• 0.2 High Quality Portable CT PT Analyzer
  • 0.2 High Quality Portable CT PT Analyzer
  • 0.2 High Quality Portable CT PT Analyzer
  • 0.2 High Quality Portable CT PT Analyzer
  • 0.2 High Quality Portable CT PT Analyzer
  • 0.2 High Quality Portable CT PT Analyzer

0.2 High Quality Portable CT PT Analyzer

Application: Electromagnetic Instrument
Power: Electricity
Certification: FDA, CE, IAF, CCC
Voltage Output: 0-2500V
Current Output: 0-1000A
LCD Display: With LCD Display
Customization:

Contact Supplier

Gold Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
GF106T
Customized
Customized
Keyword
0.2 CT PT Analyzer
Model
Portable CT PT Analyzer
GF106t
0.2 Current Transformer Tester
Accuracy
0.2%, 0.5%
CT Ratio
25000A/5A(5000A/1A)
PT Ratio
1-500kv
Phase Error
4min
Ratio Error
0.5%
Burden
5va-1000va
Types
CT Analyzer
Transport Package
Standard Export Wooden Box
Specification
GF106T, 0.2%, 1000A/2500V
Trademark
GFUVE
Origin
Beijing, China
Production Capacity
10000pieces/Month

Product Description

0.2 High Quality Portable CT PT analyzer
It is mainly used for field testing of P class CT and PT. The test items mainly include excitation characteristic, transformation ratio, polarity, degauss, 5% and 10% error curves, secondary circuit check, withstand test of power frequency alternating current and secondary load. Adopting LCD, self-equipped mini type printer supporting field printing; supporting to use USB flash disk to dump data, with simple and convenient operation.
Main functions
I. Current Transformer (CT) II. Voltage Transformer (PT)
1. Magnetization curve 1. Excitation characteristic test
2. Transformation ratio test 2. Transformation ratio test
3. Polarity 3. Polarity 
4. 5% and 10% error curve 4. Withstand test of power frequency alternating current
5. Current Injecting 5. Degauss
6. Degauss 6. Calculation of knee point value
7. Withstand test of power frequency alternating   current 7. Actual secondary load test
8. Automatic calculation of excitation knee
point value
8. Resistance test
9. Actual secondary load test
10. Resistance test
Parameters
Electrical parameters
Accuracy 0.2%, 0.5%
Power supply AC 220V±10% or AC 110V±10%, 50/60Hz
Excitation voltage output 0-2500Vrms, 
Excitation current output 0-5Arms (20A peak-value)
Large current output 0-1000A
Electrical parameters - continued
Accuracy ≤0.5% (0.2%RD+0.3%RG)
Secondary winding DC resistance measurement Range 0.1-300Ω
Accuracy ≤0.5% (0.2%RD+0.3%RG)
Secondary actual load measurement Range 5VA-1000VA
Accuracy ≤0.5% (0.2%RD+0.3%RG)±0.1VA
CT/PT phase error measurement Accuracy ±4min
Resolution 0.01min
CT ratio error measurement Range ≤25000A/5A(5000A/1A)
Accuracy ≤0.5%
PT ratio error measurement Range 1-500KV
Accuracy ≤0.5%
Standards
Reference standards GB1207-2006, GB1208-2006, GB16847-1997
IEC60044-1, IEC60044-6, IEC61869-2-2012
Safety standards GB 4793.1-2007
EMC EMC standard 89/336/EEC
FCC Subpart B of Part 15 Class A
IEC 1000-4-2 /3 /4 /6
Mechanical parameters
Overall dimension (L x W x H) (mm) 400 x 250 x 250 
Weight (kg)   ≤22
Environmental conditions
Relative humidity    90RH%
Operating temperature -10°C to +40°C
Altitude ≤1000m
0.2 High Quality Portable CT PT Analyzer

Send your message to this supplier

*From:
*To:
avatar Mr. Andy Huang
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Product Groups

Contact Supplier

Gold Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory
Registered Capital
5000000 RMB
Plant Area