| Customization: | Available |
|---|---|
| Type: | Electromagnetic |
| Output Signal Type: | Analog Output |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
| Name: | Split Core Current Transformer | Application: | Energy Meter |
| Usage: | Current Measurement | Theory: | Electromagnetic Induction |
| Material: | Epoxy Resin And Supercrystalline Alloy | Ratio: | 100-1000A/5A Or 1A |
| Accuracy: | 0.5% | Burden: | 2.5-10VA |
| Diameter: | 50mm | Color: | Red & Black |
| Technical parameters | |
| Standards | IEC60044-1; IEC 61869-2; NTC 2205; GB1208-2006; ANSI C57.13 |
| Accuracy Class | 0.5S, 0.5%, 1%, 3% |
| Range of primary rated current | 100-1500A |
| Range of Rated load | ≤10VA |
| Rated frequency | 50/60Hz |
| Rated secondary current | 5A or 1A |
| Rated short-time thermal current | 40kA, 1S |
| Rated continuous thermal current | 150%I1n |
| Secondary winding power frequency withstand voltage | 3kV, 1min |
| Safety Factor Rating | (FS) <10 |
| Output signal | 1A, 5A, 333mV, 1V or 5V(customized) |
| Cable length | 2.5m, 5m, 10m(customized) |
| Flame retardant ABS plastic shell inside, jaw waterproof apron. | |
| Mechanical parameters | |
| Aperture (mm) | Φ55 |
| Dimensions (W×D×H) (mm) | 180×138×52 |
| Weight (kg) | 2 |
| Working conditions | |
| Operating temperature | -35°C to +65°C, not exceeding +40°C |
| Storage temperature | -40°C to +70°C |
| Ingress Protection | IP65 |
| Environment | outdoors or indoors |
| The Height of above sea level | 0- 3000m |
| Conditions | No existence of severely begrimed, erosive and radioactive gas in the air. Continuous working under the rated current is allowed. |
| Technical parameters | |
| Standards | IEC60044-1; IEC 61869-2; ANSI C57.13; NTC 2205; GB1208-2006 |
| Rated primary current | 30-600A |
| Rated load | ≤10VA |
| Rated frequency | 50Hz or 60Hz |
| Rated secondary current | 5A or 1A |
| Rated short-time thermal current | 40kA, 1S |
| Rated continuous thermal current | 120%I1n |
| Secondary winding power-frequency voltage | 3kV, 1min |
| Instrument security factor | FS≤10 |
| Mechanical parameters | |
| Dimensions (W×D×H) (mm) | φ50xφ110x52 |
| Weight (kg) | 1.6 |
| Operating conditions | |
| Operating temperature | -35°C to +55°C |
| Daily average temp | <+40°C |
| Altitude | <3500 meters |
| Condition | No existence of severely begrimed, erosive and radioactive gas in the air. Permission of long-term operation under rated current. |
| Type | LZCK322-10 | LZCK322-10 | ||||
| Purpose | Measuring current transformer | Protection current transformer | ||||
| Ratio | Accuracy class and rated load(VA) | Accuracy class and rated load(VA) | ||||
| I1/I2 | 0.5 | 1 | 3 | 10P15 | 10P10 | 10P5 |
| 30/1 | 1 | 1.5 | ||||
| 50/1 | 1 | 2 | 1.25 | |||
| 75/1 | 1.5 | 2.5 | 1 | 2 | ||
| 100/1 | 2 | 2.5 | 3 | 1.5 | 2.5 | |
| 200/1 | 2.5 | 1.25 | 2.5 | |||
| 300/1 | 3.75 | 1.25 | 2.5 | |||
| 400/1 | 7.5 | 1.25 | 2.5 | |||
| 500/1 | 10 | 1.25 | 3 | |||
| 600/1 | 10 | 1.5 | 3 | |||
| 50/5 | 2.5 | |||||
| 75/5 | 2.5 | |||||
| 100/5 | 2.5 | |||||
| 200/5 | 3.75 | |||||
| 300/5 | 5 | |||||
| 400/5 | 7.5 | 2.5 | ||||
| 500/5 | 7.5 | 2.5 | ||||
| 600/5 | 10 | 3.75 | ||||
| Model | Primary rated current | Rated load | Aperture (mm) | Description (mm) | Weight (kg) | Material | Water-proof |
| LZCK-55 | 100-1500A | ≤10VA | φ55 | 180×138×52 | 2 | PC | IP65 |
| LMCK185-10 | 300-3000A | ≤25VA | φ185 | 350×283×55 | 4.5 | PC | IP65 |
| LZCK310-10 | 300-600A | ≤10VA | φ50 | φ50 x φ110 x 32 | 1 | Resin | silicon case (option) |
| LZCK322-10 | 30-600A | ≤10VA | φ50 | φ50 x φ110 x 52 | 1.6 | Resin | silicon case (option) |
| LZCK350-10 | 20-600A | ≤25VA | φ50 | φ50 x φ110 x 105 | 3.1 | Resin | silicon case (option) |
| LZCG530-10 | 30-600A | ≤20VA | φ45 | φ45 x φ120 x 65 | 2.1 | Resin | silicon case (option) |