• GF6019d 1000V 100A 0.05% High Precision DC Energy Meter Test Equipment
  • GF6019d 1000V 100A 0.05% High Precision DC Energy Meter Test Equipment
  • GF6019d 1000V 100A 0.05% High Precision DC Energy Meter Test Equipment
  • GF6019d 1000V 100A 0.05% High Precision DC Energy Meter Test Equipment
  • GF6019d 1000V 100A 0.05% High Precision DC Energy Meter Test Equipment
  • GF6019d 1000V 100A 0.05% High Precision DC Energy Meter Test Equipment

GF6019d 1000V 100A 0.05% High Precision DC Energy Meter Test Equipment

After-sales Service: 24 Hour Service
Warranty: 3 Years
Application: DC Energy Meter Test Equipment
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
GF6019d 1000V 100A 0.05% High Precision DC Energy Meter Test Equipment pictures & photos
GF6019d 1000V 100A 0.05% High Precision DC Energy Meter Test Equipment
US $30,000 / Set
Min. Order: 1 Set
Gold Member Since 2013

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory

Basic Info.

Model NO.
GF6019D
Power
Electricity
Certification
FDA, CE, IAF, CCC, Ilac.Mra
Voltage Output
1000V
Current Output
100A
Thermocouple (TC)
None
Resistance-Temperature Detector (RTD)
None
LCD Display
With LCD Display
Customized
Customized
Keyword
High Precision DC Energy Meter Test Equipment
Acuuracy
0.05%, 0.1%
Weight
12kg
LCD
Touch TFT Color LCD
Auto Test
Yes
Optical Sensor
Yes
Energy Pulse Input & Output
Yes
Programmable
Yes
Transport Package
Standard Wooden Case
Specification
Dimensions (W× D× H) (mm) 495x390x195
Trademark
GFUVE
Origin
China
Production Capacity
1000 Sets/Year

Packaging & Delivery

Package Size
80.00cm * 80.00cm * 50.00cm
Package Gross Weight
45.000kg

Product Description

GF6019D 1000V 100A 0.05% HIGH PRECISION DC ENERGY METER TEST EQUIPMENT

The GF6019D high precision DC energy meter test equipment consists of an DC voltage standard source, DC current standard source and DC power source. (up to 1150V/600A) and built-in DC electronic reference standard of accuracy class 0.05%. Characteristic features of the GF6019D are its wide measuring range, high accuracy and high tolerance to unwanted external influences. The equipment offers high functionality combined with an excellent menu guided operation via built-in keyboards and colored 8" LCD-display. It can test DC energy meter basic error, starting test, creep test, error of time of day.

GF6019d 1000V 100A 0.05% High Precision DC Energy Meter Test Equipment

FEATURES

  • 0-100A/0-1150V;

    8 inch TFT touch screen;

    DC power source integrated;

    Test by automatic or manual;

    Accuracy class 0.05 or 0.02;

    Start testing and creep testing;

    Recorder 10000 sets energy meter data;

    Overload, short circuit, open circuit protection;

PARAMETERS

Electrical parameters
Accuracy 0.05%; 0.02%
Power Supply One Phase AC 180-265V or 85-150V, frequency 50/60Hz.
DC Voltage Output
Range 100V, 350V, 500V, 700V (max 800V);
65V, 250V, 500V, 750V, 1000V (max 1150V)
Adjustment range (0-120)%RG(1)
Adjustment fineness 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional.
Stability 0.01%/120s
Distortion 0.1% (Non-capacitive load)
Output load 20VA or 50VA
Full load regulation rate ≤±0.01%RG
Accuracy ±(0.03%RD+0.02%RG)
DC Current Output
Range 75mV, 2A, 20A, 50A, 100A;
0.001A, 0.005A, 0.02A, 0.05A, 0.2A, 1A, 3A, 10A, 20A, 50A, 100A, 500A (max 600A)
small signal 2.5mV, 20mV, 100mV, 1V, 5V
Adjustment range (0-120)%RG
Adjustment fineness 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional.
Stability <0.01%/120s
Distortion ≤0.1% (Non-capacitive load)
Output load 150VA or 1200VA
Full load regulation rate ≤±0.01%RG
Accuracy ±(0.03%RD+0.02%RG)
Externally attached shunt 100mV
Accuracy ±(0.06%RD+0.04%RG)
DC Power Output
power output stability <0.01%RG/120s
power accuracy ±(0.03%RD+0.02%RG)
DC Power Energy Measurement Error
power energy ±(0.03%RD+0.02%RG)
Power Pulse Output
Power Pulse Output 20KHz (Full-Range)
Power Pulse Input
Energy pulse input 20KHz
Ripple output 20-500Hz ripple output
Communication port USB port, RS232, 10/100M LAN
Mechanical parameters
Dimensions (W×D×H) (mm) 460x460x175; 630x600x450
Weight (kg) 22kg, 55kg
Environmental conditions
Ambient temperature -10°C to +40°C
Relative humidity 35%-85%
(1) RG means range, the same as below;
(2) RD means the setted harmonic content, harmonic can be a single output, also multiple output.
GF6019d 1000V 100A 0.05% High Precision DC Energy Meter Test EquipmentGF6019d 1000V 100A 0.05% High Precision DC Energy Meter Test EquipmentGF6019d 1000V 100A 0.05% High Precision DC Energy Meter Test EquipmentGF6019d 1000V 100A 0.05% High Precision DC Energy Meter Test Equipment

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
GF6019d 1000V 100A 0.05% High Precision DC Energy Meter Test Equipment pictures & photos
GF6019d 1000V 100A 0.05% High Precision DC Energy Meter Test Equipment
US $30,000 / Set
Min. Order: 1 Set
Gold Member Since 2013

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
Registered Capital
5000000 RMB
Plant Area
>2000 square meters