• GF302 USB RS232 Portable Multifunction Instrument Calibrator Transducer Calibrator
  • GF302 USB RS232 Portable Multifunction Instrument Calibrator Transducer Calibrator
  • GF302 USB RS232 Portable Multifunction Instrument Calibrator Transducer Calibrator
  • GF302 USB RS232 Portable Multifunction Instrument Calibrator Transducer Calibrator
  • GF302 USB RS232 Portable Multifunction Instrument Calibrator Transducer Calibrator
  • GF302 USB RS232 Portable Multifunction Instrument Calibrator Transducer Calibrator

GF302 USB RS232 Portable Multifunction Instrument Calibrator Transducer Calibrator

Accuracy: 0.05%
AC Voltage: 600V
AC Current: 20A
Frequency: 45-65Hz
Harmonic: 2-31st
Isolation Protection: IEC61010-1:2001
Customization:
Gold Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
GF302
Transport Package
Standard Export Carton
Specification
CE. ISO9001: 2008, standard IEC
Trademark
GFUVE
Origin
Beijing, China
Production Capacity
50PCS/Month

Product Description

GF302 PORTABLE HIGH PRECISION MULTI-PRODUCT CALIBRATOR
FUNCTIONS AND FEATURES

GF302 USB RS232 Portable Multifunction Instrument Calibrator Transducer Calibrator
GF302 USB RS232 Portable Multifunction Instrument Calibrator Transducer Calibrator
GF302 USB RS232 Portable Multifunction Instrument Calibrator Transducer Calibrator

  • All kinds of electric measurement transducer can be checked, includingAC/DC voltage transducer, AC/DC current transducer, frequency transducer, phase transducer, single/ three-phaseAC active power transducer, three-phase reactive power transducers
  • Check all kinds of electric measurement indicating meter, includingAC/DC voltmeter, AC/DC ammeter, frequency meter, phase meter, single three-phase ac active power meter, three-phase ac reactive power meter, synchronous meter, etc
  • Test single-phase, three-phase electronic, mechanical watt-hour meter or energy meter/ kWh meter error
  • Calibrate AC sample device, RTU, measurement device error
  • The built-in electric measurement transducer, electric measurement instrument and meter instructions of verification procedures, can fully automatic or semi-automatic for verification, and save 1000 group check data
  • It can be used as voltage source, current source and power source with high precision, and it isa high stability standard resource
  • 6.4-inch big screen color display and English interface
  • For the software calibration, you don't need to open the case, it's stable and reliable
  • Voltage output terminal with short circuit, current output terminal open protection and power amplifier overheating protection function
  • With automatic failure detection function, shows fault part, the convenience users check line
  • With USB port, it can connect computer for data management or controlled by PC
 

PARAMETERS

Electrical parameters
Accuracy class 0.05%, 0.1%
Power supply Single phase AC 220V±10% or 110V±10%, 50/60Hz
Communication port USB, RS232
AC Voltage output
Range(U1,U2,U3) 50V, 100V, 200V, 400V, 600V
Adjusting range (0-120)% RG
Adjust fineness 0.005% RG
Accuracy 0.05% RG
Stability 0.01% / 1 min
Load capacity 25VA
Output distortion degree ≤0.3% or (linear load)
AC Current output
Range(I1,I2,I3) 0.5A, 1A, 2.5A, 5A, 10A, 20A
Adjusting range (0-120)% RG
Adjust fineness 0.005% RG
Accuracy 0.05% RG
Stability 0.01%/1 min
Load capacity 25VA
Output distortion degree ≤0.3% or (linear load)
AC Power output
Accuracy 0.05% RG
Stability 0.01%/1min
Frequency
Frequency range 45.000 - 65.000 Hz
Resolution 0.001 Hz
Accuracy 0.002 Hz
Power factor output
Adjusting range -1 ~ 0 ~ 1
Adjust fineness 0.0001
Accuracy 0.0005
Phase angle
Scope 0°-359.99°
Resolution 0.01°
Accuracy 0.05°
Voltage/Current harmonic output
Times 2-31st
Content 0-40%
Phase 0-359.999 degree
Configuration error (10% RD + 0.1%), RD refers to the configuration value of harmonic contents
DC Voltage output
Range 75mV, 75V, 150V, 300V, 500V, 1000V
Adjusting range (0-120)% RG
Adjust fineness 0.005% RG
Accuracy 0.05% RG
Stability 0.01%/1min
Load capacity 25VA
DC Current output
Range 0.5A, 1A, 2.5A, 5A, 10A, 20A
Adjusting range (0-120)% RG
Adjust fineness 0.005% RG
Accuracy 0.05% RG
Stability 0.01%/1min
Load capacity 25VA
DC measurements
DC voltage measurement range 0 to ±24V
DC current measurement range 0 to ±24mA
Measurement accuracy 0.01% RG
Watt-hour meter measuring the integrated error
Active energy 0.05%
Reactive energy 0.1%
Mechanical parameters
Dimensions (W×H×D) (mm) 460x430x185
Weight (kg) 20
Environmental conditions
Working temperature 0°C to 40°C
Storage conditions -30°C to 60°C
Relative humidity ≤85%

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now