GF302D Portable Three Phase Kwh Meter Test Analyzer

Product Details
Customization: Available
After-sales Service: Yes
Warranty: 3 Years
Secured Trading Service
Diamond Member Since 2013

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Address
Bldg. 2-1111, Joy Mansion, No. 99 Chaoyang North Road, Chaoyang District, Beijing, China
International Commercial Terms(Incoterms)
FOB, CIF, FCA, EXW
Terms of Payment
LC, T/T, PayPal, Western Union
  • GF302D Portable Three Phase Kwh Meter Test Analyzer
  • GF302D Portable Three Phase Kwh Meter Test Analyzer
  • GF302D Portable Three Phase Kwh Meter Test Analyzer
  • GF302D Portable Three Phase Kwh Meter Test Analyzer
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
Overview

Basic Info.

Accuracy
0.5%
Current Output (AC)
5V, 10mA
Capacity
5kVA
Range
0-1100A
Resolution
0.1A
with Timer
0.0001 to 999.999s
Standard
IEC 62053-21,22,23; IEC60736; ANSI C12.20-2002;
Communication Port
RS232
Weight(Kg)
22kg
Cable
Length 2X6m, 70mm²
Current Duration
1000A 2-3minutes
Continuous Output
400A
Operating Temperature
-10°C to 50°C
Storage Temperature
-10°C to +40°C
The Current Output Waveform Distortion
≤5%
Transport Package
Plywood Box
Specification
500 × 600 × 175mm
Trademark
GFUVE
Origin
China
HS Code
903033
Production Capacity
5000sets/Year

Product Description

Product Description

GF302DPORTABLE THREE PHASE KWH METER TEST EQUIPMENT

The GF302D portable meter test equipment is used for grid corporation of measurement and energy test center, management department of power supply bureau, national energy measurement of testing authorities, and also used to test each kind of single/three phase kWh meter of industries and mining enterprises as well as electric meter manufacturers. Meanwhile, the meter test equipment also can be used as one high precision standard power source, voltage source and current source. Portable design, used in the laboratory or on site to auto check energy meter error.

Detailed Photos

GF302D Portable Three Phase Kwh Meter Test AnalyzerGF302D Portable Three Phase Kwh Meter Test Analyzer

Product Parameters

PARAMETERS

Electrical parameters
Accuracy 0.05%, 0.1%
Power supply One phase AC 85-265V, frequency 50/60Hz.
AC voltage output
Range (U1, U2, U3) 57.7V, 100V, 220V, 380V; Max 500V
or 69.3V, 120V, 240V, 480V (optional); Max 600V
Adjustment range (0-120)%RG(1)
Adjustment fineness 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional.
Stability 0.01%/120s
Distortion 0.3% (Non-capacitive load)
Output load each phase 25VA, 50VA, 100VA
Measuring accuracy 0.05%RG or 0.02%RG
AC current output
Range (I1, I2, I3) 200mA, 1A, 5A, 20A, 100A; Max 120A
Adjustment range (0-120)%RG
Adjustment fineness 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional.
Stability <0.01%/120s
Distortion ≤0.3% (Non-capacitive load)
Output load 50VA or 100VA
Accuracy 0.05%RG or 0.02%RG
Power output
Active power output stability <0.01%RG/120s
Reactive power output stability <0.02%RG/120s
Active power measuring accuracy 0.05%RG
Reactive power measuring accuracy 0.1%RG
Apparent power measuring accuracy 0.05%RG
Phase output
Output adjustment range 0°-359.999°
Output adjustment fineness 10, 1, 0.1, 0.01 as optional.
Resolution 0.01°
Accuracy 0.02° or 0.05°
Power factor
Adjustment range -1 ~ 0 ~ 1
Resolution 0.0001
Measurement accuracy 0.0005
Frequency output
Adjustment range 40Hz-70Hz
Output adjustment fineness 5Hz, 1Hz, 0.1Hz, 0.01Hz as optional.
Resolution 0.001Hz
Accuracy 0.002Hz
Voltage/current/harmonic setting
Harmonic number 2-51times or 2-63times
Harmonic content 0-40%
Harmonic phase 0-359.99
Harmonic setting accuracy (10%±0.1%)RD(2)
Power energy measurement error
Active power energy 0.05%RG
Reactive power energy 0.1%RG
Power pulse output
Power pulse type Active pulse, reactive pulse
Active power pulse output 5V, 10mA
Power pulse input
Energy pulse type Support active and reactive pulse, the highest frequency power pulse input is 180K.
Communication port
Communication port RS232
Standard
Standard IEC 62053-21,22,23; IEC60736; ANSI C12.20-2002;
JJG 597-2005; JJG596-2012; JJG 1085-2013; JJF 68-2019;
DL/T 826-2002; DL/T 1478-2015; DL/T 448-2016
Safety
Isolation protection IEC 61010-1:2001
Measurement category 300V CAT III, 600V CAT II
Degree of protection IP20
Declaration of conformity CE certified
Mechanical parameters
Dimensions (W×D×H)(mm) 500 × 600 × 175
Weight (kg) 22
Environmental conditions
Ambient temperature -10°C to +40°C
Relative humidity 35%-85%
(1) RG means range, the same as below;
(2) RD means the setted harmonic content, harmonic can be a single output, also multiple output.

SELECTION GUIDE

NO. Accuracy Voltage range Current range Weight
302D12001 0.1% 0-600V 0-120A 22KG
302D12005 0.05% 0-600V 0-120A 22KG
302D2401 0.1% 0-600V 0-24A 16KG
302D2405 0.05% 0-600V 0-24A 16KG
302D1201 0.1% 0-500V 0-12A 15KG
302D1205 0.05% 0-500V 0-12A 15KG
302D601 0.1% 0-380V 0-6A 12KG
302D605 0.05% 0-380V 0-6A 12KG