The device is according to verification regulation JJG124-2005 "ammeter, voltmeter, power table and resistance meter calibration regulations, JJF1075-2001" clamp ampere ammeter calibration the requirements of the "standards for the design of 0.05 magnitude AC and DC standard units.The source of the signals of the DSP and 16 high-speed digital-to-analog converters can control of the sine wave, distortion wave source.The display USES graphics standard 240 X 128 LCD monochrome screen
1.The device consists of a single-phase AC voltage standard resource, current standard resource and DC voltage, current standard resource of standard resource.
2.Have calibration function, which can according to the standard of external value, fixed standard resource output values.
3.The setting of the range for verification 1999 (9), 3999 (9) a display of the digital multimeter.
4.Manual and semi-auto inspection 0.2% and below levels of digital multimeter, an analogue meter installation type digital instrument, including DC analog output of digital instrument;All kinds of clamp ampere ammeter;Verification clamp ampere ammeter range for 200 A, 600 A, 1000 A.
5.To generate containing 2 ~ 31 harmonic wave distortion, the harmonic number, number, amplitude and phase of the harmonic wave to base wave all can be programmed control.
6.With RS232 interface and large capacity non-volatile memory, can store 500 blocks are inspection table test data.Through the PC software, the PC control this device automatic and manual inspection, and the results are processing and management.
Technical DataElectrical parametersAC Voltage outputAC Current OutputFrequency OutputHarmonic WaveDC voltage outputDC current outputResistance boxClamp meter rangeDot frequency square wave outputMechanical parametersEnvironmental conditions
Power supply | Single phase AC 220V±10% or 110V±10%, 50/60HzAC | |
range | 200mV, 400mV, 2000mV, 4000mV, 20V, 100V, 200V, 500V, 1000V; max 1050V |
|
Range 20V-1000V | Accuracy | ±(0.03%RD+0.02%FS) |
Stability | ≤0.01% FS /60s | |
Range 200mV-4000mV | Accuracy | ±(0.3%RD+0.2%FS) |
Stability | ≤0.04% FS /60s | |
Load capacity | 20VA | |
Waveform distortion | ≤0.3% | |
Adjustable Range | 0-120% FS (1000V not included) | |
Fineness | 5×10-5 | |
Range | 2mA, 4mA, 20mA, 40mA, 0.2A, 0.5A, 2A, 5A, 10A, 20A; max 24A | |
Range 0.2A-20A | Accuracy | ±(0.03%RD+0.02%FS) |
Stability | ≤0.01% FS /60s | |
Range 2mA-40mA | Accuracy | ±(0.3%RD+0.2%FS) |
Stability | ≤0.04% FS /60s | |
Load capacity | 20VA | |
Waveform distortion | ≤0.3% | |
Adjustable Range | 0-120% FS | |
Fineness | 5×10-5 | |
Range | 45-65Hz | |
Fineness | 0.001Hz | |
Accuracy | 0.01Hz | |
Times | 2-31 | |
Extent | 0-20% | |
Each harmonic phase fineness | 0.01·N (N is harmonic order) | |
Range | 200mV, 400mV, 2000mV, 4000mV, 20V, 40V, 100V, 200V, 400V, 1000V; max 1050V |
|
Load capacity | 20W | |
Adjustable range | 0-110% FS (1000V not included) | |
Adjustable fineness | 5×10-5 | |
Stability | ≤0.01% FS /60s (peak-peak value) | |
Accuracy | ±(0.03%RD+0.02%FS) | |
Ripple wave | ≤1% FS | |
Range | 20uA, 40uA, 200uA, 400uA, 2mA, 4mA, 20mA, 40mA, 0.2A, 1A, 2.5A, 5A, 10A, 20A; max 22A |
|
Load capacity | 20W | |
Adjustable Range | 0-110% FS (1000V not included) | |
Adjustable Fineness | 5×10-5 | |
Stability | ≤0.01% FS /60s (peak-peak value) | |
Accuracy | ±(0.06%RD+0.04%FS) | |
Ripple wave | ≤1% FS | |
Range | 0-200Ω, 200-400Ω, 0-2kΩ, 2kΩ-5kΩ, 0-20kΩ, 20kΩ-50kΩ, 0-100kΩ, 0-200kΩ, 200kΩ-500kΩ, 0-2MΩ, 2MΩ-5MΩ, 10MΩ, 20MΩ |
|
Fineness | 0.02% | |
Range 0-2kΩ, 0-20kΩ, 0-200kΩ | ||
Range 0-2kΩ | Adjustable Range | 0-100%FS |
Accuracy | ±(0.12%RD+0.08%FS) | |
Range 0-200Ω,0-2MΩ | Adjustable Range | 0-100% FS |
Accuracy | ±(0.3%RD+0.2%FS) | |
Range 2kΩ-4kΩ, 20kΩ-40kΩ, 200kΩ-400kΩ | ||
Range 2kΩ-4kΩ | Adjustable Range | 5%-100%FS |
Accuracy | ±(0.12%RD+0.08%FS) | |
Range 200-400Ω, 2MΩ-4MΩ |
Adjustable Range | 5%-100% FS |
Accuracy | ±(0.3%RD+0.2%FS) | |
200A | Accuracy | ±0.2% |
600A | Accuracy | ±0.5% |
1000A | Accuracy | ±1% |
Range | 1kHz, 5kHz, 10kHz, 50kHz, 100kHz, 200kHz, 1000kHz | |
Square wave amplitude | 4.5V | |
Setting accuracy | 5×10-5 | |
Dimension (L×W×H) (mm) | 440x360x160 | |
Weight (kg) | 12 | |
Operating temperature | 20°C±10°C | |
Relative humidity | ≤85%RH |