• Class 0.05 120A 560V Portable Three Phase Power Calibrator
  • Class 0.05 120A 560V Portable Three Phase Power Calibrator
  • Class 0.05 120A 560V Portable Three Phase Power Calibrator
  • Class 0.05 120A 560V Portable Three Phase Power Calibrator
  • Class 0.05 120A 560V Portable Three Phase Power Calibrator
  • Class 0.05 120A 560V Portable Three Phase Power Calibrator

Class 0.05 120A 560V Portable Three Phase Power Calibrator

After-sales Service: 24 Hours Service
Warranty: 3 Years Warranty
Application: Electromagnetic Instrument
Power: Electricity
Certification: FDA, CE, IAF, CCC
Voltage Output: 0-560V
Customization:
Gold Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
GF302D1
Current Output
0-120A
LCD Display
With LCD Display
Customized
Non-Customized
Class
0.05
GF302D1
Portable Three Phase Power Calibrator
Function1
Current Source
Function2
Voltage Source
Function3
Power Calibrator
Phase Angle
0-360.000
Frequency
40-70Hz
Transport Package
Standard Export Wooden Box
Specification
GF302D1 0.05% 120A/560V
Trademark
GFUVE
Origin
Beijing China
Production Capacity
200sets/Month

Product Description

GF302D1 class 0.05 120A 560V portable three phase power calibrator

The GF302D1 three phase portable power calibrator consists of an integrated three phase current and voltage source(up to 500V/120A or 500V/20A) and built-in three-phase electronic reference standard of accuracy class 0.05%. Characteristic features of the GF302D1 are its wide measuring range, high accuracy and high tolerance to unwanted external influences. The equipment offers high functionality combined with an excellent menu guided operation via built-in keyboards and colored 7" touch LCD-display.
Class 0.05 120A 560V Portable Three Phase Power Calibrator
Class 0.05 120A 560V Portable Three Phase Power Calibrator
Class 0.05 120A 560V Portable Three Phase Power Calibrator
 

FEATURES

  • Accuracy class 0.05
  • 0-20A/0-500V, 0-120A/0-500V
  • Start testing and creep testing
  • Reference standard and power source integrated
  • Test by automatic or manual
  • 7 inch TFT touch screen
  • Weight light 15Kg
  • Recorder 500 sets energy meter data
  • Overload, short circuit, open circuit protection

PARAMETERS

Electrical parameters  
Accuracy 0.05%, 0.1%
Power Supply One Phase AC 100-265V, frequency 50/60Hz.
AC Voltage Output  
Range(U1,U2,U3) 57.7V, 100V, 220V, 380V
or 69.3V, 120V, 240V, 480V( optional)
Adjustment range (0-120)%RG(1)
Adjustment fineness 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional.
Stability 0.01%/120s
Distortion 0.3% (Non-capacitive load)
Output load each phase 30VA
Measuring accuracy 0.05%RG
AC Current Output  
Range(I1,I2,I3) 200mA, 1A, 5A, 20A, 100A(optional)
Adjustment range (0-120)%RG
Adjustment fineness 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional.
Stability <0.01%/120s
Distortion ≤0.3% (Non-capacitive load)
Output load 30VA
Accuracy 0.05%RG
Power Output   
Active power output stability <0.01%RG/120s
Reactive power output stability <0.02%RG/120s
Active power measuring accuracy  0.05%RG
Reactive power measuring accuracy 0.1%RG
Phase Output   
Output adjustment range 0°-359.999°
Output adjustment fineness 10, 1, 0.1, 0.01 as optional.
Resolution 0.01°
Accuracy 0.03°
Power Factor  
Adjustment range -1 ~ 0 ~ 1
Resolution 0.0001
Measurement accuracy 0. 0005
Frequency Output   
Adjustment range 40Hz-70Hz
Output adjustment fineness 5Hz, 1Hz, 0.1Hz, 0.01Hz as optional.
Resolution 0.001Hz
Accuracy 0.005Hz
Voltage /Current/Harmonic Setting  
Harmonic number 2-51times
Harmonic content 0-40%
Harmonic phase 0-359.99
Harmonic setting accuracy (10%±0.1%)RD(2)
Power Energy Measurement Error  
Active power energy 0.05%RG
Reactive power energy 0.1%RG
Power Pulse Output   
Power pulse type active pulse, reactive pulse
Active power pulse output  5V,  10mA
Power Pulse Input  
Energy pulse type support active and reactive pulse, the highest frequency power pulse input is 180K.
Mechanical parameters  
Dimensions (W×D×H) (mm) 495x390x195
Weight (kg) 15
Environmental conditions
Ambient temperature -10°C to +50°C
Relative humidity 35%-85%
(1) RG means range, the same as below;
(2) RD means the setted harmonic content, harmonic can be a single output, also multiple output.

SELECTION GUIDE

NO. Accuracy Voltage range Current Range Weight
302D112001 0.10% 0-500V 0-120A 22KG
302D1120005 0.05% 0-500V 0-120A 22KG
302D11201 0.10% 0-500V 0-12A 15KG
302D112005 0.05% 0-500V 0-12A 15KG
302D12401 0.10% 0-500V 0-24A 16KG
302D124005 0.05% 0-500V 0-24A 16KG

 