Customization: | Available |
---|---|
Type: | Electromagnetic |
Output Signal Type: | Digital Output |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
The S120 clamp on ct is well suited for power quality applications where high accuracy and low phase shift along with wide frequency from 10Hz to 2MHz are important. Measurement range is 100mA to 3000A.
The S120 clamp on current transformer is a general purpose 3000A AC clamp current probe transformer designed for use with DMMs & BNC, cable fault analysis and loggers instruments that have a current input. It has a 1000:1 or 2000:1 ratio and output of 1mA per amp or 1mV per amp measured in the jaw. The S120 has an integral 2.5m or 5m lead terminated. The rounded jaw design on this clamp probe makes it well-suited for cable fault analysis applications where high accuracy and low phase shift and wide frequency.
UL, CE CNAS mark;
Frequency 10-2MHz;
Holding wire diameter: φ120mm;
Conforms to EN 61010, 600V CAT III;
Low phase shift for power measurement;
Industrial design & beautiful appearance;
High content nickel metal permalloy core;
Measurement range of 1mA to 3000A AC;
Transformation ratio: 1000:1, 2000:5, 3000:5;
Improved ergonomic design & easy operation;
High precision 0.1% for current measurement;
Designed for DMMs, recorders, loggers, oscilloscopes, power and harmonic meters;
Ratio | 1000:1, 2000:5 or 3000:5 (customized) |
Accuracy class | 0.1%, 0.2%, 0.5% |
Primary current | 0-3000A AC |
Secondary current | 0-1A or 0-5A AC (customized) |
Secondary voltage | 0-2V, 0-5V AC (customized) |
Max. Cont. Input current | 3600A |
Load capacity | ≤20Ω, standard 4Ω |
Over voltage category | CAT III 600V |
Output signal (AC current) | 500mA, 1A, 2A, 5A AC at nominal input current |
Output signal (AC voltage) | 1V, 2V, 5V, 10V AC at nominal input current |
Frequency range | 10Hz-2MHz |
Dielectric strength | 3KV 50Hz/60Hz at 1 minute |
Temperature range | -40°C to +55°C |
Output | 2.5 meter cable with D01 connector or BNC |
Max. voltage not insulated conductors | 600V |
Standard | EN 61010-1, EN 61010-2-032, EN 61010-2-031 IEC60044-1, & IEC61869-2, 600V CAT III |
Installation | clamp type |
Output mode | lead output(2.5m, 5m or 10m) |
Connector | BNC, 4mm banana, signal cable (2 cores), customized |
Range version | 100A, 200A, 400A, 500A, 1000A, 2000A, 3000A |