Customization: | Available |
---|---|
Theory: | Electromagnetic Relay |
Usage: | Single Phase Microcomputor Protection Relay Test S |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Electrical parameters | ||||
---|---|---|---|---|
Rated input power | ||||
AC | 220V±10% 1000VA·50/60Hz or 110V±10% 1000VA·50/60Hz |
|||
Turn on/turn off auxiliary contacts | ||||
Max current | 1A | |||
Max voltage | AC250V or DC120V | |||
AC output | ||||
Range | 0-10A | 0-40A | 0-100A | 0-100A |
No-load Voltage(Min) | 90V | 25V | 10V | 10V |
Full-load Voltage (Min) | 80V | 22V | 8V | |
Full-load Current (Max) | 10A | 40A | 100A | 150A |
AC/DC voltage output | ||||
Range | 0-250V(AC) | 0-300V(DC) | ||
No-load Voltage(Min) | 250V | 320V | ||
Full-load Voltage (Min) | 240V | 250V | ||
Full-load Current (Max) | 3A | 3A | ||
Auxiliary DC voltage output | ||||
Range | 5-120V | 110-220V | ||
Max Voltage | 120V | 220V | ||
Max Current | 0.5A | 0.5A | ||
Auxiliary AC voltage output | ||||
Range | 0-120V | |||
Max voltage | 120V | |||
Max current | 0.5A | |||
Stopwatch | ||||
Range | 0.0000-999999S | |||
Resolution | 0.1mS | |||
Accuracy | ±5 words | |||
Max input voltage (With contact and potential nput) | DC 250V | |||
Ammeter | ||||
Range | Inside 0.000-150.0A Outside 0.000-6.000A(AC or DC) |
|||
Accuracy | 0.50% | |||
Voltmeter | ||||
Range | 0.0-600.0V(AC or DC) | |||
Accuracy | 0.50% | |||
Measuring mode | AC True RMS DC Average value |
|||
Resistor | ||||
Resistance | 0.5Ω-2.5kΩ | |||
Mechanical characteristics | ||||
Dimensions (W×D×H) (mm) | 340×270×260 | |||
Weight | 18kg | |||
Mechanical parameters | ||||
Temperature | -10°C to 40°C | |||
Relative humidity | <80% |