| Customization: | Available |
|---|---|
| Warranty: | Three Years |
| Application: | Electromagnetic Instrument |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
| Electrical parameters | |
|---|---|
| Accuracy class | 0.02%, 0.05% |
| Power supply | AC 220 V±10% or 110 V±10%, 50/60Hz |
| Power consumption | <30VA |
| Warming-up time | <30min |
| Voltage measurement | |
| U1, U2,U3 | 6.25V, 12.5V, 25V, 50V, 100V, 200V, 400V, 800V (switch automatically), max 1000V |
| Range | (0-120%)RG |
| Resolution | 0.01%RG |
| Accuracy | 0.02%RD or 0.05%RD |
| Current measurement | |
| I1, I2, I3 | 0.25, 0.5, 1, 2.5, 5, 10, 25, 50, 100A(switch automatically) |
| Range | (0-120%)RG |
| Resolution | 0.01%RG |
| Accuracy | 0.02%RD or 0.05%RD |
| Power measurement | |
| Active accuracy | 0.02%RD or 0.05%RD |
| Reactive accuracy | 0.05%RD or 0.1%RD |
| Apparent accuracy | 0.02%RD or 0.05%RD |
| Energy measurement | |
| Active accuracy | 0.02%RD or 0.05%RD |
| Reactive accuracy | 0.05%RD or 0.1%RD |
| Phase measurement | |
| Range | 0.00°-359.99° |
| Resolution | 0.001° |
| Accuracy | 0.02° (voltage ≥50V and current ≥250mA) |
| Frequency measurement | |
| Range | 45-65Hz |
| Resolution | 0. 001Hz |
| Accuracy | 0.002Hz |
| Power Factor measurement | |
| Range | -1.0 ~ 0 ~ +1.0 |
| Resolution | 0.0001 |
| Accuracy | 0.0005 |
| Electric energy pulse output | |
| Pulse constant range | 1-2880000000 |
| Output frequency of max. pulse | 600 kHz |
| Load capacity | >2mA |
| Default pulse output frequency | 10kHz-600kHz |
| Energy pulse Input | |
| Input range of pulse constant | 600-700000 |
| Setting range of test pulse | 1-999999999 |
| Max. pulse receiving frequency | 2MHz |
| Pulse input level | 5V |
| Voltage/current harmonics measurement | |
| Times | 2-31 |
| Error | 0.05% |
| Distortion degree error | 0.05% |
| Transducer measurement | |
| DC voltage range | ±1, ±5, ±10, ±20 V |
| Accuracy | 0.01% |
| DC current range | ±1, ±2.5, ±5, ±10, ±20mA |
| Accuracy | 0.01% |
| Ripple error | 1% |
| DC measurements (option) | |
| DC voltage | 50V, 100V, 200V, 400V, 800V (switch automatically), max 1000V |
| Range | (0 -120%) RG |
| Resolution | 0.01% RG |
| Accuracy | 0.02% RD |
| DC current | 0.1A, 0.3A, 1A, 3A, 10A, 30 A(switch automatically) |
| Range | (0-120%) RG |
| Resolution | 0.01% RG |
| Accuracy | 0.02% RD |
| Mechanical parameters | |
| Dimensions (W×H×D) (mm) | 440×360×160 |
| Weight (kg) | 10 |
| Environmental conditions | |
| Operating temperature | 10°C to 30°C |
| Relative humidity | ≤85% |