FU2200A Mini RS485 digital power meter
Introduction
The FU2200A three phase digital Multifunction ethernet Power Meter with Data Logger is a range of economical yet highly functional three-phase multifunction power and energy meters manufactured by GFUVE. These meters provide excellent value for monitoring power and energy management systems. The 2200A three phase digital Multifunction ethernet Power Meter with Data Logger may be used as data gathering devices for intelligent power distribution or plant automation systems. All monitored data is available via a standard digital RS485 communication port running the Modbus RTU protocol. With a wide range of models to choose from, the 2200A three phase digital Multifunction ethernet Power Meter with Data Logger offers unparalleled value and functionality.
Features
· True-RMS measuring Parameters.
· ANSI and IEC 0.5 Accuracy class.
· Power Quality Analysis.
· 4 Quadrant Energy;
· 4MB onboard memory;
· Data logging
· High-speed RS485, Ethernet Port (optional);
· Measure Individual Harmonics from 2nd to 63th (optional);
· Module Design;
· TOU, 4 Tariffs, 12 Seasons, 14 Schedules
· Class leading Warranty.
· With management software
Applications
· Metering of distribution feeders, transformers, generators, capacitor banks and motors.
· Medium and low voltage systems.
· Commercial, industrial, utility.
· Power quality analysis.
Measurement Parameters
Voltage (Ph-N); Voltage (Ph-Ph); Current; Frequency; PF; Active Power(W); Reactive Power(Q); Apparent Power(S), 2~63th harmonics(optional)
Computation
Forward active power energy
Reverse active power energy
Forward active power energy
Reverse reactive power energy
Maximum Demand
Ia, Ib, Ic, Σ Ptotal, Σ Qtotal, Σ Stotal, 15 minutes
Display
Wide screen angle, Light blue back-lit LCD Display, 5 Displays figures. 4 operation keys.
Memory
Standard 2M memory, extended to 4M;
It can be set arbitrarily store data from 1minute to 60minutes intervals, Standard factory 15minutes in one group data recorder.
It can recorder not less than 4 channel (voltage, current, power, power factor and so on) and four (Forward active power energy, Reverse active power energy, Forward active power energy, Reverse reactive power energy), recording 1 times every 15 minutes, at least 1 years of data, through the communication port to read; You can select data items what you need to be stored through software;
Communication
RS-485 interface port support, 32 (128) Networking, ModBus-RTU communication protocol.
Connection Mode
3P4W, 3P4W BAL, 3P3W, 3P3W BAL;
Programmable
Measuring System: 3P4W/3P3W etc.
Transformation Ratio: PT 1~10000; CT 1~10000.
Communication
RS485, Baud: 1200~57600, Standard 38400; Ethernet Port (optional)
Dimension
Mounting Panel: 96 X 96mm
Mounting
Panel Mounting
Trepanning: 92 X 92mm
Power Supply (AC/DC)
AC85~400V / DC85~330V,
Power Consumption: <4VA
Working condition
Temperature: -25 ~ 55 ° C
Humidity: 20% ~ 95%RH, Without condensation
Warranty
Three years warranty
Voltage |
0.2% |
0.01V |
0.5~500kV |
Current |
0.2% |
0.01mA |
5mA~50000A |
Active Power |
0.5% |
0.2W |
-9999MW~+9999MW |
Reactive Power |
2% |
0.2var |
-9999Mvar~+9999Mvar |
ApparentPower |
0.5% |
0.2VA |
0~9999MVA |
Active Power Demand |
0.5% |
0.2W |
-9999MW~+9999MW |
Reactive Power Demand |
2% |
0.2var |
-9999Mvar~+9999Mvar |
Apparent Power Demand |
0.5% |
0.2VA |
0~9999MVA |
Power Factor |
0.005 |
0.0001 |
-1.0000~0~1.0000 |
Frequency |
0.01Hz |
0.01Hz |
45.000~65.000Hz |
Energy |
Primary |
0.5% |
0.1kWh |
0~99999999.9kWh |
Secondary |
0.001kWh |
0~999999.999kWh |
Reactive Energy |
Primary |
2% |
0.1kvarh |
0~99999999.9kvarh |
Secondary |
0.001kvarh |
0~999999.999kvarh |
Apparent Energy |
Primary |
0.5% |
0.1VAh |
0~99999999.9kVAh |
Secondary |
0.001VAh |
0~999999.999kVAh |
Phase Angle |
0.1° |
0.01° |
0~359.99° |
Unbalance Factor |
2% |
0.01% |
0~300.00% |
PT |
|
1 |
1~10000 |
CT |
|
1 |
1~10000 |
Addr |
|
1 |
1~254 |
|
Parameter |
Accuracy |
Resolution |
Range |