Customization: | Available |
---|---|
After-sales Service: | 24hour |
Warranty: | 3years |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Register test
Harmonics test
Energy meter accuracy test
Repeatability of error test
Measuring the distortion factor
User friendly menu guided operation
Energy dosing with built-in current source
Measuring mechanical meter and electric meter
Measuring frequency, phase shift and power factor
Automatic operation without need of an external PC
Easy verification and analysis of meter installations
Three phase ballance test and Three phase unballance test
Testing all kinds of energy meter in 1P2W, 1P3W, 3P3W, 3P4W
Especially configured USB stick for storage of customer data
Power and energy measurements for active, reactive and apparent power
Harmonic spectrum analysis for voltage and current up to the 63nd order
Vector diagram display and phase sequence indication on integrated colored screen
Weight light 12.8Kg
0-120A/0-500V/40-70Hz
7 inch TFT touch screen
Test by automatic or manual
Accuracy class 0.02 or 0.05
Start testing and creep testing
Recorder 500 sets energy meter data
Display all electrical parameters on one screen
Reference standard and current source integrated
Overload, short circuit, open circuit protection
Electrical parameters | |
---|---|
Accuracy | 0.02%, 0.05%, 0.1% |
Power supply | One phase AC 100-265V, frequency 50/60Hz. |
AC voltage output | |
Range (U1, U2, U3) | 0-600V; 0-500V; 0-380V; 0-300V; |
Adjustment range | (0-120)%RG(1) |
Adjustment fineness | 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional. |
Stability | 0.01%/120s |
Distortion | 0.3% (Non-capacitive load) |
Output load | Each phase 25VA |
Accuracy | 0.02%RG or 0.05%RG |
AC current output | |
Range (I1, I2, I3) | 0-6A; 0-12A; 0-20A; 0-50A; 0-120A; |
Adjustment range | (0-100)%RG |
Adjustment fineness | 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional. |
Stability | <0.01%/120s |
Distortion | ≤0.3% (Non-capacitive load) |
Max output load | 20VA or 50VA or 100VA; |
Accuracy | 0.02%RG or 0.05%RG |
Power measurement | |
Active power output stability | <0.01%RG/120s |
Reactive power output stability | <0.02%RG/120s |
Active power measuring accuracy | 0.02%RG or 0.05%RG |
Reactive power measuring accuracy | 0.05%RG or 0.1%RG |
Phase output | |
Output adjustment range | 0°-359.999° |
Output adjustment fineness | 10, 1, 0.1, 0.01 as optional. |
Resolution | 0.01° |
Accuracy | 0.015° |
Power factor | |
Adjustment range | -1 ~ 0 ~ 1 |
Resolution | 0.0001 |
Measurement accuracy | 0.0005 |
Frequency measurement | |
Range | 40Hz-70Hz |
Resolution | 0.001Hz |
Accuracy | 0.002Hz |
Voltage/current/harmonic setting | |
Harmonic number | 2-63times |
Harmonic content | 0-40% |
Harmonic phase | 0-359.99 |
Harmonic setting accuracy | (10%±0.1%)RD(2) |
Power energy measurement error | |
Active power energy | 0.02%RG or 0.05%RG |
Reactive power energy | 0.05%RG or 0.1%RG |
Power pulse output | |
Power pulse type | Active pulse, reactive pulse |
Active power pulse output | 5V, 10mA |
Power pulse input | |
Energy pulse type | Support active and reactive pulse, the highest frequency power pulse input is 200K. |
Pulse input channel | 1, 3 optional |
Communication port | |
Communication port | RS232, USB2.0 |
Standard | |
Standard | IEC62053-21,22,23; IEC60736; ANSI C12.20-2002; JJG 597-2005; JJG596-2012; JJG 1085-2013; JJF 68-2019; DL/T 826-2002; DL/T 1478-2015; DL/T 448-2016 |
Safety | |
Isolation protection | IEC61010-1:2001 |
Measurement category | 300V CAT III, 600V CAT II |
Degree of protection | IP42 |
Declaration of conformity | CE & CNAS certified |
Mechanical parameters | |
Dimensions (W×D×H)(mm) | 495 x 390 x 195 |
Weight (kg) | 12.8, 22.8 |
Environmental conditions | |
Ambient temperature | -10°C to +50°C |
Relative humidity | 35%-85% |
(1)RG means range, the same as below; (2)RD means the setted harmonic content, harmonic can be a single output, also multiple output. |
NO. | Accuracy | Voltage range | Current range | Weight |
---|---|---|---|---|
302D112001 | 0.1% | 0-500V | 0-120A | 22KG |
302D1120005 | 0.05% | 0-500V | 0-120A | 22KG |
302D1120002 | 0.02% | 0-500V | 0-120A | 22KG |
302D15001 | 0.1% | 0-500V | 0-50A | 18KG |
302D150005 | 0.05% | 0-500V | 0-50A | 18KG |
302D150002 | 0.02% | 0-500V | 0-50A | 18KG |
302D12001 | 0.1% | 0-500V | 0-20A | 15.8KG |
302D120005 | 0.05% | 0-500V | 0-20A | 15.8KG |
302D120002 | 0.02% | 0-500V | 0-20A | 15.8KG |
302D11201 | 0.1% | 0-380V | 0-12A | 12.8KG |
302D112005 | 0.05% | 0-380V | 0-12A | 12.8KG |
302D112002 | 0.02% | 0-380V | 0-12A | 12.8KG |
302D1601 | 0.1% | 0-300V | 0-6A | 8KG |
302D16005 | 0.05% | 0-300V | 0-6A | 8KG |
302D16002 | 0.02% | 0-300V | 0-6A | 8KG |