GF106 CT Test Equipment with Knee Point

Product Details
Customization: Available
Warranty: 3 Years
CT/PT Phase Error Measurement Accuracy: ±3min
Diamond Member Since 2013

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
5000000 RMB
Plant Area
>2000 square meters
  • GF106 CT Test Equipment with Knee Point
  • GF106 CT Test Equipment with Knee Point
  • GF106 CT Test Equipment with Knee Point
  • GF106 CT Test Equipment with Knee Point
  • GF106 CT Test Equipment with Knee Point
  • GF106 CT Test Equipment with Knee Point
Find Similar Products

Basic Info.

Model NO.
GF106
CT/PT Phase Error Measurement Resolution
0.01min
CT Ratio Error Measurement Range
1-30000
CT Ratio Error Measurement Accuracy
≤0.05%
PT Ratio Error Measurement Range
1-10000
PT Ratio Error Measurement Accuracy
≤0.05%
Specification
410 x 250 x 300
Origin
China

Product Description

GF106

CT TEST EQUIPMENT WITH KNEE POINT

GF106 CT Test Equipment with Knee Point

GF106 CT test set (CT Analyzer) is a current transformer test equipment specially designed for current transformer characteristic test and with additional PT test functions for reference test. GF106 CT test equipment is mainly used for field testing, it can finish the measurements (M) and protection (P) class CT, PT and TYP class CT. GF106 CT test equipment can also guessed CT ratio test equipment because of the additional functions including ratio and angle differential tests (the measurement points in the IEC60044 & IEC61869 standard), FS and inductance, steady-state parameters, peak error and transient parameters, etc. Adopt 5.6 inch LCD, self-equipped mini type printer supporting field printing; supporting to use USB flash disk to download data, with simple and convenient operation.

FEATURES

Portability: weight <8kg;

In-built PT test functions;

CT ratio error test accuracy 0.05%;

The device can store 3000 groups of test data;

With it thermal printer, printing test results on site;

Parameters such as knee point current and voltage;

Parameters such as 10% error curve, 5% error curve;

Test CT according to IEC60044-1/6, IEC61869-2, ANSI C57.13;

Steady and transient state characteristic tests of various types of CT/PT;

No external other auxiliary equipment, stand-alone to complete all test items;

The use of advanced power technology, the test knee point reaches up to 45kV;

The testing data can be transferred to PC by USB disk and produce test report;

CT easy to test, all the tests are using the same wire connection except burden test;

APPLICATION

Power plant;

Electrical laboratory;

Metrological service center;

Electricity power bureau & power company;

National Metrology and testing department;

Power engineering commissioning company;

Current transformer and voltage transformer factory;

Electrical Department of industrial and mining enterprises;

PARAMETERS

Electrical parameters
Secondary winding DC resistance measurement Range 0.1-300Ω
Accuracy ≤0.1%
Secondary actual load measurement Range 0.1VA-1000VA
Accuracy ≤0.1%
CT/PT phase error measurement Accuracy ±3min
Resolution 0.01min
CT ratio error measurement Range 1-30000
Accuracy ≤0.05%
PT ratio error measurement Range 1-10000
Accuracy ≤0.05%
LCD display 5.6' inch blacklight LCD
Cable Length Primary 5m; Secondary 5m; others customized
Communication port USB
PC control software Yes, Optional
Printer Yes, Thermal printer
Standards
Reference standards GB1207-2006, GB1208-2006, GB16847-1997
IEC60044-1, IEC60044-6, IEC61869-1,2,3, ANSI/IEEE C57.13
Safety standards GB 4793.1-2007
EMC EMC standard 89/336/EEC
FCC Subpart B of Part 15 Class A
IEC 1000-4-2/3/4/6
Mechanical parameters
Overall dimension (L x W x H) (mm) 410 x 250 x 300
Weight (kg) ≤8
Environmental conditions
Operating Temperature -10°C to 50°C
Storage Temperature -40°C to 70°C
Relative humidity ≤95%,on-condensing
Altitude ≤2000m

MAIN FUNCTIONS

I. Current Transformer (CT) II. Voltage Transformer (PT)
1. Magnetization curve 1. Excitation characteristic test
2. Transformation ratio test 2.  Transformation ratio test
3. Polarity 3.  Polarity
4. 5% and 10% error curve 4.  Ratio error, phase error
5. Current Injecting(Optional) 5.  Degauss
6. Degauss 6.  Calculation of knee point value
7. Ratio error, phase error 7. Actual secondary load (PT connected burden) test
8. Automatic calculation of excitation knee point value 8. Resistance test
9. Actual secondary load (Current loop burden) test
10. Resistance test
11. Secondary winding time constant (Ts)
12. Remanence coefficient (Kr)
13. Transient dimensioning factor (Ktd)
14. Peak instantaneous error (Er)
15. Magnetizing inductance (LU)
The test items mainly include
Steady Transient
Excitation characteristic Secondary winding time constant (Ts)
Transformation ratio Remanence coefficient (Kr)
Polarity Transient dimensioning factor (Ktd)
Ratio error Peak instantaneous error (Er)
Phase error Magnetizing inductance (LU)
5% and 10% error curves Other parameters
Resistance
Secondary load
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More