GF102 Portable Single Phase Energy Meter Tester

Product Details
Customization: Available
After-sales Service: 24hour
Warranty: 3years
Diamond Member Since 2013

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
5000000 RMB
Plant Area
>2000 square meters
  • GF102 Portable Single Phase Energy Meter Tester
  • GF102 Portable Single Phase Energy Meter Tester
  • GF102 Portable Single Phase Energy Meter Tester
  • GF102 Portable Single Phase Energy Meter Tester
  • GF102 Portable Single Phase Energy Meter Tester
Find Similar Products
  • Overview
  • Product Description
  • FEATURES
  • Specifications
  • PARAMETERS
Overview

Basic Info.

Model NO.
GF102
Accuracy Class
0.02%, 0.05%, 0.1%
Power Supply
One Phase AC 100-265V, Frequency 50/60Hz.
Voltage Output
57.7V, 100V, 220V, 380V; Max 600V
Current Output
200mA, 1A, 5A, 20A, 100A; Max 120A
Transport Package
Wooden Case
Specification
455 x 440 x 150
Trademark
GFUVE
Origin
China
Production Capacity
5000

Product Description

Product Description

 

GF102 series portable single phase energy meter test bench used to test 1pc or 3pcs single phase energy meter or AC meter at same time. Adopt mature signal synthetic and power amplifier technology, high precision voltage source and current source output from 120A/600V. Widely used in lab and field, and then as single phase standard source. It is suite for electricity meter manufacturing enterprises, scientific research institutes, metrological service institutions, electric power companies etc.
FEATURES

3 channel voltage isolation

Test by automatic or manual

Accuracy class 0.02/0.05/0.1

7 inch TFT touch color screen

Start testing and creep testing

Test 3pcs meter synchronously

0-120A, 0-600V, 40-70Hz, 0-360.000

Recorder 1000 sets energy meter data

Overload, short circuit, open circuit protection

Reference standard and power source integrated

 
Specifications

Measuring the distortion factor;

Multi load point setting output;

Testing meter installations in 1P2W;

Many plan auto test for energy meter error;

Vector representation of the measuring values;

Measuring frequency, phase shift and power factor;

Measuring mechanical meter and electric meter error;

Energy dosing with built-in current source and voltage source;

Harmonic spectrum analysis for voltage and current up to the 63nd order;

Power and energy measurements for active, reactive and apparent power;

PARAMETERS
Accuracy class 0.02%, 0.05%, 0.1%
Power supply One phase AC 100-265V, frequency 50/60Hz.
AC voltage output
Range 57.7V, 100V, 220V, 380V; max 600V
Adjustment range (0-120)%RG(1)
Adjustment fineness 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional.
Stability 0.01%/120s
Distortion 0.1% (Non-capacitive load)
Output load 25VA or 50VA
Measuring accuracy 0.02%RG or 0.05%RG
AC current output
Range 200mA, 1A, 5A, 20A, 100A; max 120A
Adjustment range (0-120)%RG
Adjustment fineness 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional.
Stability <0.01%/120s
Distortion ≤0.1% (Non-capacitive load)
Output load 50VA or 100VA
Accuracy 0.02%RG or 0.05%RG
Power output
Active power output stability <0.01%RG/120s
Reactive power output stability <0.02%RG/120s
Active power measuring accuracy 0.02%RG or 0.05%RG
Reactive power measuring accuracy 0.05%RG or 0.1%RG
Phase output
Output adjustment range 0°-359.999°
Output adjustment fineness 10,1, 0.1, 0.01 as optional.
Resolution 0.01°
Accuracy 0.02°
Power factor
Adjustment range -1 ~ 0 ~ 1
Resolution 0.0001
Measurement accuracy 0.0005
Frequency output
Adjustment range 40Hz-70Hz
Output adjustment fineness 5Hz, 1Hz, 0.1Hz, 0.01Hz as optional.
Resolution 0.001Hz
Accuracy 0.002Hz
Voltage/Current/Harmonic setting
Harmonic number 2-63times
Harmonic content 0-40%
Harmonic phase 0-359.99
Harmonic setting accuracy (10%±0.1%)RD(2)
Power energy measurement error
Active power energy 0.02%RG or 0.05%RG
Reactive power energy 0.05%RG or 0.1%RG
Power pulse output
Power pulse type Active pulse, reactive pulse
Active power pulse output 5V, 10mA
Power pulse input
Energy pulse type Support active and reactive pulse, the highest frequency power pulse input is 200K.
Standard
Standard IEC62053-21,22,23; IEC60736; ANSI C12.20-2002;
JJG 597-2005; JJG596-2012; JJG 1085-2013; JJF 68-2019;
DL/T 826-2002; DL/T 1478-2015; DL/T 448-2016
Safety
Isolation protection IEC61010-1:2001
Measurement category 300V CAT III, 600V CAT II
Degree of protection IP20
Declaration of conformity CE & CNAS certified
Functions
LCD 7 inch touch TFT color LCD
Communication port RS232 or USB
Programmable Yes
Meter position 1pc or 3pcs
PC control software Optional
Mechanical parameters
Dimensions (W×D×H)(mm) 455 x 440 x 150
Weight (kg) 12
Environmental conditions
Ambient temperature -10°C to +40°C
Relative humidity 35%-85%
(1) RG means range, the same as below;
(2) RD means the setted harmonic content, harmonic can be a single output, also multiple output.
GF102 Portable Single Phase Energy Meter TesterGF102 Portable Single Phase Energy Meter TesterGF102 Portable Single Phase Energy Meter TesterGF102 Portable Single Phase Energy Meter TesterGF102 Portable Single Phase Energy Meter Tester

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More