Advanced Ground Earth Resistance Tester

Product Details
Customization: Available
Warranty: 3 Years
Display Type: Analogue and Digital
Still deciding? Get samples of US$ 1000/Set
Request Sample
Diamond Member Since 2013

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
5000000 RMB
Plant Area
>2000 square meters
  • Advanced Ground Earth Resistance Tester
  • Advanced Ground Earth Resistance Tester
  • Advanced Ground Earth Resistance Tester
  • Advanced Ground Earth Resistance Tester
  • Advanced Ground Earth Resistance Tester
  • Advanced Ground Earth Resistance Tester
Find Similar Products

Basic Info.

Model NO.
T-3630E
Certification
RoHS, CE
Customized
Customized
Accuracy
2%
Earth Resistance Range
0Ω - 30.00KΩ
Transport Package
Wooden Box
Specification
277*277*153
Origin
China

Product Description

ADVANCED MULTIFUNCTION EARTH GROUND RESISTANCE TESTER

T-3630E multifunction earth ground resistance meter is composed of host machine, monitoring software, testing wires, auxiliary ground pillars, communication wires and others. The large LCD display of host machine is with blue backlight and bar graph indicating that can be seen clearly. At the same time it can store 100 sets of data, fulfilling historical inquiry and online real-time monitoring through monitoring software, dynamic display, and alarm indicator, auto-shut down and with the functions like historical data access, reading, preservation, report forms, printing and so on.

Advanced Ground Earth Resistance Tester
 
  FEATURES

Accuracy 2%;

AC voltage 0-100V;

With gray backlight;

DC voltage 0-1000V;

With IP65 protection;

Recorder 500 sets data;

AC current measurement 0-1000A;

Soil Resistivity (ρ) 0.00Ωm - 9999kΩm;

Earth resistance range 0.01Ω - 30.00kΩ;

 PARAMETERS

 

Electrical parameters
Function Measure grounding resistance, soil resistivity; Measurement of earth voltage, AC voltage, leakage current of AC current
Accuracy 2%
Power Supply DC 6V(4.5AH battery, continuous standby for 300 hours )
Backlight White screen backlight, suitable for dim places
Measuring Mode Precise 4-pole measurement, 3-pole measurement, simple 2-pole measurement, selection method, double clamp method measure grounding resistance
Measuring Method 2/3/4 pole method: change-pole method, measurement current 20mA Max
Selection method: change-pole method, measurement current 20mA Max
Double clamp method: disconnect mutual inductance method, measurement current 1mA Max
Soil Resistivity: 4-pole measurement (Wenner method)
DC resistance: change-pole method
AC current: mutual inductance method
Earth Voltage: average rectification(between P(S)-ES)
Measuring Rate AC current: about 2 times/second
Voltage to ground: about 2 times/second
Earth resistance, soil resistivity: about 7 seconds/time
Measuring Times Over 5000 times (Short-circuit test, interval time should be at least 30 seconds)
Earth resistance range 0Ω - 30.00KΩ
Resolution 0.01Ω/0.1Ω/1Ω/10Ω
Soil resistivity range 0.00Ωm - 9999kΩm
Resolution 0.01Ωm/0.1Ωm/1Ωm/10Ωm/100Ωm/1kΩm
Earth Voltage Range 0 - 100V; Resolution: 0.01V
Clamp AC current Range 0 - 1000A; Resolution: 0.1mA
Test Voltage Wave Sine wave
Test Frequency 128Hz
Short-circuit Test Current AC 20mA max
Open-circuit Test Current AC 40V max
Electrode Distance Range set 1m-100m
Backlight Yes
LCD display 108mm×65mm, 4-bit LCD display, gray screen backlight
Communication USB Port
Data Storage 500 GROUPS
Alarm Function Yes
Power Consumption Standby: about 25mA Max(Backlight shut off)
Boot 28mA Max(without backlight)
Measurement: about 120mA Max(Backlight shut off)
Overload Protection Earth resistance: between each interfaces of C(H)-E, P(S)-ES, AC 280V/3 seconds
Insulation Resistance Over 20MΩ (between circuit and enclosure it is 500V)
Withstand voltage AC 3700V/rms. (Between circuit and enclosure)
Standard IEC61010-1 (CAT 300V, CAT IV 150V, Pollution 2), IEC61010-031;
IEC61557-1 (Earth resistance);
IEC61557-5 (Soil resistivity);
JJG 366-2004(Grounding resistance meter)
JJG 1054-2009(Clamp grounding resistance meter)
IEC61326(EMC)
Mechanical parameters
Dimensions (L×W×H) (mm) 277.2mm×227.5mm×153mm
Size of clamp(L×W×H) (mm) 101mm×27mm×214mm
Standard Test Wire 4 wires: each for red 15m, black 15m, yellow 10m, and green 10m
Simple Test Wire 2 wires: each for red 1.5m and black 1.5m
Auxiliary Grounding Rod 4 wires: Φ10mm×150mm Over 5000 times (Short-circuit test, interval time should be at least 30 seconds)
1000A current clamp(Optional) 2pcs :1 blue-black plug and 1 red-black. 50mm diameter,1000:1, 2m
Weight (kg) Total weight: 8.05kg (including package)
Tester: 2430g (including battery)
Testing wires: 940g
Auxiliary grounding rods: 935g (4pcs)
Environmental conditions
Operating Temperature -10°C to +50°C
Storage Temperature -40°C to 70°C
Relative humidity ≤90%RH
 
Advanced Ground Earth Resistance Tester