GF302D3portable Three Phase Energy Meter Test Analyzer
Product Details
| Customization: | Available |
|---|---|
| After-sales Service: | Yes |
| Warranty: | 3 Years |
Secured Trading Service
Diamond Member Since 2013
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Address
Bldg. 2-1111, Joy Mansion, No. 99 Chaoyang North Road, Chaoyang District, Beijing, China
International Commercial Terms(Incoterms)
FOB, CIF, FCA, EXW
Terms of Payment
LC, T/T, PayPal, Western Union
Find Similar Products
Basic Info.
- Accuracy
- 0.02%
- Current Output (AC)
- 25va or 50va
- Capacity
- 5kVA
- Range
- 0-1100A
- Resolution
- 0.1A
- with Timer
- 0.0001 to 999.999s
- Standard
- IEC62053-21,22,23; IEC60736
- Communication Port
- RS232
- Weight(Kg)
- 18kg
- Cable
- Length 2X6m, 70mm²
- Current Duration
- 1000A 2-3minutes
- Continuous Output
- 400A
- Operating Temperature
- -10°C to +40°C
- Storage Temperature
- -40°C to 70°C
- The Current Output Waveform Distortion
- ≤5%
- Transport Package
- Plywood Box
- Specification
- 445 x 460 x 158mm
- Trademark
- GFUVE
- Origin
- China
- HS Code
- 903033
- Production Capacity
- 5000sets/Year
Product Description
GF302D3PORTABLE THREE PHASE ENERGY METER TEST BENCH
The GF302D3 portable three phase energy meter test bench consists of an integrated three phase 120A current source and 600V voltage source and a class 0.02 three phase electronic reference standard meter.
The energy meter test bench is particularly designed for analysis of complete metering installations and local mains conditions. The meter test bench offers high functionality combined with an excellent menu guided operation via built-in thirty keys and colored 7" touch LCD-display. It can auto & manual test all kinds of energy meter error. Using on site or in the laboratory. It can preset a variety of test schemes for testing energy meter.


PARAMETERS
| Electrical parameters | |
|---|---|
| Accuracy | 0.02%, 0.05% |
| Power supply | Single phase AC 85-265V, frequency 50/60Hz. |
| AC voltage output | |
| Range (U1, U2, U3) | 57.7V, 100V, 220V, 380V; max 500V or 69.3V, 120V, 240V, 480V (optional); max 600V |
| Adjustment range | (0-120)%RG(1) |
| Adjustment fineness | 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional. |
| Stability | 0.01%/120s |
| Distortion | 0.2% (Non-capacitive load) |
| Output load | each phase 25VA or 50VA |
| Accuracy | 0.05%RG or 0.02%RG |
| AC current output | |
| Range (I1, I2, I3) | 200mA, 1A, 5A, 20A, 100A; max 120A |
| Adjustment range | (0-120)%RG |
| Adjustment fineness | 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional. |
| Stability | <0.01%/120s |
| Distortion | ≤0.2% (Non-capacitive load) |
| Output load | 50VA or 100VA or 200VA |
| Accuracy | 0.05%RG or 0.02%RG |
| Power output | |
| Active power output stability | <0.01%RG/120s |
| Reactive power output stability | <0.02%RG/120s |
| Active power measuring accuracy | 0.05%RG or 0.02%RG |
| Reactive power measuring accuracy | 0.1%RG |
| Apparent power measuring accuracy | 0.05%RG or 0.02%RG |
| Phase output | |
| Output adjustment range | 0°>-359.999° |
| Output adjustment fineness | 10, 1, 0.1, 0.01 as optional. |
| Resolution | 0.01° |
| Accuracy | 0.02° |
| Power factor | |
| Adjustment range | -1 ~ 0 ~ 1 |
| Resolution | 0.0001 |
| Measurement accuracy | 0.0005 |
| Frequency output | |
| Adjustment range | 40Hz-70Hz |
| Output adjustment fineness | 5Hz, 1Hz, 0.1Hz, 0.01Hz as optional. |
| Resolution | 0.001Hz |
| Accuracy | 0.002Hz |
| Voltage/Current/Harmonic setting output | |
| Harmonic number | 2-63times |
| Harmonic content | 0-40% |
| Harmonic phase | 0-359.99 |
| Harmonic setting accuracy | (10%±0.1%)RD(2) |
| Power energy measurement error | |
| Active power energy | 0.05%RG or 0.02%RG |
| Reactive power energy | 0.1%RG |
| Power pulse output | |
| Power pulse type | Active pulse, reactive pulse |
| Active power pulse output | 5V, 10mA |
| Power pulse input | |
| Energy pulse type | Support active and reactive pulse, the highest frequency power pulse input is 200K. |
| Communication port | |
| Communication port | RS232, USB2.0 |
| Standard | |
| Standard | IEC62053-21,22,23; IEC60736; ANSI C12.20-2002; JJG 597-2005; JJG596-2012; JJG 1085-2013; JJF 68-2019; DL/T 826-2002; DL/T 1478-2015; DL/T 448-2016 |
| Safety | |
| Isolation protection | IEC61010-1: 2001 |
| Measurement category | 300V CAT III, 600V CAT II |
| Degree of protection | IP20 |
| Declaration of conformity | CE & CNAS certified |
| Mechanical parameters | |
| Dimensions (W×D×H)(mm) | 445 x 460 x 158 |
| Weight (kg) | 18 |
| Environmental conditions | |
| Ambient temperature | -10°C to +40°C |
| Relative humidity | 35%-85% |
| (1) RG means range, the same as below; (2) RD means the setted harmonic content, harmonic can be a single output, also multiple output. |
|