Digital Leakage Current Clamp Meter GF6018A Multimeter Calibrator, CE, ISO Approved

Product Details
Customization: Available
After-sales Service: 24 Hours Service
Warranty: 3 Years Warranty
Gold Member Since 2013

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
5000000 RMB
Plant Area
>2000 square meters
  • Digital Leakage Current Clamp Meter GF6018A Multimeter Calibrator, CE, ISO Approved
  • Digital Leakage Current Clamp Meter GF6018A Multimeter Calibrator, CE, ISO Approved
  • Digital Leakage Current Clamp Meter GF6018A Multimeter Calibrator, CE, ISO Approved
  • Digital Leakage Current Clamp Meter GF6018A Multimeter Calibrator, CE, ISO Approved
  • Digital Leakage Current Clamp Meter GF6018A Multimeter Calibrator, CE, ISO Approved
  • Digital Leakage Current Clamp Meter GF6018A Multimeter Calibrator, CE, ISO Approved
Find Similar Products

Basic Info.

Model NO.
GF6018A
Application
Mechanical Instrument, Electromagnetic Instrument
Power
Electricity
Voltage Output
0-1000V AC/DC
Current Output
0-24A AC/DC
Thermocouple (TC)
T
Resistance-Temperature Detector (RTD)
Pt500(385)
LCD Display
With LCD Display
Customized
Customized
Size
440X450X160mm
Weight
12kg
Relative Humidity
Less Than 85%Rh
Frequency
50/60Hz
Communication Port
RS232
Class
0.05
Harmonics
2-31th
Transport Package
Standard Export Carton
Specification
CE, ISO9001: 2008, IEC
Trademark
GFUVE
Origin
Beijing, China
Production Capacity
200PCS/Month

Product Description

Introduction of Digital leakage current clamp meter GF6018A clamp type multimeter Calibrator,CE,ISO approved,with excellent working performance

 
Digital Leakage Current Clamp Meter GF6018A Multimeter Calibrator, CE, ISO Approved
Digital Leakage Current Clamp Meter GF6018A Multimeter Calibrator, CE, ISO Approved
Digital Leakage Current Clamp Meter GF6018A Multimeter Calibrator, CE, ISO Approved



The device is according to verification regulation JJG124-2005 "ammeter, voltmeter, power table and resistance meter calibration regulations, JJF1075-2001" clamp ampere ammeter calibration the requirements of the "standards for the design of 0.05 magnitude AC and DC standard units.The source of the signals of the DSP and 16 high-speed digital-to-analog converters can control of the sine wave, distortion wave source.The display USES graphics standard 240 X 128 LCD monochrome screen, chart characters, showed clear.

Main Functions and Features
1.The device consists of a single-phase AC voltage standard resource, current standard resource and DC voltage, current standard resource of standard resource.
2.Have calibration function, which can according to the standard of external value, fixed standard resource output values.
3.The setting of the range for verification 1999 (9), 3999 (9) a display of the digital multimeter.
4.Manual and semi-auto inspection 0.2% and below levels of digital multimeter, an analogue meter installation type digital instrument, including DC analog output of digital instrument;All kinds of clamp ampere ammeter;Verification clamp ampere ammeter range for 200 A, 600 A, 1000 A.
5.To generate containing 2 ~ 31 harmonic wave distortion, the harmonic number, number, amplitude and phase of the harmonic wave to base wave all can be programmed control.
6.With RS232 interface and large capacity non-volatile memory, can store 500 blocks are inspection table test data.Through the PC software, the PC control this device automatic and manual inspection, and the results are processing and management.
 
Technical Data  
AC output  
Voltage range: 200 mV, 400 mV, 2 V, 4 V, 20 V, 100 V, 200 V, 500 V, 1000 V;
Current range: 20μA, 40μA, 200μA, 400μA, 2mA, 4mA, 20mA, 40mA, 0.2A, 0.5A, 2A, 5A, 10A, 20A;
Clamp ampere ammeter range: 200A, 600A, 1000A;
Adjusting range 0 ~ 120% (1000 V voltage except);
Adjust fineness 5 X 10-5;
Voltage, current output capacity 20 VA;
Voltage, current adjustment for accuracy ±(0.03% RD + 0.02% FS);
Voltage, current output stability ≤0.01% / 60 s;
Voltage, current waveform distortion degree ≤0.3%;
Sine wave output frequency range (45-65) N Hz (N = 1, 2, 3, ...31);
Sine wave frequency output fineness 0.001 N Hz (N = 1, 2, 3, ...31);
Phase adjustment range 0 ~ 359.99°;
Phase adjust fineness 0.01°;
Harmonic output 2 ~ 31times
range 0 ~ 20% (base wave ratings);
Harmonic phase fineness 0.01 °N (N for harmonic frequency, N = 2 and 4...31);
DC output  
Voltage range: 200mV, 400mV, 2V, 4V, 20V, 40V, 100V, 200V, 400V, 1000V;
Current range 20μA, 40μA, 200μA, 400μA, 2mA, 4mA, 20mA, 40 mA, 0.2A, 1A, 2.5A, 5A, 10A, 20A;
Voltage, current, adjusting range 0 ~ 120% (1000 V voltage except);
Voltage, current adjust fineness 5 X 10-5;
Voltage output capacity 20 W;
Current output capacity of 30 W;
Voltage, current adjustment for accuracy ±(0.03% RD + 0.02% FS);
Voltage, current output stability ≤0.01% / 60 s;
Voltage, current output ripple ≤1%.
Frequency output  
Sine wave output range (using AC voltage, current output provide) (45-65) N Hz (N = 1, 2, 3...31);
Fineness 0.001 N Hz (N = 1, 2, 3...31);
The setting accuracy 5 X 10-5;
Point 1 kHz square wave frequency output 5 kHz, 10 kHz, 50 kHz, 100 kHz, 200 kHz, 1000 kHz;
Square wave amplitude 4.5 V.
Electronic resistance box output  
Quantity process  
0 ~ 200 Ω, 200 ~ 400 Ω, 0 ~ 2 K Ω, 2 K Ω~ 4 K Ω, 0 ~ 20 K Ω, 20 K Ω~ 40 K Ω, 0 ~ 200 K Ω, 200 K Ω~ 400 K Ω, 0 ~ 2 M Ω, 2 M Ω~ 4 M Ω  

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More