• Current Transformer Test Equipment
  • Current Transformer Test Equipment
  • Current Transformer Test Equipment
  • Current Transformer Test Equipment
  • Current Transformer Test Equipment
  • Current Transformer Test Equipment

Current Transformer Test Equipment

After-sales Service: Yes
Warranty: Yes
Accuracy: 0.2% or 0.5%
Primary Current Output: 1000A
Voltage Output: 2500V
CT Ratio: 25000A/5A(5000A/1A)
Customization:
Gold Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
GF106T
PT Ratio
1-500kv
Weight
23kg
Standards
IEC60044-1, IEC60044-6, IEC61869-2-2012
Transport Package
Standard Export Carton
Specification
CE, ISO9001: 2008, IEC
Trademark
GFUVE
Origin
Beijing, China
Production Capacity
200set/Month

Product Description

GF106T PORTABLE Current transformer test equipment
 Current Transformer Test Equipment
Current Transformer Test Equipment
Current Transformer Test Equipment
It is mainly used for field testing of P class CT and PT. The test items mainly include excitation characteristic, transformation ratio, polarity, degauss, 5% and 10% error curves, secondary circuit check, withstand test of power frequency alternating current and secondary load. Adopting LCD, self-equipped mini type printer supporting field printing; supporting to use USB flash disk to dump data, with simple and convenient operation.

MAIN FUNCTIONS
I. Current Transformer (CT)II. Voltage Transformer (PT)
1. Magnetization curve 1. Excitation characteristic test
2. Transformation ratio test 2. Transformation ratio test
3. Polarity 3. Polarity 
4. 5% and 10% error curve 4. Withstand test of power frequency alternating current
5. Current Injecting 5. Degauss
6. Degauss 6. Calculation of knee point value
7. Withstand test of power frequency alternating   current 7. Actual secondary load test
8. Automatic calculation of excitation knee 
point value
8. Resistance test
9. Actual secondary load test
10. Resistance test

PARAMETERS
Electrical parametersElectrical parameters - continuedStandardsMechanical parametersEnvironmental conditions
Accuracy 0.2%, 0.5%
Power supply AC 220V±10% or AC 110V±10%, 50/60Hz
Excitation voltage output 0-2500Vrms, 
Excitation current output 0-5Arms (20A peak-value)
Large current output 0-1000A
Accuracy ≤0.5% (0.2%RD+0.3%RG)
Secondary winding DC resistance measurement Range 0.1-300Ω
Accuracy ≤0.5% (0.2%RD+0.3%RG)
Secondary actual load measurement Range 5VA-1000VA
Accuracy ≤0.5% (0.2%RD+0.3%RG)±0.1VA
CT/PT phase error measurement Accuracy ±4min
Resolution 0.01min
CT ratio error measurement Range ≤25000A/5A(5000A/1A)
Accuracy ≤0.5%
PT ratio error measurement Range 1-500KV
Accuracy ≤0.5%
Reference standards GB1207-2006, GB1208-2006, GB16847-1997 
IEC60044-1, IEC60044-6, IEC61869-2-2012
Safety standards GB 4793.1-2007
EMC EMC standard 89/336/EEC
FCC Subpart B of Part 15 Class A
IEC 1000-4-2 /3 /4 /6
Overall dimension (L x W x H) (mm) 400 x 250 x 250 
Weight (kg)   ≤22
Relative humidity    90RH%
Operating temperature -10°C to +40°C
Altitude ≤1000m
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now