100A 11kv 33kv Split Core CT Current Transformer

  • Audited Supplier
  • 14 yrs

Contact Supplier

Product Highlights

  • Split Core Design: Allows direct installation on existing cables without power interruption.
  • Wide Current Range: Rated primary current spans from 30A to 600A for versatile applications.
  • Multiple Accuracy Classes: Available in 0.5, 1, 3, 10P15, 10P10, and 10P5 for measurement and protection.
  • Vacuum Poured Resin: Secondary windings vacuum poured by insulated resin for superior insulation.
  • Compact Installation: Suitable for compact fully insulated ring network switchgears and cable boxes.
  • High Thermal Current: Rated short-time thermal current of 40kA for 1 second ensures safety.
  • Global Standards Compliance: Meets IEC60044-1, IEC 61869-2, ANSI C57.13, and NTC 2205 standards.

Product Images of 100A 11kv 33kv Split Core CT Current Transformer

100A 11kv 33kv Split Core CT Current Transformer
100A 11kv 33kv Split Core CT Current Transformer pictures & photos
100A 11kv 33kv Split Core CT Current Transformer
100A 11kv 33kv Split Core CT Current Transformer pictures & photos
100A 11kv 33kv Split Core CT Current Transformer
100A 11kv 33kv Split Core CT Current Transformer pictures & photos
100A 11kv 33kv Split Core CT Current Transformer
100A 11kv 33kv Split Core CT Current Transformer pictures & photos
100A 11kv 33kv Split Core CT Current Transformer
100A 11kv 33kv Split Core CT Current Transformer pictures & photos
100A 11kv 33kv Split Core CT Current Transformer
100A 11kv 33kv Split Core CT Current Transformer pictures & photos
100A 11kv 33kv Split Core CT Current Transformer
  • 100A 11kv 33kv Split Core CT Current Transformer
  • 100A 11kv 33kv Split Core CT Current Transformer
    100A 11kv 33kv Split Core CT Current Transformer
  • 100A 11kv 33kv Split Core CT Current Transformer
    100A 11kv 33kv Split Core CT Current Transformer
  • 100A 11kv 33kv Split Core CT Current Transformer
    100A 11kv 33kv Split Core CT Current Transformer
  • 100A 11kv 33kv Split Core CT Current Transformer
    100A 11kv 33kv Split Core CT Current Transformer
  • 100A 11kv 33kv Split Core CT Current Transformer
    100A 11kv 33kv Split Core CT Current Transformer
  • 100A 11kv 33kv Split Core CT Current Transformer
    100A 11kv 33kv Split Core CT Current Transformer

Find Similar Products

Product Description

100A 11KV 33KV Split Core Ct Current Transformer
100A 11kv 33kv Split Core CT Current Transformer

LZCK series split core current transformer is suitable forcurrent measurement and microcomputer protection of electrical equipment in 10KV and 35KV AC power system.It is widely used in compact fully insulated ring network switchgears such as ABB-Safe Ring/Safe Plus...and cable distribution boxes.The transformer can be directly installed at the inlet andoutlet cables.The slice is imported silicon material. Thesemicircular ring core and secondary windings arevacuum poured by insulated resin.
Parameters
Technical parameters
Standards IEC60044-1; IEC 61869-2; ANSI C57.13; NTC 2205; GB1208-2006
Rated primary current 30-600A
Rated load ≤10VA
Rated frequency 50Hz or 60Hz
Rated secondary current 5A or 1A
Rated short-time thermal current 40kA, 1S
Rated continuous thermal current 120%I1n
Secondary winding power-frequency voltage 3kV, 1min
Instrument security factor FS≤10
Mechanical parameters
Dimensions (W×D×H) (mm) φ50xφ110x52
Weight (kg) 1.6
Operating conditions
Operating temperature -35°C to +55°C
Daily average temp <+40°C
Altitude <3500 meters
Condition No existence of severely begrimed, erosive and radioactive gas in the air. Permission of long-term operation under rated current.
Technical data
Type LZCK322-10 LZCK322-10
Purpose Measuring current transformer Protection current transformer
Ratio Accuracy class and rated load(VA) Accuracy class and rated load(VA)
I1/I2 0.5 1 3 10P15 10P10 10P5
30/1   1 1.5      
50/1   1 2     1.25
75/1   1.5 2.5   1 2
100/1 2 2.5 3   1.5 2.5
200/1 2.5     1.25 2.5  
300/1 3.75     1.25 2.5  
400/1 7.5     1.25 2.5  
500/1 10     1.25 3  
600/1 10     1.5 3  
50/5     2.5      
75/5     2.5      
100/5 2.5          
200/5 3.75          
300/5 5          
400/5 7.5       2.5  
500/5 7.5       2.5  
600/5 10       3.75  
Selection guide
 Model Primary rated current Rated load Aperture (mm) Description (mm) Weight (kg) Material Water-proof
LZCK-55 100-1500A ≤10VA φ55 180×138×52 2 PC  IP65
LMCK185-10 300-3000A ≤25VA φ185 350×283×55 4.5 PC  IP65
LZCK310-10 300-600A ≤10VA φ50 φ50 x φ110 x 32 1 Resin silicon case (option)
LZCK322-10 30-600A ≤10VA φ50 φ50 x φ110 x 52 1.6 Resin silicon case (option)
LZCK350-10 20-600A ≤25VA φ50 φ50 x φ110 x 105 3.1 Resin silicon case (option)
LZCG530-10 30-600A ≤20VA φ45 φ45 x φ120 x 65 2.1 Resin silicon case (option)

About the Supplier

Watch Video
Watch Video
Beijing GFUVE Electronics Co., Ltd.
Beijing GFUVE Electronics Co., Ltd.
Beijing GFUVE Electronics Co., Ltd.
Beijing GFUVE Electronics Co., Ltd.
Beijing GFUVE Electronics Co., Ltd.
Beijing GFUVE Electronics Co., Ltd.
Beijing GFUVE Electronics Co., Ltd.
Beijing GFUVE Electronics Co., Ltd.

About Our Factory & Business Background

Address
Bldg. 2-1111, Joy Mansion, No. 99 Chaoyang North Road, Chaoyang District, Beijing, China
Terms of Payment
LC, T/T, PayPal, Western Union
International Commercial Terms(Incoterms)
FOB, CIF, FCA, EXW
Average Lead Time
Peak Season Lead Time: one month
Off Season Lead Time: within 15 workdays
Nearest Port
TIANJING

Our Production Capability & Technical Expertise

Main Products
Current Transformer, Energy Meter Calibration, Power Quality Analyzer, Test Equipment, CT PT Analyzer, Relay Test Equipment, Split Core Current Transformer, Current Probe, Voltage Transformer, Power Meter

Our Industry Experience & Global Business Record

Export Year
2010-08-01
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe

FAQ

What is the split core current transformer used for?
It is suitable for current measurement and microcomputer protection in 10KV and 35KV AC power systems.
Can this transformer be installed on existing cables?
Yes, the split core design allows direct installation at cable inlets and outlets without disconnecting.
What are the available accuracy classes?
It offers accuracy classes of 0.5, 1, 3, 10P15, 10P10, and 10P5 for both measuring and protection purposes.
What is the rated primary current range?
The rated primary current ranges from 30A to 600A depending on the specific model selected.
What standards does this product comply with?
It complies with IEC60044-1, IEC 61869-2, ANSI C57.13, NTC 2205, and GB1208-2006.
Is the transformer suitable for outdoor use?
It is designed for indoor operation but requires conditions with no severely begrimed, erosive, or radioactive gas.
What is the lead time for this product?
Lead time is within 15 workdays during off-peak season and one month during peak season.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

Product Groups

Product Catalogs