GF302D 3*380V/120A Portable Three Phase Kwh Meter Calibration Equipment
Contact Supplier
Product Highlights
- High Precision Accuracy: Offers 0.05% and 0.02% measuring accuracy for reliable meter testing.
- Portable Design: Compact 500x600x175mm size, 22kg weight, suitable for lab or on-site use.
- Multi-Function Testing: Tests kWh, watt-hour, reactive energy, power factor, frequency, and phase angle.
- Automatic PC Control: RS232 port with PC software for automatic testing and report generation.
- High Stability: Best stability of 0.01%/2min ensures consistent and accurate measurements.
- Comprehensive Standards: Complies with IEC, ANSI, and JJG standards for global certification.
- Lifetime Support: Provides lifetime after-sales service and a 3-year warranty for peace of mind.
Product Attributes
- Customization
- Available
- After-sales Service
- Life Time Support
- Warranty
- 3 Years
- Model NO.
- GF302D
- Transport Package
- Strong Packaging
- Trademark
- GFUVE
- Origin
- China
Product Images of GF302D 3*380V/120A Portable Three Phase Kwh Meter Calibration Equipment
Find Similar Products
Product Description




The GF302D portable meter test equipment is used for grid corporation of measurement and energy test center, management department of power supply bureau, national energy measurement of testing authorities, and also used to test each kind of single/three phase kWh meter of industries and mining enterprises as well as electric meter manufacturers. Meanwhile, the meter test equipment also can be used as one high precision standard power source, voltage source and current source. Portable design, used in the laboratory or on site to auto check energy meter error.
FUNCTIONS
Testing kWh meter error;
Testing watt-hour meter error;
Testing reactive energy meter error;
Testing single/three phase ammeter error;
Testing single/three phase voltmeter error;
Testing three phase electronic meter error;
Testing single phase electronic meter error;
Testing single/three phase power meter error;
Testing single/three phase power factor error;
Testing single/three phase frequency meter error;
Testing three phase mechanical energy meter error;
Testing single/three phase phase angle meter error;
Testing single phase mechanical energy meter error;
FEATURES
The best stability 0.01%/2min.
With RS232 port, it can be programmable.
Frequency of each impulse input port can reach 200KHz.
Able to do multi-function test such as communication test.
With PC control software, it can be automatic test and generate test report.
Able to do change test caused by voltage influence, frequency influence and harmonic influence.
Current output from 1mA to 120A, Voltage output from 0.01V to 600V, Phase angle adjust from 0°to 359.999°.
Output of power source is speedy and stable, AC maximum output of each phase can reach 120A in maximum.
Voltage, current and phase position of each phase can be adjusted in split-phase, improving the flexibility of power source.
7-inch TFT color display touch screen, English menu, simple and convenient operation, commonly used functions and current basic load point can be controlled in one button.
Able to test basic error, shunt running, start, standard error automatically and manually in single-step of single/three phase, according to relative regulation of kWh meter.
PARAMETERS
| Electrical parameters | |
|---|---|
| Accuracy | 0.05%, 0.1% |
| Power Supply | One Phase AC 100-265V, frequency 50/60Hz. |
| AC Voltage Output | |
| Range(U1,U2,U3) | 57.7V, 100V, 220V, 380V; Max 500V or 69.3V, 120V, 240V, 480V( optional); Max 600V |
| Adjustment range | (0-120)%RG(1) |
| Adjustment fineness | 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional. |
| Stability | 0.01%/120s |
| Distortion | 0.3% (Non-capacitive load) |
| Output load | each phase 25VA, 50VA, 100VA |
| Measuring accuracy | 0.05%RG or 0.02%RG |
| AC Current Output | |
| Range(I1,I2,I3) | 200mA, 1A, 5A, 20A, 100A; Max 120A |
| Adjustment range | (0-120)%RG |
| Adjustment fineness | 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional. |
| Stability | <0.01%/120s |
| Distortion | ≤0.3% (Non-capacitive load) |
| Output load | 50VA or 100VA |
| Accuracy | 0.05%RG or 0.02%RG |
| Power Output | |
| Active power output stability | <0.01%RG/120s |
| Reactive power output stability | <0.02%RG/120s |
| Active power measuring accuracy | 0.05%RG |
| Reactive power measuring accuracy | 0.1%RG |
| Apparent power measuring accuracy | 0.05%RG |
| Phase Output | |
| Output adjustment range | 0°-359.999° |
| Output adjustment fineness | 10, 1, 0.1, 0.01 as optional. |
| Resolution | 0.01° |
| Accuracy | 0.02° or 0.05° |
| Power Factor | |
| Adjustment range | -1 ~ 0 ~ 1 |
| Resolution | 0.0001 |
| Measurement accuracy | 0. 0005 |
| Frequency Output | |
| Adjustment range | 40Hz-70Hz |
| Output adjustment fineness | 5Hz, 1Hz, 0.1Hz, 0.01Hz as optional. |
| Resolution | 0.001Hz |
| Accuracy | 0.002Hz |
| Voltage /Current/Harmonic Setting | |
| Harmonic number | 2-51times or 2-63times |
| Harmonic content | 0-40% |
| Harmonic phase | 0-359.99 |
| Harmonic setting accuracy | (10%±0.1%)RD(2) |
| Power Energy Measurement Error | |
| Active power energy | 0.05%RG |
| Reactive power energy | 0.1%RG |
| Power Pulse Output | |
| Power pulse type | active pulse, reactive pulse |
| Active power pulse output | 5V, 10mA |
| Power Pulse Input | |
| Energy pulse type | support active and reactive pulse, the highest frequency power pulse input is 180K. |
| Communication Port | |
| Communication Port | RS232 |
| Standard | |
| Standard | IEC 62053-21,22, 23; IEC 60736; ANSI C12.20-2002; JJG 597-2005; JJG596-2012; JJG 1085-2013; JJF 68-2019; DL/T 826-2002; DL/T 1478-2015; DL/T 448-2016 |
| Safety | |
| Isolation protection | IEC 61010-1:2001 |
| Measurement Category | 300 V CAT III, 600 V CAT II |
| Degree of protection | IP20 |
| Declaration of conformity | CE certified |
| Mechanical parameters | |
| Dimensions (W×D×H) (mm) | 500x600x175 |
| Weight (kg) | 22 |
| Environmental conditions | |
| Ambient temperature | -10°C to +40°C |
| Relative humidity | 35%-85% |
| (1) RG means range, the same as below; (2) RD means the setted harmonic content, harmonic can be a single output, also multiple output. |
|
About the Supplier
Company Profile
Beijing GFUVE Electronics Co., Ltd. Was established in 2005. It combined science, industry and trade together as one high-tech enterprise. GFUVE mainly produces split core current transformer, high voltage ammeter recorder, IEC61850 test suite software, meter test equipment, current probe, reference standard meter, phantom load power source, electrical measurement instrument, relay test set, transformer test, CT analyzer, Test equipment, and power meter, power analyzer, intelligent digital meter, transducer, handheld terminal and split core current transformer, voltage transformer and current transformer models etc.
GFUVE is a leader manufacturer of energy meter test products and high voltage ammeter recorder in China. It is professional in energy meter test system, energy meter portable tester and related accessory of current probe. The product of high voltage ammeter recorder develops very quickly in the market. Our company has achieved certification to ISO9001. The products are sold to over 30 provinces in China and exported to overseas including South America, Middle East, South east and Africa.
We have been contributing ourselves to developing the durable and stable products for the usage of the power system. Contact us now for further business relationship. We are here to provide you the best service.
About Our Factory & Business Background
- Address
- Bldg. 2-1111, Joy Mansion, No. 99 Chaoyang North Road, Chaoyang District, Beijing, China
- Terms of Payment
- LC, T/T, PayPal, Western Union
- International Commercial Terms(Incoterms)
- FOB, CIF, FCA, EXW
- Average Lead Time
-
Peak Season Lead Time: one month
Off Season Lead Time: within 15 workdays - Nearest Port
- TIANJING
Our Production Capability & Technical Expertise
Our Industry Experience & Global Business Record
- Export Year
- 2010-08-01
- Main Markets
- North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe
FAQ
- What is the measuring accuracy of the GF302D?
- The equipment offers high precision with measuring accuracy options of 0.05%RG or 0.02%RG.
- Can this device be used for on-site testing?
- Yes, its portable design allows it to be used in laboratories or on-site for auto-checking energy meter errors.
- What is the maximum current output?
- The AC maximum output of each phase can reach 120A, with a range from 1mA to 120A.
- Does it support automatic testing and reporting?
- Yes, with PC control software via RS232, it can perform automatic tests and generate test reports.
- What is the warranty period?
- We provide a 3-year warranty along with lifetime after-sales support.
- What standards does the equipment comply with?
- It complies with IEC 62053-21/22/23, ANSI C12.20-2002, and various JJG and DL/T standards.
- What is the lead time for orders?
- Peak season lead time is one month, while off-season lead time is within 15 workdays.
- What payment terms are accepted?
- We accept LC, T/T, PayPal, and Western Union as terms of payment.
Send your message to this supplier
People who viewed this also viewed
-
US$80.00 / Piece
-
US$80.00 / Piece
-
US$80.00 / Piece
-
US$30.00 / Piece
-
US$30.00 / Piece
Find Similar Products By Category
- Supplier Homepage
- Products
- Meter Test Equipment
- kWh meter test equipment
- GF302D 3*380V/120A Portable Three Phase Kwh Meter Calibration Equipment
Related Categories
Hot Searches
- China Meter Factories
- Water Meter Factories
- Electronic Meter Factories
- Electric Meter Factories
- Digital Meter Test Equipment
- Computer Control Meter Test Equipment
- Portable Meter Test System
- Electronic Load Meter Test Equipment
- Manual Control Meter Test Equipment
- Top 10 Meter
- Meter Trends
- Portable Meter Test Equipment Bulkbuy