• 100 5 Split Core Current Transformer Ct′s for Metering
  • 100 5 Split Core Current Transformer Ct′s for Metering
  • 100 5 Split Core Current Transformer Ct′s for Metering
  • 100 5 Split Core Current Transformer Ct′s for Metering
  • 100 5 Split Core Current Transformer Ct′s for Metering
  • 100 5 Split Core Current Transformer Ct′s for Metering

100 5 Split Core Current Transformer Ct′s for Metering

Application: Electronic, Instrument, Position Sensor
Type: Current Transformer
Phase: Single
Operation Condition: Indoor
Usage: Protection, Measurement
Winding Form: Single Layer & Tightly Wound Type
Customization:
Gold Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
FU-16
Insulating Medium
Epoxy Resin
Installation
Active Type
Magnetic Circuit Structure
Single Stage Type
Voltage Transformation Principle
Electromagnetic Type
Ratio
1000: 1 or 2000:1 , Customized
Key Words
Current Transformers for Metering
Key Word
DBP 100 5 Split Ct′s
Model
DBP Split Core Current Transformer
Rated Voltage
720V
Accuracy Class
0.2%, 0.5 %, 1%
Rated Primary Current
20 a/30A/40A/50A/60A/80A/100A/150A/200A
Output Signal
10mA-200mA Acoptional 333mv AC or 100mv-2V Optonal
Frequency Range
40 Hz-500 Hz
Max. Jaw Opening
16 mm
Transport Package
Standard Export Box
Specification
38mm x 55mm x 18 mm
Trademark
GFUVE
Origin
Beijing, China
Production Capacity
200pieces/Day

Product Description

product description
100 5 Split Core Current Transformer Ct′s for Metering

FU-16 series of split-core current transformer offers 333mV, 100mV-2V and 10mA-200mA at secondary from
sensed primary current. Without using secondary CT inside of meter, users directly connect FU-16 series to
meter for high accuracy metering application. It enables one meter to be adopted for various current rating by only changing primary CT so it makes compact meter design and reduces developing cost. Also, over-voltage protection circuit is included to offer safe, fast and cost effective installation.
Features
1. Most cost-effective
2. Faster installation
3. Safe and easy installations
4. High accuracy 0.5
5. Holding wire diameter: φ16mm
6. Measurement range of 1mA to 200A AC
7. Low phase shift for power measurement
8. Output model: Lead output(2.5m)
9. Isolated plastic case recognized according to UL94-V0
10. Small-size, compact size, light-weight
11. Over-Voltage protection circuit is installed.
12. UL / EN 61010 - 1 certified
Applications
1. Power meter and harmonic meters
2. Energy meter (kWh meter)
3. Recorders, loggers, oscilloscopes
4. Power quality monitoring
5. Switchgear
6. Distributed measurement systems
7. General Sets
8. Control panels
Technical parameters  
Standards IEC/EN60044-1 & IEC61010-1 & IEC61869-2&ANSI C57.13
Ratio 1000: 1 or 2000:1 , customized
Nominal input current(Primary current) 20A/30A/40A/50A/60A/80A/100A/150A/200A
Overload withstand 1.2 times rated current continuously
Accuracy 0.2%, 0.5 %, 1%
System Voltage 720V(0.72kV)
Output signal 10mA-200mA AC optional
333mV AC or 100mV-2V optional
Frequency range 40 Hz-500 Hz
Dielectric strength 3KV 50Hz/60Hz at 1 minute
Output Standard 2.5 meter cable
Protection Level 3.0V0-P
Installation Category CATII or CATIII 600VAC
Max. jaw opening 16 mm
Mechanical parameters
Dimensions (W×D×H) (mm) 38mm×55mm×18mm
Weight(g) 60
Operating conditions
Operating temperature -25°C to +55°C
Relative Humidity 0-85% non-condensing
Altitude <3500 meters
Condition No existence of severely begrimed, erosive and 
radioactive gas in the air. Permission of long-term 
operation under rated current.
Ordering information
Be sure to the type, current ratio, accuracy class, rated load and use of the products when you plan to make a order. Special specifications could be customized. All kinds of different specifications and parameters current transformers can be made according to your needs.