T-206 Transformer dielectric loss tan delta tester can effectively find the overall damp, deterioration and partly defects of electrical equipment insulation, which are widely used in electrical manufacturing, electrical equipment installation, handover and preventive testing.
The anti-interference precision dielectric loss tan delta tester is used for on-site anti-interference, dielectric loss measurement or laboratory dielectric loss measurement. The transformer tan delta tester is an integrated structure with built-in dielectric loss bridge, variable variable frequency power supply, test transformer and standard capacitor, etc.. The instrument adopts frequency conversion anti-interference and Fourier transform digital filtering technology, fully automatic and intelligent measurement, and the measurement data is very stable under strong interference. The result of measurement is displayed by large screen display, and the instrument comes with micro printer to print and print test results.






| Electrical parameters | |
| Power supply | Single phase AC 220V±10% or 110V±10%, 50/60Hz AC |
| Accuracy | Cx: + (reading * 1%+1pF)TG Delta: + (reading * 1%+0.00040) |
| Anti-interference index | Frequency conversion anti-interference, can achieve the accuracy under 200% interference |
| Capacitance range | Internal applied high voltage: 3pF ~ 60000pF/10kV 60pF to 1mu F/0.5kV External applied high voltage: 3pF to 1.5F/10kV 60pF to 30mu F/0.5kV |
| Resolution | Maximum 0.001pF, 4 bit significant digits |
| TG delta range | No limit, resolution 0.001%, capacitance, inductance, resistance, three kinds of test products, automatic identification. |
| Test current range | 10 A to 5A |
| Internal applied high voltage | Set voltage range: 0-12kV |
| Maximum output current | 200mA |
| Lifting mode | Continuous smooth adjustment |
| Voltage accuracy | + (1%×readings+10V) |
| Voltage resolution | 0.1V |
| Test frequency | 45, 50, 55, 60, 65Hz single frequency 45/55Hz, 55/65Hz, 47.5/52.5Hz automatic dual frequency conversion |
| Frequency accuracy | 0.01Hz |
| External applied high voltage | Positive and reverse wiring, the maximum test current 5A |
| CVT self excitation measurement | Output voltage 3 ~ 50V, output current 3 ~ 30A C1/C2 simultaneous measurements, high-voltage wiring can be mopping |
| CVT ratio measurement | Change ratio measurement accuracy: +reading×1% ratio, measuring range: 10~99999 Phase measurement accuracy: +0.02° phase measurement range: 0~ 359.99 ° |
| High voltage dielectric loss | Support frequency conversion and vibration supply, high voltage dielectric loss |
| Real time clock | Time and date display in real time |
| Internal storage | 100 sets of measurement data can be stored inside the instrument |
| U disk | Supports U disk storage |
| LCD | 5.7″black and white LCD display |
| Cable length | High voltage cable 12m, signal cable 10m, CVT cable 8m; |
| Communication port | RS232, USB |
| Degree of protection | IP42 |
| Printer | Built-in 58mm thermal printer |
| Standard | IEC61010-1, IEC61326-1 |
| Mechanical parameters | |
| Dimension (L×W×H)(mm) | 368x288x280 |
| Weight (kg) | 22 |
| Environmental conditions | |
| Operating temperature | -10°C to 50°C |
| Storage temperature | -20°C to 70°C |
| Relative humidity | ≤85%RH |