• GF2015 Gfuve High Voltage Primary Current Monitor Recorder Ammeter From 0 to 2000A
  • GF2015 Gfuve High Voltage Primary Current Monitor Recorder Ammeter From 0 to 2000A
  • GF2015 Gfuve High Voltage Primary Current Monitor Recorder Ammeter From 0 to 2000A
  • GF2015 Gfuve High Voltage Primary Current Monitor Recorder Ammeter From 0 to 2000A
  • GF2015 Gfuve High Voltage Primary Current Monitor Recorder Ammeter From 0 to 2000A
  • GF2015 Gfuve High Voltage Primary Current Monitor Recorder Ammeter From 0 to 2000A

GF2015 Gfuve High Voltage Primary Current Monitor Recorder Ammeter From 0 to 2000A

Display: Digital
Installation: Direct Connected
Usage: Multi-Functional Energy Meter, Watt-Hour Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Reactive Energy Meter, Multi-rate Watt-hour Meters
Electric Equipment: Single-phase
Theory: Electronic Meter
Power Meter Connection: Terminal
Customization:
Gold Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
GF2015
Measured Signal
Pulse Peak
Type
Power Meter
Certification
RoHS, ISO, CE
Customized
Customized
Communication Distance(Wireless)
100m
Software Requirements
PC-Linksoftware & Microsoft Excel
Key Words
High Voltage Monitor Recorder
Processor
100 MHz or Higher
RAM
32 MB, 64m Recommended
Model
Recording Ammeter Kit
Use of Position
Outdoor or Indoor
Voltage
69kv,35kv,20kv, 10kv, 6kv
Sensor Opening
up to 2.5 Cm
Weight (Kg)
0.58
Transport Package
Standard Export Box
Specification
ABS+PC
Trademark
GFUVE
Origin
Beijing, China
Production Capacity
5000000pieces/Year

Product Description

GF2015 Gfuve High Voltage Primary Current Monitor Recorder Ammeter From 0 to 2000A

product description
Application
1. Collect and analyze load profiles
2. Easily clamps to the line in seconds
3. Check for load balance
4. Patented open CT sensor with ±1% accuracy
5. 433M communication with no annoying cables to connect
6. Recorded data quickly downloads into the user's PC
7. PC-LinkSoftware interface downloads directly into
Microsoft Excel
8. Generate reports and create graphs for profile analysis
Features
1. The Primary current recorder uses the same sensor technology as the original Rogowski Coil. The True RMS inductive sensor does not use magnetic materials. The opening of the sensor is electronically closed and external currents are electronically rejected.
2. The accuracy, external current reject, and range of currents measured by the patented amp sensor substantially exceed the performance of the best clamp-on sensors. The key feature of the unit is the ability to leave it deployed on the line to record readings every 15 minutes for 90+ days. It easily
attaches to the line with a standard insulating bar. Once on the line, it immediate begins to collect and record the primary current on the line.
3. The Primary current recorder is equipped with a 433M wireless port for communicating the recorded data into the user's PC. The data is downloaded through GF2015S PC-LinkSoftware software, which allows the user to download, view and query the data stored on the Primary current recorder.
4. The housing of the Primary current recorder is made of ABS+PC and is built to operate safely, even in severe utility environments. It is resistant to shock, repels water and is unsusceptible to flame. It also operates within a wide temperature range. The Primary current recorder has the screw insulation bar of installation, which allows it to hang on the line securely in all weather conditions.
5. PC-LinkSoftware is a user-friendly software interface that allows the user to download, view, graph and export data from the Primary current recorder into Microsoft Excel. The data directly transfers from the Primary current recorder into Excel through an 433M Port.
Parameters
Basic parameters  
Recording ammeter kit 3 wireless current sensors (GF2018A, GF2018B, GF2018C)
433 HHT(handheld terminal) or 433M wireless data reader(GF2018R)
PC-LinkSoftware software(GF2018S)
Carrying case
Data recording interval 5min, 10min,15min, 30min;
Time can be set from 1 minute to 60 minutes
Communication distance(wireless) Max 100m
Communication 433M, 868M or 915M (option)
Installation Installation with electricity; Disassemble with electricity
Battery 3.6 volt lithium battery,9000mAh; Battery can be replaced
Software requirements PC-Linksoftware & microsoft Excel
Processor 100 MHz or higher (200 MHz or higher recommended)
RAM 32 MB, 64M recommended
Drive space 15 MB to load software, 10 MB of operating Space
Use of position Outdoor or indoor
Electrical parameters
Range of operation
Voltage 69kV,35kV,20KV, 10kV, 6kV 
Current 1 to 300A
Sensor opening Up to 3.3 cm
Resolution
Amps 1 to 99.9A 0.1A
100 to 300A 1A
Amps accuracy  ±1% of reading plus 2 counts
Frequency 60Hz (57-63 Hz) or 50Hz (47-53 Hz) models available
Mechanical parameters
Weight (kg) 0.48
Environmental conditions
Operating temperature -40°C to 60°C