Secured Trading Service

Secured Trading Service

What is STS?

STS is an escrow service that protects both buyers and suppliers. Funds are held securely by Made-in-China.com until order terms (e.g., delivery, quality) are fulfilled

Key Advantages

Payment Protection:
Your payment is only released to the supplier after you confirm satisfactory delivery.Suppliers receive payment only upon your approval.
Dispute Resolution:
If issues arise (e.g., quality discrepancies, shipping delays), our team mediates and facilitates resolutions based on evidence.
Flexible Payment Options:
Supports credit cards (Visa/MasterCard), PayPal, Apple Pay, Google Pay, many local payment methods and T/T (bank transfer).

GF438II Handheld Three Phase Power Quality Analyzer for Grid Troubleshooting

Product Details
Customization: Available
After-sales Service: Three Years
Warranty: Three Years
Shipping
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Online Trading Protection
Payment Guarantee
T/T PayPal ApplePay GooglePay visa mastercard american express discover JCB diners club PIX SPEI OXXO PSE OZOW Platform-protected payments with refund support for eligible order issues.
Platform Logistics
Clearer shipment tracking with platform-supported logistics.
Inspection Service
Optional pre-shipment inspection for quality and quantity checks.
After-Sales & Dispute Handling
Platform-assisted dispute resolution, including refunds or returns when applicable.
Only orders placed and paid through Made-in-China.com Secured Trading are eligible for payment protection and the corresponding platform services.
Diamond Member Since 2013

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Address
Bldg. 2-1111, Joy Mansion, No. 99 Chaoyang North Road, Chaoyang District, Beijing, China
International Commercial Terms(Incoterms)
FOB, CIF, FCA, EXW
Terms of Payment
LC, T/T, PayPal, Western Union
  • GF438II Handheld Three Phase Power Quality Analyzer for Grid Troubleshooting
  • GF438II Handheld Three Phase Power Quality Analyzer for Grid Troubleshooting
  • GF438II Handheld Three Phase Power Quality Analyzer for Grid Troubleshooting
  • GF438II Handheld Three Phase Power Quality Analyzer for Grid Troubleshooting
  • GF438II Handheld Three Phase Power Quality Analyzer for Grid Troubleshooting
  • GF438II Handheld Three Phase Power Quality Analyzer for Grid Troubleshooting
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
Overview

Basic Info.

Model NO.
GF438II
Transport Package
Carton Box
Specification
263mm x 168mm x 65mm
Trademark
GFUVE
Origin
China

Product Description

Product Description

 

GF438II handheld three phase power quality analyzer supports the measurement of 50 Hz and 60 Hz power frequency system. It can record and analyze different types of power quality parameters such as voltage, current, harmonic, frequency, fluctuation, flicker, swell,sag, power and three-phase unbalance of power supply line. It has advanced power quality measurement function and provides professional upper computer GFUVEPQA analysis software for secondary analysis and report file. To provide users with the most accurate power fault diagnosis analysis. And there are Ethernet, input contact, output contact, USB and other communication ports, which can flexibly carry out network communication.
 

PARAMETERS

Name Measurement type
Voltage rms, ava, pk+, pk-, rms-1/2, CF
Frequency Freq
Current rms, ava, pk+, pk-, rms-1/2, CF
Power & energy P, S, Q, PF, DPF, W
Computation THD, DC, 1-63 Harm, 1-62 InHarm, 1-35 HiHarm, 1-62 SubHarm
Voltage harmonic THD, DC, 1-63 Harm, 0-62 InHarm, 1-35 HiHarm, 1-62 SubHarm , KF
Current harmonic THD, DC, 1-63 Harm
Harmonic power Ia, Ib, Ic, ΣPtotal, ΣQtotal, ΣStotal, 15 minutes
Fluctuation and flickering PST, PLT, Fluct, Fluct Max
Unbal V Pos, A pos , V neg , A neg , V zero, A zero, Unbal
Event log Voltage swell, voltage sags, DIP, surge current, voltage and current distortion out of limit, odd harmonics containing rate out of limited, unbalanced voltage current out of limit, frequency out of limit, PST out of limit, PLT out of limit, long-term voltage interruption, voltage fluctuation deviation, voltage harmonics out of limit, 2-25st harmonics out of limit
P, Q, S name Measurement type
Measurement types P: Calculate by every 10 cycles
S: Calculated by the effective value of voltage and current
Q: Calculated by the apparent power, active power
Display Table charts, trend chart
Measuring range According to the range of the voltage and current
Resolution 0.001W
Accuracy ±0.5%
Urms Measurement type
Mode Calculated by the square root value of 10/12 cycle
Measuring circuit 1P2W/ 2P3W /3P3W/ 3P4W
Basic frequency of the measuring circuit 50Hz, 60Hz
Input channels 4 channel voltage, 4 channel current
Display mode Effective current value of each channel
Range 120V, 230V, 400V, 1000V, Max 1000V instantaneous voltage
Resolution 0.001V
Accuracy 0.1% RG
Arms Measurement type
Mode Calculated by the square root value of 10/12 cycle
Display mode Effective current value of each channel
Range Current: according to the current clamps
Option Current clamps:5A/50A/100A/500A/1000A
Flexible Current probe: 3000A/6000A
Resolution 0.001A
Accuracy 0.1% + accuracy of the current clamps
Frequency Measurement type
Measurement mode Calculate by 10 cycles (50Hz) or (60Hz)
Display mode Measurement by 10 cycles
Nominal frequency/resolution 50.000Hz/0.001Hz or 60.000Hz/0.001Hz
Bandwidth measurement 40Hz-70Hz
Accuracy ±0.001Hz
Half-wave RMS current/voltage Measurement type
Measurement mode Calculate by every 2 cycles. Each cycle ,1/2 cycle made up of a waveform calculation
Measuring range/resolution Voltage: 120V/0.01V, 230V/0.01V, 400V/0.01V, 1000V/0.01V,Current: According to the current clamps
measurement accuracy ±0.1%
Power factor Measurement type
Measurement mode The ratio of average power to apparent power
Display mode Real-time data showed
Measurement range/resolution -1.000-1.000/0.001
Accuracy ±0.1%
Vfund, Afund, Harmonic power Measurement type
Measurement mode Meet IEC61000-4-7,Analysis time window is ten cycles
Window points 5120 points
Display mode Form figure, trend charts, histograms
Number of measurement 1-50 Times(25Hz-3150Hz)
Measurement accuracy Vfund >1%: Error<1%
Vfund <1%: Error<0.05% Rated Voltage
Afund >3%: Error<1%
Afund <3%: Error<0.05% Current range
InHarm Voltage, InHarm current Measurement type
Measurement mode Meet IEC61000-4-7, Analysis time window is ten cycles
Window points 5120 points
Display mode Form figure, trend charts, histograms
Numbers of measurement 1-16 groups
Measurement accuracy Vfund >1%: Error<1%
Vfund <1%: Error<0.05% Rated Voltage
Afund >3%: Error<1%
Afund <3%: Error<0.05% Current range
HiHarm Voltage, HiHarm current Measurement type
Measurement mode Meet IEC61000-4-7, Analysis time window is ten cycles
Window points 5120 points every 10 cycles
Display mode Form figure, trend charts, histograms
Numbers of measurement 1-35 groups/2100Hz-8900Hz
Measurement accuracy Vfund >1%: Error<1%
Vfund <1%: Error<0.05% rated voltage
Afund >3%: Error<1%
Afund <3%: Error<0.05% current range
Voltage SubHarm Current SubHarm Measurement type
Measurement mode Meet IEC61000-4-7, analysis time window is ten cycles
Window points 5120 points every 10 cycles
Display mode Form figure, trend charts, histograms
Numbers of measurement 1-50 groups
Measurement accuracy Vfund >1%: Error<1%
Vfund <1%: Error<0.05% Rated Voltage
Afund >3%: Error<1%
Afund <3%: Error<0.05% Current range
Voltage/current Unbal (pos, neg) Measurement type
Measurement mode 3P3W or 3P4W, using three phase of fundamental wave components to calculate
Display mode Form figure, trend charts, histograms
Measurement accuracy Voltage unbal: ±0.2%
Current unbal: ±0.5%
Voltage fluctuation Measurement type
Measurement mode Calculate by the quadratic mean of half wave.
Display mode Form figure, trend charts
Measurement accuracy ±1%
IEC Flickering Measurement type
Measurement P short term (Pst) , P long term (Plt)
Measurement mode According to IEC61000-4-15 Standard to calculate Pst (10 mins) Plt (2 hours)
Display mode Form figure, trend charts
Measurement range 0-20
Measurement accuracy ±5%
Surge current Measurement type
Measurement mode Half-wave RMS of current is higher than set value and sustain time is 10ms-1min
Display mode Maximum of the surge current and surge current wave
Measurement accuracy 0.1%
Voltage swell, Voltage sags, DIP Measurement type
Measurement mode Swell: When half-wave RMS of voltage is higher than set value and sustain time is 10ms-1min, judged as swell.
Sags: When half-wave RMS of voltage is lower than set value and sustain time is 10ms-1min, judged as sags.
DIP: half-wave RMS of voltage is higher than set value and sustain time is 10ms-1min, judged as DIP
Display mode Swell, sags, DIP wave sustain time, extent and so on.
Measurement accuracy 0.1%
DC measurement
Voltage 4 channel DC voltage
Range 0-1000V
Accuracy 0.1%
Current 1 channel DC current
DC current clamp 200A, 500A, 1000A optional
Accuracy 0.2%
Machinery
Size 263mm x 168mm x 65mm
Key 21PCS
Binary binary input:1 ; binary output:1
Comunication Port USB, 10/100M port
Weight 1.6KG
Power supply
Voltage input 100V-265V
Adapter output 15V, 3A
Battery Rechargeable nickel metal hydride, 5500mAh
Battery working time ≥ 6h
Battery recharging time 5h (Environment temperature 25°C)
Power saving facility LCD backlight brightness is adjustable, standby time is adjustable
Display
Size 112.8 x 84.6mm
Color 260000 color
Resolutions 640 x 480
Brightness Max 350 cd/m2 (Typ), brightness is adjustable
Contrast 500:1 (Typ)
Visual angle 70/70/50/70 (Typ.)(CR ≥10) ( Left/ Right/ UP/Down)
Store
Type TF card (inbuilt)
Size 32G
Function
Vrms & Irms waveforms(8 channel) Yes
Power/Energy Yes
Voltage/Current harmonics Yes
Harmonics Power Yes
Flicker Yes
Unballance Yes
Inrush current Yes
Event log Yes
Transient monitoring Yes
Energy line loss Yes
Inverter measurement Optional
GPS Optional
Remote control Optional
Networking management Optional
PC software Yes
Environment
Working environment 0°C to +45°C, humidity below 90rh%
Storing environment -20°C to +50°C, humidity below 95rh% (non-condensing)
Standards
Measurement method IEC 61000-4-30
Measurement performance IEC 61000-4-30 A LVL, IEC 62586
Flickering IEC 61000-4-15
Harmonic IEC 61000-4-7, IEEE 519
Power IEEE 1459
Power quality compliance EN 50160
Safety
Standard GB 4793.1-2007/IEC 61010-1:2001: ""Measurement, control and laboratory electrical equipment safety requirements"", first part: general requirements. Security level: CAT III 1000 V/ CAT IV 600 V.
MAX voltage of phase angle input CAT III 1000V/CAT IV 600V
 
Detailed Photos

GF438II Handheld Three Phase Power Quality Analyzer for Grid TroubleshootingGF438II Handheld Three Phase Power Quality Analyzer for Grid TroubleshootingGF438II Handheld Three Phase Power Quality Analyzer for Grid TroubleshootingGF438II Handheld Three Phase Power Quality Analyzer for Grid TroubleshootingGF438II Handheld Three Phase Power Quality Analyzer for Grid TroubleshootingGF438II Handheld Three Phase Power Quality Analyzer for Grid Troubleshooting

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Send Inquiry
Chat Now
Product Groups
More