Gfuve High Voltage Circuit Breaker Analyzer T-209

Product Details
Customization: Available
Certification: CCC
Protection: Corrosion Resistance
Still deciding? Get samples of $ !
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW PayPal
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2013

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
5000000 RMB
Plant Area
>2000 square meters
  • Gfuve High Voltage Circuit Breaker Analyzer T-209
  • Gfuve High Voltage Circuit Breaker Analyzer T-209
  • Gfuve High Voltage Circuit Breaker Analyzer T-209
  • Gfuve High Voltage Circuit Breaker Analyzer T-209
  • Gfuve High Voltage Circuit Breaker Analyzer T-209
  • Gfuve High Voltage Circuit Breaker Analyzer T-209
Find Similar Products

Basic Info.

Model NO.
GF302D1
Installation
Hanging
Housing
UPR
Accuracy
0.02%, 0.05%, 0.1%
Power Supply
One Phase AC 85-265V, Frequency 50/60Hz.
Output Load
Each Phase 25va
Range (U1, U2, U3)
0-600V; 0-500V; 0-380V; 0-300V;
Degree of Protection
IP42
Transport Package
Wooden Box
Specification
Phasor checker: 187×119×48mm Detector
Trademark
GFUVE
Origin
Beijing
HS Code
9107000000
Production Capacity
1000

Packaging & Delivery

Package Size
495.00cm * 390.00cm * 195.00cm
Package Gross Weight
12.800kg

Product Description

GF302D1THREE PHASE PORTABLE ENERGY METER TEST EQUIPMENT

The GF302D1 three phase portable energy meter test equipment consists of an integrated three phase current source(up to 500V/120A or 500V/20A) and built-in three-phase electronic reference standard of accuracy class 0.02% or 0.05%. Characteristic features of the GF302D1 are its wide measuring range, high accuracy and high tolerance to unwanted external influences. The equipment offers high functionality combined with an excellent menu guided operation via built-in keyboards and colored 7" touch LCD-display. Voltage & current harmonics output from 2 to 63 times. This model portable meter test equipment can be programmable by PC, automatic generation of energy meter error test report.
Gfuve High Voltage Circuit Breaker Analyzer T-209Gfuve High Voltage Circuit Breaker Analyzer T-209Gfuve High Voltage Circuit Breaker Analyzer T-209Gfuve High Voltage Circuit Breaker Analyzer T-209Gfuve High Voltage Circuit Breaker Analyzer T-209Gfuve High Voltage Circuit Breaker Analyzer T-209Gfuve High Voltage Circuit Breaker Analyzer T-209Gfuve High Voltage Circuit Breaker Analyzer T-209Gfuve High Voltage Circuit Breaker Analyzer T-209Gfuve High Voltage Circuit Breaker Analyzer T-209Gfuve High Voltage Circuit Breaker Analyzer T-209Gfuve High Voltage Circuit Breaker Analyzer T-209Gfuve High Voltage Circuit Breaker Analyzer T-209Gfuve High Voltage Circuit Breaker Analyzer T-209Gfuve High Voltage Circuit Breaker Analyzer T-209Gfuve High Voltage Circuit Breaker Analyzer T-209Gfuve High Voltage Circuit Breaker Analyzer T-209Gfuve High Voltage Circuit Breaker Analyzer T-209Gfuve High Voltage Circuit Breaker Analyzer T-209Gfuve High Voltage Circuit Breaker Analyzer T-209
 

FUNCTIONS

Register test

Harmonics test

Energy meter accuracy test

Repeatability of error test

Measuring the distortion factor

User friendly menu guided operation

Energy dosing with built-in current source

Measuring mechanical meter and electric meter

Measuring frequency, phase shift and power factor

Automatic operation without need of an external PC

Easy verification and analysis of meter installations

Three phase ballance test and Three phase unballance test

Testing all kinds of energy meter in 1P2W, 1P3W, 3P3W, 3P4W

Especially configured USB stick for storage of customer data

Power and energy measurements for active, reactive and apparent power

Harmonic spectrum analysis for voltage and current up to the 63nd order

Vector diagram display and phase sequence indication on integrated colored screen

 

FEATURES

Weight light 12.8Kg

0-120A/0-500V/40-70Hz

7 inch TFT touch screen

Test by automatic or manual

Accuracy class 0.02 or 0.05

Start testing and creep testing

Recorder 500 sets energy meter data

Display all electrical parameters on one screen

Reference standard and current source integrated

Overload, short circuit, open circuit protection

 

PARAMETERS

Electrical parameters
Accuracy 0.02%, 0.05%, 0.1%
Power supply One phase AC 85-265V, frequency 50/60Hz.
AC voltage output
Range (U1, U2, U3) 0-600V; 0-500V; 0-380V; 0-300V;
Adjustment range (0-120)%RG(1)
Adjustment fineness 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional.
Stability 0.01%/120s
Distortion 0.3% (Non-capacitive load)
Output load Each phase 25VA
Accuracy 0.02%RG or 0.05%RG
AC current output
Range (I1, I2, I3) 0-6A; 0-12A; 0-20A; 0-50A; 0-120A;
Adjustment range (0-100)%RG
Adjustment fineness 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional.
Stability <0.01%/120s
Distortion ≤0.3% (Non-capacitive load)
Max output load 20VA or 50VA or 100VA;
Accuracy 0.02%RG or 0.05%RG
Power measurement
Active power output stability <0.01%RG/120s
Reactive power output stability <0.02%RG/120s
Active power measuring accuracy 0.02%RG or 0.05%RG
Reactive power measuring accuracy 0.05%RG or 0.1%RG
Phase output
Output adjustment range 0°-359.999°
Output adjustment fineness 10, 1, 0.1, 0.01 as optional.
Resolution 0.01°
Accuracy 0.015°
Power factor
Adjustment range -1 ~ 0 ~ 1
Resolution 0.0001
Measurement accuracy 0.0005
Frequency measurement
Range 40Hz-70Hz
Resolution 0.001Hz
Accuracy 0.002Hz
Voltage/current/harmonic setting
Harmonic number 2-63times
Harmonic content 0-40%
Harmonic phase 0-359.99
Harmonic setting accuracy (10%±0.1%)RD(2)
Power energy measurement error
Active power energy 0.02%RG or 0.05%RG
Reactive power energy 0.05%RG or 0.1%RG
Power pulse output
Power pulse type Active pulse, reactive pulse
Active power pulse output 5V, 10mA
Power pulse input
Energy pulse type Support active and reactive pulse, the highest frequency power pulse input is 200K.
Pulse input channel 1, 3 optional
Communication port
Communication port RS232, USB2.0
Standard
Standard IEC62053-21,22,23; IEC60736; ANSI C12.20-2002;
JJG 597-2005; JJG596-2012; JJG 1085-2013; JJF 68-2019;
DL/T 826-2002; DL/T 1478-2015; DL/T 448-2016
Safety
Isolation protection IEC61010-1:2001
Measurement category 300V CAT III, 600V CAT II
Degree of protection IP42
Declaration of conformity CE & CNAS certified
Mechanical parameters
Dimensions (W×D×H)(mm) 495 × 390 × 195
Weight (kg) 12.8, 22.8
Environmental conditions
Ambient temperature -10°C to +50°C
Relative humidity 35%-85%
(1)RG means range, the same as below;
(2)RD means the setted harmonic content, harmonic can be a single output, also multiple output.