Customization: | Available |
---|---|
Application: | Electronic |
Type: | Current Transformer |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Technical parameters | |
Standards | IEC60044-1; IEC 61869-2; NTC 2205; GB1208-2006; ANSI C57.13 |
Range of primary rated current | 20-600A |
Range of Rated load | ≤25VA |
Rated frequency | 50/60Hz |
Rated secondary current | 5A or 1A |
Rated short-time thermal current | 40kA, 1S |
Rated continuous thermal current | 120%I1n |
Secondary winding power frequency withstand voltage | 3kV, 1min |
Instrument security factor | (FS) <10 |
Mechanical parameters | |
Dimensions (W×D×H) (mm) | φ50xφ110x105 |
Weight (kg) | 3.1 |
Operating conditions | |
Operating temperature | -35°C to +55°C |
Daily average temp | < +40°C |
Altitude | <3500 meters |
Conditions | No existence of severely begrimed, erosive and radioactive gas in the air. Continuous working under the rated current is allowed. |
Type | LZCK350-10 | LZCK350-10 | LZCK350-10 | |||||||
Purpose | Measuring current transformer | Protection current transformer | Double winding current transformer | |||||||
Rtio | Accuracy class and rated load(VA) | Accuracy class and rated load(VA) | Composite accuracy class and rated load(VA) | |||||||
I1/I2 | 0.5 | 1 | 3 | 10P15 | 10P10 | 10P5 | 0.5 | 1 | 10P10 | 10P5 |
20/1 | 0.5 | 0.75 | ||||||||
30/1 | 0.5 | 1.5 | 0.75 | 1.25 | ||||||
50/1 | 1 | 2 | 1.25 | 2 | ||||||
75/1 | 2 | 2.5 | 3.75 | 1.25 | 2 | 3 | 2 | 1 | 2 | |
100/1 | 2.5 | 3.75 | 5 | 2 | 2.5 | 5 | 2 | 2.5 | 1.5 | 2.5 |
200/1 | 5 | 3 | 5 | 7.5 | 2.5 | 2 | ||||
300/1 | 10 | 3 | 5 | 7.5 | 3.75 | 2.5 | ||||
400/1 | 10 | 3 | 5 | 10 | 5 | 2.5 | ||||
500/1 | 25 | 3.75 | 6.25 | 10 | 5 | 2.5 | ||||
600/1 | 25 | 5 | 7.5 | 10 | 7.5 | 5 | ||||
Type | LZCK350-10 | LZCK350-10 | LZCK350-10 | |||||||
Purpose | Measuring current transformer | Protection current transformer | Double winding current transformer | |||||||
Rtio | Accuracy class and rated load(VA) | Accuracy class and rated load(VA) | Composite accuracy class and rated load(VA) | |||||||
50/5 | 2.5 | 2 | ||||||||
75/5 | 2.5 | 3 | ||||||||
100/5 | 2.5 | 3.75 | 5 | 2.5 | 2.5 | |||||
200/5 | 7.5 | 2.5 | 5 | 2.5 | ||||||
300/5 | 10 | 5 | 2 | 2.5 | ||||||
400/5 | 15 | 2.5 | 7.5 | 2.5 | 5 | |||||
500/5 | 25 | 2.5 | 7.5 | 2.5 | 5 | |||||
600/5 | 30 | 3.75 | 10 | 3 | 7.5 |
Model | Primary rated current |
Rated load | Aperture (mm) |
Description (mm) |
Weight (kg) |
Water-proof |
LZCK-55 | 100-1500A | ≤10VA | φ55 | 180×138×52 | 2 | IP65 |
LMCK185-10 | 300-3000A | ≤25VA | φ185 | 350×283×55 | 4.5 | IP65 |
LZCK310-10 | 300-600A | ≤10VA | φ50 | φ50 x φ110 x 32 | 1 | silicon case (option) |
LZCK322-10 | 30-600A | ≤10VA | φ50 | φ50 x φ110 x 52 | 1.6 | silicon case (option) |
LZCK350-10 | 20-600A | ≤25VA | φ50 | φ50 x φ110 x 105 | 3.1 | silicon case (option) |
LZCG530-10 | 30-600A | ≤20VA | φ45 | φ45 x φ120 x 65 | 5 | silicon case (option) |