Customization: | Available |
---|---|
After-sales Service: | 24 Hour Service |
Warranty: | 2 Years |
Still deciding? Get samples of US$ 2000/Set
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Selection method;
3-pole measurement;
Testing Soil resistivity;
Double clamp method;
AC voltage measurement;
Simple 2-pole measurement;
Precise 4-pole measurement;
Measurement of earth voltage;
Measure grounding resistance;
AC leakage current measurement;
Accuracy 2%;
AC voltage 0-100V;
With gray backlight;
DC voltage 0-1000V;
With IP65 protection;
Recorder 500 sets data;
AC current measurement 0-1000A;
Soil Resistivity (ρ) 0.00Ωm - 9999kΩm;
Earth resistance range 0.01Ω - 30.00kΩ;
Electrical parameters | |
---|---|
Function | Measure grounding resistance, soil resistivity; Measurement of earth voltage, AC voltage, leakage current of AC current |
Accuracy | 2% |
Power Supply | DC 6V(4.5AH battery, continuous standby for 300 hours ) |
Backlight | White screen backlight, suitable for dim places |
Measuring Mode | Precise 4-pole measurement, 3-pole measurement, simple 2-pole measurement, selection method, double clamp method measure grounding resistance |
Measuring Method | 2/3/4 pole method: change-pole method, measurement current 20mA Max Selection method: change-pole method, measurement current 20mA Max Double clamp method: disconnect mutual inductance method, measurement current 1mA Max Soil Resistivity: 4-pole measurement (Wenner method) DC resistance: change-pole method AC current: mutual inductance method Earth Voltage: average rectification(between P(S)-ES) |
Measuring Rate | AC current: about 2 times/second Voltage to ground: about 2 times/second Earth resistance, soil resistivity: about 7 seconds/time |
Measuring Times | Over 5000 times (Short-circuit test, interval time should be at least 30 seconds) |
Earth resistance range | 0Ω - 30.00KΩ |
Resolution | 0.01Ω/0.1Ω/1Ω/10Ω |
Soil resistivity range | 0.00Ωm - 9999kΩm |
Resolution | 0.01Ωm/0.1Ωm/1Ωm/10Ωm/100Ωm/1kΩm |
Earth Voltage Range | 0 - 100V; Resolution: 0.01V |
Clamp AC current Range | 0 - 1000A; Resolution: 0.1mA |
Test Voltage Wave | Sine wave |
Test Frequency | 128Hz |
Short-circuit Test Current | AC 20mA max |
Open-circuit Test Current | AC 40V max |
Electrode Distance Range | set 1m-100m |
Backlight | Yes |
LCD display | 108mm×65mm, 4-bit LCD display, gray screen backlight |
Communication | USB Port |
Data Storage | 500 GROUPS |
Alarm Function | Yes |
Power Consumption | Standby: about 25mA Max(Backlight shut off) Boot 28mA Max(without backlight) Measurement: about 120mA Max(Backlight shut off) |
Overload Protection | Earth resistance: between each interfaces of C(H)-E, P(S)-ES, AC 280V/3 seconds |
Insulation Resistance | Over 20MΩ (between circuit and enclosure it is 500V) |
Withstand voltage | AC 3700V/rms. (Between circuit and enclosure) |
Standard | IEC61010-1 (CAT III 300V, CAT IV 150V, Pollution 2), IEC61010-031; IEC61557-1 (Earth resistance); IEC61557-5 (Soil resistivity); JJG 366-2004(Grounding resistance meter) JJG 1054-2009(Clamp grounding resistance meter) IEC61326(EMC) |
Mechanical parameters | |
Dimensions (L×W×H) (mm) | 277.2mm×227.5mm×153mm |
Size of clamp(L×W×H) (mm) | 101mm×27mm×214mm |
Standard Test Wire | 4 wires: each for red 15m, black 15m, yellow 10m, and green 10m |
Simple Test Wire | 2 wires: each for red 1.5m and black 1.5m |
Auxiliary Grounding Rod | 4 wires: Φ10mm×150mm Over 5000 times (Short-circuit test, interval time should be at least 30 seconds) |
1000A current clamp(Optional) | 2pcs :1 blue-black plug and 1 red-black. 50mm diameter,1000:1, 2m |
Weight (kg) | Total weight: 8.05kg (including package) Tester: 2430g (including battery) Testing wires: 940g Auxiliary grounding rods: 935g (4pcs) |
Environmental conditions | |
Operating Temperature | -10°C to +50°C |
Storage Temperature | -40°C to 70°C |
Relative humidity | ≤90%RH |