• 0.05% Accuracy Portable Current Transformer Test Set
  • 0.05% Accuracy Portable Current Transformer Test Set
  • 0.05% Accuracy Portable Current Transformer Test Set
  • 0.05% Accuracy Portable Current Transformer Test Set
  • 0.05% Accuracy Portable Current Transformer Test Set

0.05% Accuracy Portable Current Transformer Test Set

Application: Electromagnetic Instrument
Power: Electricity
Certification: FDA, CE, IAF, CCC
Voltage Output: 0-2500V
Current Output: 0-1000A
LCD Display: With LCD Display
Customization:
Gold Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
GF106
Customized
Customized
Power Supply
AC 220V±10% or AC 110V±10%, 50/60Hz
Automatic Frequency Variation Range
0.1-60Hz
CT Ratio
1-30000
PT Ratio
1-10000
Phase Error
4min
Burden
5va-1000va
Keyword
Current Transformer Test Set
Model
0.05 Accuracy CT Test Set
GF106
0.05 Current Transformer Test Set
Types
CT PT Tester
Transport Package
Standard Export Wooden Box
Specification
GF106, 0.05%, 1000A/2500V
Trademark
GFUVE
Origin
Beijing, China
Production Capacity
10000pieces/Month

Product Description

GF106 0.05 accuracy portable current transformer test set

GF106 0.05 accuracy of current transformer test set is mainly used for field testing, it can finish the measurements (M) and protection (P) class CT, PT and TYP class CT. Adopt LCD, self-equipped mini type printer supporting field printing; supporting to use USB flash disk to dump data, with simple and convenient operation.

Features
Steady and transient state characteristic tests of various types of CT/PT
The use of advanced power technology, the test knee point reaches up to 40kV
No external other auxiliary equipment, stand-alone to complete all test items
CT test, easy to test, all the tests are using the same wire connection except the load test
It carries with thermal printer, so it can print test results on site
Parameters such as knee point current and voltage
Parameters such as 10% error curve, 5% error curve
The device can store 3000 groups of test data which would not be lost if the device is power off.
The data can be displayed and analyzed after the test, or transferred to PC through USB disk and produce a Word file report
Portability: weight < 12kg

FUNCTION
I. Current Transformer (CT) II. Voltage Transformer (PT)
1.  Magnetization curve 1.  Excitation characteristic test
2.  Transformation ratio test 2.  Transformation ratio test
3.  Polarity 3.  Polarity
4.  5% and 10% error curve 4.  Ratio error, phases
5.  Current Injecting 5.  Degauss
6.  Degauss 6.  Calculation of knee point value
7.  Ratio error, phases 7.  Actual secondary load (burden), test (burden)
8.  Automatic calculation of excitation knee point value 8.  Resistance test
9.  Actual secondary load test (burden) (load test)
10.  Resistance test
11.  Secondary winding time constant (Ts)
12.  Remanence coefficient (Kr)
13.  Transient dimensioning factor (Ktd)
14.  Peak instantaneous error (Er)
15.  Magnetizing inductance (LU)

Parameters
Electrical parameters
Accuracy 0.05%, 0.1%
Power supply AC 220V±10% or AC 110V±10%, 50/60Hz
Excitation output voltage 0-220Vrms
Excitation output current 0-5Arms (20A peak-value)
Automatic frequency variation range 0.1-60Hz
Equivalent excitation voltage ≤5000V
Accuracy ≤0.5% (0.2%RD+0.3%RG)
Secondary winding DC resistance measurement Range 0.1-300Ω
Accuracy ≤0.5% (0.2%RD+0.3%RG)
Secondary actual load measurement Range 5VA-1000VA
Accuracy ≤0.5% (0.2%RD+0.3%RG)±0.1VA
CT/PT phase error measurement Accuracy ±4min
Resolution 0.01min
CT ratio error measurement Range 1-30000
Accuracy ≤0.5%
PT ratio error measurement Range 1-10000
Accuracy ≤0.5%
Standards
Reference standards GB1207-2006, GB1208-2006, GB16847-1997
IEC60044-1, IEC60044-6, IEC61869-2-2012
Safety standards GB 4793.1-2007
EMC EMC standard 89/336/EEC
FCC Subpart B of Part 15 Class A
IEC 1000-4-2/3/4/6
Mechanical parameters
Overall dimension (L x W x H) (mm) 410 x 250 x 300 
Weight (kg)   ≤10 
Environmental conditions
Relative humidity    90RH%
Operating temperature -10°C to +40°C
Altitude ≤2000m
Main functions
The test items mainly include
Steady Transient
excitation characteristic secondary winding time constant (Ts)
transformation ratio remanence coefficient (Kr)
polarity transient dimensioning factor (Ktd)
ratio error peak instantaneous error (Er)
phases magnetizing inductance (LU)
5% and 10% error curves other parameters
resistance
secondary load
http://guangfuhui.en.made-in-china.com

Photo
0.05% Accuracy Portable Current Transformer Test Set

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now