Ratio & Phase Error Orrable High Precision CT PT Analyzer with Printer

After-sales Service: 24 Hour Service
Warranty: 3 Years
Application: CT Analyzer
Power: Electricity
Certification: FDA, CE, IAF, CCC, Ilac.Mra
Voltage Output: 100V
Samples:
US$ 30000/Set 1 Set(Min.Order)
| Request Sample
Customization:
Gold Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
GF1061
Current Output
5A
LCD Display
With LCD Display
Customized
Non-Customized
Key Word
Currnet Transformer Tester
Accuracy
0.02%, 0.05%, 0.1%
LCD
7 Inch Touch LCD
CT Ratio
1-50000
PT Ratio
1-30000
Auto Test
Yes
Communication
USB, RS232, Bt
Weight
4.5kg
Transport Package
Standard Carton Box
Specification
GF1061 0.05%
Trademark
GFUVE
Origin
Beijing China
HS Code
90308490
Production Capacity
500 Sets/Month

Product Description

GF1061PORRABLE HIGH PRECISION CT PT ANALYZER WITH PRINTER

GF1061 portable CT PT analyzer is mainly used for field or lab testing, it can finish the measurements (M) and protection (P) class CT, PT and TYP class CT. Adopt 7 inch touch TFT LCD, self-equipped mini type printer supporting field printing; supporting to use USB flash disk to download data or RS232 port to PC control. This model GF1061 CT PT Analyzer is the most complete and easy-to-use testing system for protection and metering CTs according to IEEE C57.13 and IEC60044 & IEC61869 standards.
Ratio & Phase Error Orrable High Precision CT PT Analyzer with PrinterRatio & Phase Error Orrable High Precision CT PT Analyzer with Printer

APPLICATION

Metrological service center;

Electricity power bureau & power company;

National Metrology and testing department;

Power engineering commissioning company;

Current transformer and voltage transformer factory;

Power plant;

Electrical laboratory;

Electrical Department of industrial and mining enterprises;
 

FEATURES

Full automatic demagnetization;

Download word/PDF test report;

10% error curve, 5% error curve;

Testing of various types of CT/PT;

Easy to operate, test error quickly;

Test CT all parameter in one minute;

Auto check knee point voltage value;

CT excitation curve;

Data storage 10000groups;

7 inch color touch TFT LCD;

With battery function optional;

The best light CT analyzer-only 4.5KG;

Programmable control by PC computer;

Knee point voltage from 0.1 V up to 50 kV;

 

MAIN FUNCTIONS

I. Current Transformer (CT) II. Voltage Transformer (PT)
1. Magnetization curve 1. Excitation characteristic test
2. Transformation ratio test 2.  Transformation ratio test
3. Polarity 3.  Polarity
4. 5% and 10% error curve 4.  Ratio error, phase error
5. Accuracy limiting factor (ALF) 5.  Degauss
6. Degauss 6.  Calculation of knee point value
7. Ratio error, phase error 7. Burden test
8. Automatic calculation of excitation knee point value 8. Resistance test(Winding DC resistance test)
9. Burden test
10. Resistance test(Winding DC resistance test)
11. Secondary time constant (Ts)
12. Remanence coefficient (Kr)
13. Transient dimensioning factor (Ktd)
14. Peak instantaneous error (Er)
15. Magnetizing inductance (LU)
16. Instruments security factor(FS)
17. Composite error
18. Visible Flashing LED when terminals are Live
19. Audible Warning Sound Error Indicator
20. Ability to Store and Generate/Print Report of Tests
21. Built-in Thermal Printer

PARAMETERS

Electrical parameters
Accuracy 0.02% or 0.05%
Power Supply AC 220V±10% or AC 120V±10%, 50/60Hz or Battery
Output voltage 0-100Vrms
Output current 0-5Arms (20A peak-value)
Output power 0-400 VA (1500 VApeak)
Automatic frequency variation range 0.1-60Hz
Equivalent excitation voltage ≤5000V/50KV
Accuracy ≤0.02% or 0.05%
Secondary winding DC resistance measurement
Range0.1-1000Ω
Accuracy≤0.02% or 0.05%
Secondary actual load measurement
Range0.1VA-1000VA
Accuracy≤0.02%±0.1VA
CT/PT phase error measurement
Accuracy±1min (typical) / 3 min (guaranteed)
Resolution0.1min
CT ratio error measurement
Range1-50000
Accuracy≤0.02% or 0.05%
PT ratio error measurement
Range1-30000
Accuracy≤0.02% or 0.05%
LCD display 7' inch TFT touch color LCD
Cable Length Primary 5m; Secondary 5m; others customized
Communication port USB, RS232, WIFI
PC control software Yes, Optional
Printer Yes, Thermal printer
Standards
Reference standards GB1207-2006, GB1208-2006, GB16847-1997
IEC60044-1, IEC60044-2,6, IEC61869, ANSI/IEEE C57.13
Safety standards GB 4793.1-2007
EMC EMC standard 89/336/EEC
FCC Subpart B of Part 15 Class A
IEC 1000-4-2/3/4/6
Mechanical parameters
Overall dimension (L x W x H) (mm) 280 x 250 x 160
Weight (kg) ≤4.5
Environmental conditions
Relative humidity Relative humidity 5%-95% not condensing
Operating temperature -10°C to +50°C
Storage temperature -20°C to +70°C
Altitude ≤1000m; If the altitude is greater than 2500m, the instrument needs to be customized