|
Still deciding? Get samples of $ !
Request Sample
|
| Customization: | Available |
|---|---|
| After-sales Service: | 24 Hour Service |
| Warranty: | 2 Years |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency

Renewable power plants;
Electricity power company;
Photovoltaic power station;
Uninterruptible power supply;
Uninterruptible power supply in healthcare;
Recording transients of switching manoeuvers;
Effects of power quality issues on living and working environment;
Factory;
Power quality;
Power generation;
Wind power plant;
Oil, Gas company;
Power distribution;
Hydroelectric power;
Power quality reports;
True RMS values of voltages and currents;
Three phase unbalance(current and voltage);
Measurement of each harmonic up to order 50;
Each phase and total active, reactive, apparent power;
Each phase and total active, reactive, apparent energy;
Power factors (PF) and displacement factors (DPF or COSΦ);
Minimum and maximum half-cycle RMS current and voltage values;
Waveform real-time display (4 channels voltage/4 channels current);
Bar charts show harmonic ratios of current and voltage of each phase;
Alarm function;
Snapshot function;
Transformer K factor;
Vector diagram display;
Inrush current monitoring;
Transient capture function;
Short-term voltage flicker (PST);
Total harmonic distortion (THD);
The DC components of voltages;
Peak current and voltage values;
Trend chart recording and storing function;
| Electrical parameters | |
|---|---|
| Function | Analysis and diagnosis on all the voltage, current, power, energy, harmonic, each phase electric parameters etc. |
| Accuracy | 0.5% |
| Power Supply | Rechargeable lithium-ion battery 10000mAh. |
| Input channels | 4 channel voltage, 4 channel current |
| Rated voltage range(U1 U2 U3 U4 Un) | 0-1000V AC/DC (phase voltage) |
| Rated voltage range(U1 U2 U3 U4) | 0-2000V AC/DC (line voltage) |
| Rated current range(I1 I2 I3 I4) | 10A/100A/1000A/6000A |
| Frequency | 40-70Hz |
| Phase shift | 0 - 1 |
| Harmonic | 2 - 50 times |
| Total harmonic distortion | 2 - 50 times, each phase |
| Voltage unbalance | 0.0%~ 100% |
| Three phases unbalance | Yes |
| Parameters of electricity | W, VA, Var, PF, DPF, cosφ, tanφ. |
| Energy parameters | Wh, Varh, Vah. |
| Number of Transient records | 150 sets |
| Voltage flicker | Yes |
| Record | 300 days(simultaneous recording 20 parameters, record one point every 5 seconds) |
| Min/Max value | Yes |
| LCD display | 5.6 inch color TFT LCD, 640×480, 4-bit LCD display, gray screen backlight |
| Alarm Function | 40 different types of parameter selections, 12,800 sets alarm logs. |
| Peak value | Yes |
| Vector diagram display | Yes |
| Snapshots | Yes, 60pcs |
| Storage card | 2G |
| Communication | USB Port |
| Alarm Function | Yes |
| Power Consumption | Current consumption of normal test 490 mA, continuous working for 10 hours. |
| Insulation Resistance | ≥10MΩ (Between instrument wiring and shell) |
| Withstand voltage | AC3kV/50Hz 1min (between instrument wiring and shell) |
| Test cable | voltge cable 3m(5pcs), Crocodile clips(5pcs) |
| PC software | Yes |
| Standard | IEC61010-1, IEC61010-2-31, IEC60529(IP54), pollution grade 2, 1000V Cat III / 600V CAT IV, EN/IEC 61326; IEC 61000-4-30; IEC 61000-4-7, IEEE 519; IEC 61000-4-15; IEEE 1459; EN 50160 |
| Mechanical parameters | |
| Dimensions (W×D×H) (mm) | 277.2x227.5x153 |
| Weight (kg) | 2.4 |
| Environmental conditions | |
| Operating temperature | -10°C to +50°C |
| Storage temperature | -40°C to 70°C |
| Relative humidity | ≤90%RH |