC 2205; GB1208-2006
Rated primary current30-600A
Rated load≤10VA
Rated frequency50Hz or 60Hz
Rated secondary current5A or 1A
Rated short-time thermal current40kA, 1S
Rated continuous thermal current120%I1n
Secondary winding power-frequency voltage3kV, 1min
Instrument security factorFS≤10
Mechanical parameters
Dimensions (W×D×H) (mm)φ50xφ110x52
Weight (kg)1.6
Operating conditions
Operating temperature-35°C to +55°C
Daily average temp<+40°C
Altitude<3500 meters
ConditionNo existence of severely begrimed, erosive and radioactive gas in the air. Permission of long-term operation under rated current.

TECHNICAL DATA

TypeLZCK322-10LZCK322-10
PurposeMeasuring current transformerProtection current transformer
RatioAccuracy class and rated load(VA)Accuracy class and rated load(VA)
I1/I20.51310P1510P1010P5
30/1 11.5   
50/1 12  1.25
75/1 1.52.5 12
100/122.53 1.52.5
200/12.5  1.252.5 
300/13.75  1.252.5 
400/17.5  1.252.5 
500/110  1.253 
600/110  1.53 
50/5  2.5   
75/5  2.5   
100/52.5     
200/53.75     
300/55     
400/57.5   2.5 
500/57.5   2.5 
600/510   3.75 

SELECTION GUIDE

 ModelPrimary rated currentRated loadAperture (mm)Description (mm)Weight (kg)MaterialWater-proof
LZCK-55100-1500A≤10VAφ55180×138×522PC IP65
LMCK185-10300-3000A≤25VAφ185350×283×554.5PC IP65
LZCK310-10300-600A≤10VAφ50φ50 x φ110 x 321Resinsilicon case (option)
LZCK322-1030-600A≤10VAφ50φ50 x φ110 x 521.6Resinsilicon case (option)
LZCK350-1020-600A≤25VAφ50φ50 x φ110 x 1053.1Resinsilicon case (option)
LZCG530-1030-600A≤20VAφ45φ45 x φ120 x 652.1Resinsilicon case (option)

ORDERING INFORMATION

Be sure to the type, current ratio, accuracy class, rated load and use of the products when you plan to make a order. Special specifications could be customized.All kinds of different specifications and parameters current transformers can be made according to your needs.