| Customization: | Available |
|---|---|
| After-sales Service: | Technical Support & After-Sales Service |
| Warranty: | 36 Months |
| Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
|---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency







Electrical parameters | |
Accuracy | 0.02%, 0.05%, 0.1% |
Power supply | One Phase AC 100-265V, frequency 50/60Hz. |
AC voltage output | |
Range (U1, U2, U3) | 0-600V; 0-500V; 0-380V; 0-300V; |
Adjustment range | (0-120)%RG(1) |
Adjustment fineness | 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional. |
Stability | 0.01%/120s |
Distortion | 0.3% (Non-capacitive load) |
Output load | Each phase 25VA |
Accuracy | 0.02%RG or 0.05%RG |
AC current output | |
Range (I1, I2, I3) | 0-6A; 0-12A; 0-20A; 0-50A; 0-120A; |
Adjustment range | (0-100)%RG |
Adjustment fineness | 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional. |
Stability | <0.01%/120s |
Distortion | ≤0.3% (Non-capacitive load) |
Max output load | 20VA or 50VA or 100VA; |
Accuracy | 0.02%RG or 0.05%RG |
Power measurement | |
Active power output stability | <0.01%RG/120s |
Reactive power output stability | <0.02%RG/120s |
Active power measuring accuracy | 0.02%RG or 0.05%RG |
Reactive power measuring accuracy | 0.05%RG or 0.1%RG |
Phase output | |
Output adjustment range | 0°-359.999° |
Output adjustment fineness | 10, 1, 0.1, 0.01 as optional. |
Resolution | 0.01° |
Accuracy | 0.015° |
Power factor | |
Adjustment range | -1 ~ 0 ~ 1 |
Resolution | 0.0001 |
Measurement accuracy | 0.0005 |
Frequency measurement | |
Range | 40Hz-70Hz |
Resolution | 0.001Hz |
Accuracy | 0.002Hz |
Voltage/current/harmonic setting | |
Harmonic number | 2-63times |
Harmonic content | 0-40% |
Harmonic phase | 0-359.99 |
Harmonic setting accuracy | (10%±0.1%)RD(2) |
Power energy measurement error | |
Active power energy | 0.02%RG or 0.05%RG |
Reactive power energy | 0.05%RG or 0.1%RG |
Power pulse output | |
Power pulse type | Active pulse, reactive pulse |
Active power pulse output | 5V, 10mA |
Power pulse input | |
Energy pulse type | Support active and reactive pulse, the highest frequency power pulse input is 200K. |
Pulse input channel | 1, 3 optional |
Communication port | |
Communication port | RS232, USB2.0 |
Standard | |
Standard | IEC62053-21,22,23; IEC60736; ANSI C12.20-2002; JJG 597-2005; JJG596-2012; JJG 1085-2013; JJF 68-2019; DL/T 826-2002; DL/T 1478-2015; DL/T 448-2016 |
Safety | |
Isolation protection | IEC61010-1:2001 |
Measurement category | 300V CAT III, 600V CAT II |
Degree of protection | IP42 |
Declaration of conformity | CE & CNAS certified |
Mechanical parameters | |
Dimensions (W×D×H)(mm) | 495 × 390 × 195 |
Weight (kg) | 12.8, 22.8 |
Environmental conditions | |
Ambient temperature | -10°C to +50°C |
Relative humidity | 35%-85% |
(1)RG means range, the same as below; (2)RD means the setted harmonic content, harmonic can be a single output, also multiple output. | |