• Single Phase AC Current/Voltage Transducer 4-20mA 0.2%
  • Single Phase AC Current/Voltage Transducer 4-20mA 0.2%
  • Single Phase AC Current/Voltage Transducer 4-20mA 0.2%
  • Single Phase AC Current/Voltage Transducer 4-20mA 0.2%
  • Single Phase AC Current/Voltage Transducer 4-20mA 0.2%
  • Single Phase AC Current/Voltage Transducer 4-20mA 0.2%

Single Phase AC Current/Voltage Transducer 4-20mA 0.2%

Kind: Digital Transmitter
Type: AC Transmitter
Phase: Single
Wire-Assembly Type: Two-wire Transmitter
Accuracy Grade: 0.2G
Certification: CE
Customization:
Gold Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
FUD-I/U
Customized
Customized
Usage
Current Transducer
Transport Package
Standard Export Carton
Specification
CE, ISO9001: 2008, IEC
Trademark
GFUVE
Origin
Beijing, China
Production Capacity
10000PCS/Month

Product Description


FUD-I/U SINGLE PHASE AC VOLTAGE CURRENT TRANSDUCER
Changing the measured AC current/voltage to the DC current/voltage output according to the linear scale Excellent temperature characteristic and good working stability Configuration compactness and briefness.
Single Phase AC Current/Voltage Transducer 4-20mA 0.2%


FEATURES
Single phase current / voltage transducer
AC current / voltage transducer
Accuracy class can reach 0.2%
AC input range can be customized
DC output range can be customized
 
MODEL DESCRIPTION

FUD-Type-Input-Power Supply-Output
Type I: Single phase AC current transducer
U: Single phase AC voltage transducer
Ir: Single phase AC real RMS current transducer
Ur: Single phase AC real RMS voltage transducer
AC input A1: 0-1A, A2: 0-5A, A3: 0-10A.
V0: 0-70V, V1: 0-120V, V2: 0-250V,
V3: 0-300V, V4: 0-450V, V5: 0-500V.
Power supply P1: AC110V±10%, P2: AC220V±15%, P3: AC110V-330V.
DC output O1: 0-5V, O2: 1-5V, O3: 0-20mA, O4: 4-20mA, O5: RS485
Example 1: FUD-I-A2-P2-O4
FUD series single phase AC current transducer Input: AC0-5A
Power supply: AC220V±15%
Output: DC4-20mA
Example 2: FUD-Ur-V3-P2-O4
FUD series single phase AC real RMS voltage transducer Input: AC 0-300V
Power supply: AC220V±15%
Output: DC4-20mA
Please check the type, input range, output range and power supply when your order the product.

TECHNICAL INDEX

Technical Index
Standard GB/T 13850-1998, IEC688:1992
Accuracy 0.2%, 0.5%
Consumption ≤3VA
Accuracy drift Annual variation < 0.2%
Insulation voltage AC 2kV/min.1mA (Between input- output / power)
Insulation resistance ≥20MΩ (DC500V)
Surge voltage 5KV (Peak value), 1.2/50μs
Response time ≤350ms
Input range AC 0-10A ,AC 0-500V(Option), 50/60Hz
Absorbed power <0.5VA/450V, <0.2VA/100V, <0.1VA/5A
Overload Current: 2 times continuous, 30 times /1s; 
Voltage: 2 times continuous
Load resistance Current output: RL≤550Ω
Voltage output: RL≥2kΩ
Working environment Temperature: -10 to +50ºC
RH: 20-90%, without condensation
Storage conditions Temperature: -40 to +70ºC
RH: 20-95%, without condensation
Installation 35mm DIN sliding-way or M4 screws
Dimension 55mm x 75mm x 120mm

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now