• Gfuve 1000A Primary Current Injection Test Set
  • Gfuve 1000A Primary Current Injection Test Set
  • Gfuve 1000A Primary Current Injection Test Set
  • Gfuve 1000A Primary Current Injection Test Set
  • Gfuve 1000A Primary Current Injection Test Set
  • Gfuve 1000A Primary Current Injection Test Set

Gfuve 1000A Primary Current Injection Test Set

Application: Electromagnetic Instrument
Power: Electricity
Certification: CE, CCC, ISO9001:2015
Current Output: 0-1100A
LCD Display: With LCD Display
Customized: Customized
Customization:

Contact Supplier

Gold Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
Test-901
Names
Megger Primary Current Injection Test System
Accuracy
0.5%
Function
Circuit Break Test & CT Test
LCD
2.8 Inch Green LCD
1000A Cable Length
6m
Weights
25kg
Applications
Current Transformer Ratio Test
Brand
Gfuve
Transport Package
Standard Export Wooden Box
Specification
1000A class 0.5
Trademark
GFUVE
Origin
Beijing, China
Production Capacity
200PCS/Month

Product Description

GFUVE  Large Current 1000A Primary Current Injection Test Set HV Circuit Breaker Tester
Gfuve 1000A Primary Current Injection Test Set

 

TEST-901 1000a primary current injection test system adopts ARM Chip to control its output process and large capacity of toroidal transformers. It is equipped with LCD display and current meter; it can show primary current value, second current value, turn ratio and the action time. Packing is used as aluminum alloy body with PC panel. TEST-901 is mainly applied to CT turn ratio testing in the power system and contact resistance test which need large current. GFUVE test-901's function is better than Megger products.

Application
Primary current injection testing is utilised in high current/high voltage scenarios found at large electrical installations such as substations. A large current (between 100A and 20,000A depending on system specifications and test requirements) is injected directly on the primary side of the electrical system such as a circuit breaker. The objective of the test is to identify how the system operates under various levels of current load.
Primary injection testing is suitable for testing over-current trip relays attached to a circuit breaker. By injecting the current into the system we can measure if the breaker will trip or fail, and how long the current is live before the circuit is broken.
Circuit breakers can go long periods of time without activation, and failure at the moment of activation can cause catastrophic damage to the electrical system. Circuit breaker testing with primary current injection on a breaker that has not triggered in some time is the best way to recreate the real operating conditions of a current spike.

CT ratio Test
Circuit Breaker test
Resistance Test
Primary current injection test
With timer
With binary input
with 0-6A secondary current measurement meter
6m 1000A current cable

PARAMETERS

Electrical parameters
Accuracy ±0.5%
Power Supply(AC) 220V±10%·25A, 50Hz/60Hz or
110V±10%·50A, 50Hz/60Hz
Current Output (AC) 1000A·5V or 500A·10V
Capacity 5KVA
The current output waveform distortion ≤5%
Dual protection overload electronic protection and software protection
Primary current
Range 0-1100A
Resolution 0.1A
Accuracy <0.5%
Secondary measurement
Range 0-6A
Resolution 0.001A
Accuracy <0.5%
Current duration
1000A range 1000A    2-3minutes
500A      3-6minutes
500A range 500A      2-3minutes
With timer
Range 0.0001~999.99S
Resolution 0.001S
Accuracy <0.5%±5 words
Mechanical parameters
Dimensions (W×D×H) (mm) 430×260×260
Weight(kg) 25
Environmental conditions
Temperature -10°C to 40°C
Relative humidity ≤80%

SELECTION GUIDE

 Model ACCU
RACY
Primary
current
AMMETER
(0-6A)
TIMER POWER INJECTION CURRENT TIME DIMENSION(W×D×H)(mm) WEIGHT REMARK
TEST-901 0.5% 0-1100A YES YES 5KVA 1000A: 2-3min;
500A:3-6min
430×260×260 25KG Integrated structure
TEST-902 0.5% 0-2200A YES OPTIONAL 12KVA 2000A:2-3min;
1000A:3-6min
360×300×295 and 320×300×300 35KG+15KG Fission structure
TEST-903 0.5% 0-3300A YES OPTIONAL 15KVA 3000A:2-3min;
1500A:3-6min
380×350×360 and 340×290×420 48KG+42KG Fission structure
TEST-905 0.5% 0-5500A YES OPTIONAL 25KVA 5000A:2-3min;
2500A:3-6min
430×430×445 and 550×450×600 68KG+55KG Fission structure
 

 

Send your message to this supplier

*From:
*To:
avatar Mr. Andy Huang
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Product Groups

Contact Supplier

Gold Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory
Registered Capital
5000000 RMB
Plant Area