• with Battery Portable Precision Current Transformer Testing CT PT Analyzer
  • with Battery Portable Precision Current Transformer Testing CT PT Analyzer
  • with Battery Portable Precision Current Transformer Testing CT PT Analyzer
  • with Battery Portable Precision Current Transformer Testing CT PT Analyzer

with Battery Portable Precision Current Transformer Testing CT PT Analyzer

Application: Electromagnetic Instrument
Power: Electricity
Certification: FDA, CE, IAF, CCC
Voltage Output: 0-100vrms
Current Output: 0-5arms (20A Peak-Value)
LCD Display: With LCD Display
Customization:
Gold Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
GF1061
Customized
Customized
Keyword
Portable CT PT Analyzer
Model
Current Transformer Testing CT PT Analyzer
GF1061
CT PT Analyzer
Accuracy
0.05%
Automatic Frequency Variation Range
0.1-60Hz
Weight (Kg)
4
LCD
7 Inch Touch Color TFT LCD
Ratio
CT: 1-50000; PT: 1-10000
Phase Error
1 Min
Ratio Error
0.02%
Transport Package
Standard Export Wooden Box
Specification
280 x 250 x 160
Trademark
GFUVE
Origin
Beijing, China
HS Code
888550000
Production Capacity
1000pieces/Month

Product Description

GF1061 Portable Precision Current Transformer Testing CT PT Analyzer With Battery

GF1061 portable CT PT analyzer is mainly used for field or lab testing, it can finish the measurements (M) and protection (P) class CT, PT and TYP class CT. Adopt 7 inch touch TFT LCD, self-equipped mini type printer supporting field printing; supporting to use USB flash disk to dump data. The CT PT Analyzer is the most complete and easy-to-use testing system for protection and metering CTs according to IEEE and IEC standards.
with Battery Portable Precision Current Transformer Testing CT PT Analyzer

Main functions
I. Current Transformer (CT) II. Voltage Transformer (PT)
1. Magnetization curve 1. Excitation characteristic test
2. Transformation ratio test 2. Transformation ratio test
3. Polarity 3. Polarity 
4. 5% and 10% error curve 4.  Ratio error, phase error
5. Accuracy limiting factor (ALF) 5. Degauss
6. Degauss 6. Calculation of knee point value
7. Ratio error, phase error 7. Actual secondary load test (burden test)
8. Automatic calculation of excitation knee
point value
8. Resistance test
9. Actual secondary load test (burden test)
10. Resistance test
11. Secondary time constant (Ts)
12. Remanence coefficient (Kr)
13. Transient dimensioning factor (Ktd)
14. Peak instantaneous error (Er)
15. Magnetizing inductance (LU)
16. Instruments security factor(FS)
17. Composite error
Parameters
Electrical parameters
Accuracy 0.05%
Power supply AC 220V±10% or AC 120V±10%, 50/60Hz or Battery
Output voltage 0-100Vrms
Output current 0-5Arms (20A peak-value)
Output power 0-400 VA (1500 VApeak)
Automatic frequency variation range 0.1-60Hz
Equivalent excitation voltage ≤5000V
Accuracy ≤0.5%
Secondary winding DC resistance measurement Range 0.1-1000Ω
Accuracy ≤0.05%
Secondary actual load measurement Range 5VA-1000VA
Accuracy ≤0.5%±0.1VA
CT/PT phase error measurement Accuracy ±1min (typical) / 3 min (guaranteed)
Resolution 0.1min
CT ratio error measurement Range 1-50000
Accuracy ≤0.05%
PT ratio error measurement Range 1-10000
Accuracy ≤0.05%
Standards
Reference standards GB1207-2006, GB1208-2006, GB16847-1997
IEC60044-1, IEC60044-6, IEC61869-2, ANSI/IEEE C57.13
Safety standards GB 4793.1-2007
EMC EMC standard 89/336/EEC
FCC Subpart B of Part 15 Class A
IEC 1000-4-2 /3 /4 /6
Mechanical parameters
Overall dimension (L x W x H) (mm) 280 x 250 x 160
Weight (kg)   ≤4
Environmental conditions
Relative humidity    Relative humidity 5%-95% not condensing
Operating temperature -10°C to +50°C
Storage temperature -20°C to +70°C
Altitude ≤1000m
with Battery Portable Precision Current Transformer Testing CT PT Analyzer
http://guangfuhui.en.made-in-china.com
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now